Skip to main content

Showing 1–3 of 3 results for author: Labussière, M

Searching in archive eess. Search in all archives.
.
  1. Blur aware metric depth estimation with multi-focus plenoptic cameras

    Authors: Mathieu Labussière, Céline Teulière, Omar Ait-Aider

    Abstract: While a traditional camera only captures one point of view of a scene, a plenoptic or light-field camera, is able to capture spatial and angular information in a single snapshot, enabling depth estimation from a single acquisition. In this paper, we present a new metric depth estimation algorithm using only raw images from a multi-focus plenoptic camera. The proposed approach is especially suited… ▽ More

    Submitted 8 August, 2023; originally announced August 2023.

    Comments: 21 pages, 12 Figures, 3 Tables

  2. Leveraging blur information for plenoptic camera calibration

    Authors: Mathieu Labussière, Céline Teulière, Frédéric Bernardin, Omar Ait-Aider

    Abstract: This paper presents a novel calibration algorithm for plenoptic cameras, especially the multi-focus configuration, where several types of micro-lenses are used, using raw images only. Current calibration methods rely on simplified projection models, use features from reconstructed images, or require separated calibrations for each type of micro-lens. In the multi-focus configuration, the same part… ▽ More

    Submitted 9 November, 2021; originally announced November 2021.

    Comments: arXiv admin note: text overlap with arXiv:2004.07745

  3. Blur Aware Calibration of Multi-Focus Plenoptic Camera

    Authors: Mathieu Labussière, Céline Teulière, Frédéric Bernardin, Omar Ait-Aider

    Abstract: This paper presents a novel calibration algorithm for Multi-Focus Plenoptic Cameras (MFPCs) using raw images only. The design of such cameras is usually complex and relies on precise placement of optic elements. Several calibration procedures have been proposed to retrieve the camera parameters but relying on simplified models, reconstructed images to extract features, or multiple calibrations whe… ▽ More

    Submitted 16 April, 2020; originally announced April 2020.

    Comments: 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works