-
Tensorial tomographic Fourier Ptychography with applications to muscle tissue imaging
Authors:
Shiqi Xu,
Xiang Dai,
Paul Ritter,
Kyung Chul Lee,
Xi Yang,
Lucas Kreiss,
Kevin C. Zhou,
Kanghyun Kim,
Amey Chaware,
Jadee Neff,
Carolyn Glass,
Seung Ah Lee,
Oliver Friedrich,
Roarke Horstmeyer
Abstract:
We report Tensorial tomographic Fourier Ptychography (ToFu), a new non-scanning label-free tomographic microscopy method for simultaneous imaging of quantitative phase and anisotropic specimen information in 3D. Built upon Fourier Ptychography, a quantitative phase imaging technique, ToFu additionally highlights the vectorial nature of light. The imaging setup consists of a standard microscope equ…
▽ More
We report Tensorial tomographic Fourier Ptychography (ToFu), a new non-scanning label-free tomographic microscopy method for simultaneous imaging of quantitative phase and anisotropic specimen information in 3D. Built upon Fourier Ptychography, a quantitative phase imaging technique, ToFu additionally highlights the vectorial nature of light. The imaging setup consists of a standard microscope equipped with an LED matrix, a polarization generator, and a polarization-sensitive camera. Permittivity tensors of anisotropic samples are computationally recovered from polarized intensity measurements across three dimensions. We demonstrate ToFu's efficiency through volumetric reconstructions of refractive index, birefringence, and orientation for various validation samples, as well as tissue samples from muscle fibers and diseased heart tissue. Our reconstructions of muscle fibers resolve their 3D fine-filament structure and yield consistent morphological measurements compared to gold-standard second harmonic generation scanning confocal microscope images found in the literature. Additionally, we demonstrate reconstructions of a heart tissue sample that carries important polarization information for detecting cardiac amyloidosis.
△ Less
Submitted 13 May, 2023; v1 submitted 8 May, 2023;
originally announced May 2023.
-
Digital staining in optical microscopy using deep learning -- a review
Authors:
Lucas Kreiss,
Shaowei Jiang,
Xiang Li,
Shiqi Xu,
Kevin C. Zhou,
Alexander Mühlberg,
Kyung Chul Lee,
Kanghyun Kim,
Amey Chaware,
Michael Ando,
Laura Barisoni,
Seung Ah Lee,
Guoan Zheng,
Kyle Lafata,
Oliver Friedrich,
Roarke Horstmeyer
Abstract:
Until recently, conventional biochemical staining had the undisputed status as well-established benchmark for most biomedical problems related to clinical diagnostics, fundamental research and biotechnology. Despite this role as gold-standard, staining protocols face several challenges, such as a need for extensive, manual processing of samples, substantial time delays, altered tissue homeostasis,…
▽ More
Until recently, conventional biochemical staining had the undisputed status as well-established benchmark for most biomedical problems related to clinical diagnostics, fundamental research and biotechnology. Despite this role as gold-standard, staining protocols face several challenges, such as a need for extensive, manual processing of samples, substantial time delays, altered tissue homeostasis, limited choice of contrast agents for a given sample, 2D imaging instead of 3D tomography and many more. Label-free optical technologies, on the other hand, do not rely on exogenous and artificial markers, by exploiting intrinsic optical contrast mechanisms, where the specificity is typically less obvious to the human observer. Over the past few years, digital staining has emerged as a promising concept to use modern deep learning for the translation from optical contrast to established biochemical contrast of actual stainings. In this review article, we provide an in-depth analysis of the current state-of-the-art in this field, suggest methods of good practice, identify pitfalls and challenges and postulate promising advances towards potential future implementations and applications.
△ Less
Submitted 14 March, 2023;
originally announced March 2023.
-
Parallelized computational 3D video microscopy of freely moving organisms at multiple gigapixels per second
Authors:
Kevin C. Zhou,
Mark Harfouche,
Colin L. Cooke,
Jaehee Park,
Pavan C. Konda,
Lucas Kreiss,
Kanghyun Kim,
Joakim Jönsson,
Jed Doman,
Paul Reamey,
Veton Saliu,
Clare B. Cook,
Maxwell Zheng,
Jack P. Bechtel,
Aurélien Bègue,
Matthew McCarroll,
Jennifer Bagwell,
Gregor Horstmeyer,
Michel Bagnat,
Roarke Horstmeyer
Abstract:
To study the behavior of freely moving model organisms such as zebrafish (Danio rerio) and fruit flies (Drosophila) across multiple spatial scales, it would be ideal to use a light microscope that can resolve 3D information over a wide field of view (FOV) at high speed and high spatial resolution. However, it is challenging to design an optical instrument to achieve all of these properties simulta…
▽ More
To study the behavior of freely moving model organisms such as zebrafish (Danio rerio) and fruit flies (Drosophila) across multiple spatial scales, it would be ideal to use a light microscope that can resolve 3D information over a wide field of view (FOV) at high speed and high spatial resolution. However, it is challenging to design an optical instrument to achieve all of these properties simultaneously. Existing techniques for large-FOV microscopic imaging and for 3D image measurement typically require many sequential image snapshots, thus compromising speed and throughput. Here, we present 3D-RAPID, a computational microscope based on a synchronized array of 54 cameras that can capture high-speed 3D topographic videos over a 135-cm^2 area, achieving up to 230 frames per second at throughputs exceeding 5 gigapixels (GPs) per second. 3D-RAPID features a 3D reconstruction algorithm that, for each synchronized temporal snapshot, simultaneously fuses all 54 images seamlessly into a globally-consistent composite that includes a coregistered 3D height map. The self-supervised 3D reconstruction algorithm itself trains a spatiotemporally-compressed convolutional neural network (CNN) that maps raw photometric images to 3D topography, using stereo overlap redundancy and ray-propagation physics as the only supervision mechanism. As a result, our end-to-end 3D reconstruction algorithm is robust to generalization errors and scales to arbitrarily long videos from arbitrarily sized camera arrays. The scalable hardware and software design of 3D-RAPID addresses a longstanding problem in the field of behavioral imaging, enabling parallelized 3D observation of large collections of freely moving organisms at high spatiotemporal throughputs, which we demonstrate in ants (Pogonomyrmex barbatus), fruit flies, and zebrafish larvae.
△ Less
Submitted 19 January, 2023;
originally announced January 2023.
-
Imaging across multiple spatial scales with the multi-camera array microscope
Authors:
Mark Harfouche,
Kanghyun Kim,
Kevin C. Zhou,
Pavan Chandra Konda,
Sunanda Sharma,
Eric E. Thomson,
Colin Cooke,
Shiqi Xu,
Lucas Kreiss,
Amey Chaware,
Xi Yang,
Xing Yao,
Vinayak Pathak,
Martin Bohlen,
Ron Appel,
Aurélien Bègue,
Clare Cook,
Jed Doman,
John Efromson,
Gregor Horstmeyer,
Jaehee Park,
Paul Reamey,
Veton Saliu,
Eva Naumann,
Roarke Horstmeyer
Abstract:
This article experimentally examines different configurations of a novel multi-camera array microscope (MCAM) imaging technology. The MCAM is based upon a densely packed array of "micro-cameras" to jointly image across a large field-of-view at high resolution. Each micro-camera within the array images a unique area of a sample of interest, and then all acquired data with 54 micro-cameras are digit…
▽ More
This article experimentally examines different configurations of a novel multi-camera array microscope (MCAM) imaging technology. The MCAM is based upon a densely packed array of "micro-cameras" to jointly image across a large field-of-view at high resolution. Each micro-camera within the array images a unique area of a sample of interest, and then all acquired data with 54 micro-cameras are digitally combined into composite frames, whose total pixel counts significantly exceed the pixel counts of standard microscope systems. We present results from three unique MCAM configurations for different use cases. First, we demonstrate a configuration that simultaneously images and estimates the 3D object depth across a 100 x 135 mm^2 field-of-view (FOV) at approximately 20 um resolution, which results in 0.15 gigapixels (GP) per snapshot. Second, we demonstrate an MCAM configuration that records video across a continuous 83 x 123 mm^2 FOV with two-fold increased resolution (0.48 GP per frame). Finally, we report a third high-resolution configuration (2 um resolution) that can rapidly produce 9.8 GP composites of large histopathology specimens.
△ Less
Submitted 28 February, 2023; v1 submitted 30 November, 2022;
originally announced December 2022.
-
Transient motion classification through turbid volumes via parallelized single-photon detection and deep contrastive embedding
Authors:
Shiqi Xu,
Wenhui Liu,
Xi Yang,
Joakim Jönsson,
Ruobing Qian,
Paul McKee,
Kanghyun Kim,
Pavan Chandra Konda,
Kevin C. Zhou,
Lucas Kreiß,
Haoqian Wang,
Edouard Berrocal,
Scott Huettel,
Roarke Horstmeyer
Abstract:
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy an…
▽ More
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed Classifying Rapid decorrelation Events via Parallelized single photon dEtection (CREPE)}, a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a $32\times32$ pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1-0.4s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to noninvasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.
△ Less
Submitted 12 June, 2022; v1 submitted 4 April, 2022;
originally announced April 2022.
-
Imaging dynamics beneath turbid media via parallelized single-photon detection
Authors:
Shiqi Xu,
Xi Yang,
Wenhui Liu,
Joakim Jonsson,
Ruobing Qian,
Pavan Chandra Konda,
Kevin C. Zhou,
Lucas Kreiss,
Qionghai Dai,
Haoqian Wang,
Edouard Berrocal,
Roarke Horstmeyer
Abstract:
Noninvasive optical imaging through dynamic scattering media has numerous important biomedical applications but still remains a challenging task. While standard diffuse imaging methods measure optical absorption or fluorescent emission, it is also well-established that the temporal correlation of scattered coherent light diffuses through tissue much like optical intensity. Few works to date, howev…
▽ More
Noninvasive optical imaging through dynamic scattering media has numerous important biomedical applications but still remains a challenging task. While standard diffuse imaging methods measure optical absorption or fluorescent emission, it is also well-established that the temporal correlation of scattered coherent light diffuses through tissue much like optical intensity. Few works to date, however, have aimed to experimentally measure and process such temporal correlation data to demonstrate deep-tissue video reconstruction of decorrelation dynamics. In this work, we utilize a single-photon avalanche diode (SPAD) array camera to simultaneously monitor the temporal dynamics of speckle fluctuations at the single-photon level from 12 different phantom tissue surface locations delivered via a customized fiber bundle array. We then apply a deep neural network to convert the acquired single-photon measurements into video of scattering dynamics beneath rapidly decorrelating tissue phantoms. We demonstrate the ability to reconstruct images of transient (0.1-0.4s) dynamic events occurring up to 8 mm beneath a decorrelating tissue phantom with millimeter-scale resolution, and highlight how our model can flexibly extend to monitor flow speed within buried phantom vessels.
△ Less
Submitted 12 June, 2022; v1 submitted 3 July, 2021;
originally announced July 2021.