-
A Data-Driven Policy for Addressing Deployability Issue of FMM FRPs: Resources Qualification and Deliverability
Authors:
Mohammad Ghaljehei,
Mojdeh Khorsand
Abstract:
Intensified netload uncertainty and variability led to the concept of a new market product, flexible ram** product (FRP). The main goal of FRP is to enhance the generation dispatch flexibility inside real-time (RT) markets to mitigate energy imbalances due to ramp capability shortage. Generally, the FRP requirements are based on system-wide or proxy requirements, so the effect of FRP awards on t…
▽ More
Intensified netload uncertainty and variability led to the concept of a new market product, flexible ram** product (FRP). The main goal of FRP is to enhance the generation dispatch flexibility inside real-time (RT) markets to mitigate energy imbalances due to ramp capability shortage. Generally, the FRP requirements are based on system-wide or proxy requirements, so the effect of FRP awards on the transmission line constraints is not considered. This can lead to FRP deployability issues in RT operation. This paper proposes a new FRP design based on a datadriven policy incorporating ram** response factor sets to address FRP deployability issue. First, a data-mining algorithm is performed to predict the ramp-qualified generators to create the data-driven policy. Then, the FRP awards are assigned to these units while considering effects of post-deployment of FRPs on the transmission line limits. Finally, the proposed data-driven policy is tested against proxy policy through an out-of-sample validation phase that (i) mimics the RT operation of the CAISO, and (ii) represents the expensive ad-hoc actions needed for procuring additional ram** capability to follow realized netload changes. The results show the effectiveness of the proposed data-driven policy from reliability and economic points of view
△ Less
Submitted 15 August, 2023;
originally announced August 2023.
-
A SOCP-based ACOPF for Operational Scheduling of Three-phase Unbalanced Distribution Systems and Coordination of PV Smart Inverters
Authors:
Mingyue He,
Zahra Soltani,
Mohammad Ghaljehei,
Masoud Esmaili,
Shanshan Ma,
Mengxi Chen,
Mojdeh Khorsand,
Raja Ayyanar,
Vijay Vittal
Abstract:
The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone progra…
▽ More
The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone programming (SOCP)-based AC optimal power flow (ACOPF) model for three-phase unbalanced distribution net-works, including smart inverters and Volt-VAr controller (VVC) devices. Reactive power-voltage (Q-V) characteristics of smart inverters of solar photovoltaic (PV) units are also modeled. More-over, the settings of Q-V characteristics of VVC are co-optimized within the proposed ACOPF, considering the allowable range of the IEEE 1547-2018 standard. Furthermore, dynamic analyses are conducted to verify the stability of optimal settings of VVC. The proposed models are tested on an actual 1747-node primary distribution feeder in Arizona. The results illustrate the effective-ness of the proposed ACOPF for unbalanced systems in provid-ing a global optimal solution while capturing the non-linearity and non-convexity of ACOPF. By co-optimizing settings, system operation is improved due to the flexibility of adjusting reactive power output from PV units with VVC. The time-domain simu-lations show that the optimal settings result in a stable system
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
Optimal Placement of PV Smart Inverters with Volt-VAr Control in Electric Distribution Systems
Authors:
Mengxi Chen,
Shanshan Ma,
Zahra Soltani,
Raja Ayyanar,
Vijay Vittal,
Mojdeh Khorsand
Abstract:
The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capa…
▽ More
The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capability for distribution systems with high photovoltaic (PV) penetration to mitigate voltage violation issues. The proposed optimization strategy enables a planningstage guide for upgrading the existing PV inverters to smart inverters with Volt-VAr capability while considering the operationstage characteristics of the Volt-VAr control. One advantage of this planning strategy is that it utilizes the local control capability of the smart inverter that requires no communication, thus avoiding issues related to communication delays and failures. Another advantage is that the Volt-VAr control characteristic is internally integrated into the optimization model as a set of constraints, making placement decisions more accurate. The objective of the optimization is to minimize the upgrading cost and the number of the smart inverters required while maintaining the voltage profile within the acceptable range. Case studies on an actual 12.47kV, 9km long Arizona utility feeder have been conducted using OpenDSS to validate the effectiveness of the proposed placement strategy in both static and dynamic simulations. Index Terms
△ Less
Submitted 1 July, 2022;
originally announced July 2022.
-
A Machine Learning-Based Method for Identifying Critical Distance Relays for Transient Stability Studies
Authors:
Ramin Vakili,
Mojdeh Khorsand
Abstract:
Modeling protective relays is crucial for performing accurate stability studies as they play a critical role in defining the dynamic responses of power systems during disturbances. Nevertheless, due to the current limitations of stability software and the challenges of kee** track of the changes in the settings information of thousands of protective relays, modeling all the protective relays in…
▽ More
Modeling protective relays is crucial for performing accurate stability studies as they play a critical role in defining the dynamic responses of power systems during disturbances. Nevertheless, due to the current limitations of stability software and the challenges of kee** track of the changes in the settings information of thousands of protective relays, modeling all the protective relays in bulk power systems is a challenging task. Distance relays are among the critical protection schemes, which are not properly modeled in current practices of stability studies. This paper proposes a machine learning-based method that uses the results of early-terminated stability studies to identify the critical distance relays required to be modeled in those studies. The algorithm used is the random forest (RF) classifier. GE positive sequence load flow analysis (PSLF) software is used to perform stability studies. The model is trained and tested on the Western Electricity Coordinating Council (WECC) system data representing the 2018 summer peak load under different operating conditions and topologies of the system. The results show the great performance of the method in identifying the critical distance relays. The results also show that only modeling the identified critical distance relays suffices to perform accurate stability studies.
△ Less
Submitted 9 April, 2022;
originally announced April 2022.
-
A Comprehensive Framework based on Dynamic and Steady State Analysis to Evaluate Power System Resiliency to Extreme Weather Conditions
Authors:
Giritharan Vijay Iswaran,
Ramin Vakili,
Mojdeh Khorsand
Abstract:
Power system robustness against high impact low probability events is becoming a major concern. To depict distinct phases of a system response during these disturbances, an irregular polygon model is derived from the conventional trapezoid model and the model is analytically investigated for transmission system performance, based on which resiliency metrics are developed for the same. Furthermore,…
▽ More
Power system robustness against high impact low probability events is becoming a major concern. To depict distinct phases of a system response during these disturbances, an irregular polygon model is derived from the conventional trapezoid model and the model is analytically investigated for transmission system performance, based on which resiliency metrics are developed for the same. Furthermore, the system resiliency to windstorm is evaluated on the IEEE reliability test system (RTS) by performing steady state and dynamic security assessment incorporating protection modelling and corrective action schemes using the software Power System Simulator for Engineering (PSS/E). Based on the results of steady state and dynamic analysis, modified resiliency metrics are quantified. Finally, this paper quantifies the interdependency of operational and infrastructure resiliency as they cannot be considered as discrete characteristics of the system.
△ Less
Submitted 7 July, 2022; v1 submitted 5 April, 2022;
originally announced April 2022.
-
Detailed Primary and Secondary Distribution System Model Enhancement Using AMI Data
Authors:
Karen Montano-Martinez,
Sushrut Thakar,
Shanshan Ma,
Zahra Soltani,
Vijay Vittal,
Mojdeh Khorsand,
Raja Ayyanar,
Cynthia Rojas
Abstract:
Reliable and accurate distribution system modeling, including the secondary network, is essential in examining distribution system performance with high penetration of distributed energy resources (DERs). This paper presents a highly automated, novel method to enhance the accuracy of utility distribution feeder models to capture their performance by matching simulation results with corresponding f…
▽ More
Reliable and accurate distribution system modeling, including the secondary network, is essential in examining distribution system performance with high penetration of distributed energy resources (DERs). This paper presents a highly automated, novel method to enhance the accuracy of utility distribution feeder models to capture their performance by matching simulation results with corresponding field measurements. The method is demonstrated using an actual feeder from an electrical utility with high penetration of DERs. The method proposed uses advanced metering infrastructure (AMI) voltage and derived active power measurements at the customer level, and data acquisition systems (DAS) measurements at the feeder-head, in conjunction with an AC optimal power flow (ACOPF) to estimate customer active and reactive power consumption over a time horizon, while accounting for unmetered loads. Additionally, the method proposed estimates both voltage magnitude and angle for each phase at the unbalanced distribution substation. Furthermore, the accuracy of the method developed is verified by comparing the time-series power flow results obtained from the enhancement algorithm with OpenDSS results. The proposed approach seamlessly manages the data available from the optimization procedure through the final model verification automatically.
△ Less
Submitted 28 May, 2021;
originally announced May 2021.
-
Day-ahead Operational Planning with Enhanced Flexible Ram** Product: Design and Analysis
Authors:
Mohammad Ghaljehei,
Mojdeh Khorsand
Abstract:
New resource mix, e.g., renewable resources, are imposing operational complexities to modern power systems by intensifying uncertainty and variability in the system net load. This issue has motivated independent system operators (ISOs), e.g., California ISO (CAISO), to add the flexible ram** product (FRP) to their day-ahead (DA) market models. Such structural changes in the DA market formulation…
▽ More
New resource mix, e.g., renewable resources, are imposing operational complexities to modern power systems by intensifying uncertainty and variability in the system net load. This issue has motivated independent system operators (ISOs), e.g., California ISO (CAISO), to add the flexible ram** product (FRP) to their day-ahead (DA) market models. Such structural changes in the DA market formulation require further analyses and detailed design to ensure adequate operational flexibility, market efficiency, and reliability. This paper conducts a comprehensive study to: (a) augment existing DA market models with enhanced FRP design in order to schedule ramp capabilities that are more adaptive with respect to the real-time (RT) condition, and (b) design corresponding market payment policies that accurately reflect the value of the added flexibility through enhanced FRP design. The proposed FRP design can be implemented in present-day system operations with minimal disruption to existing DA market models. Performance of the proposed DA market model, which includes the enhanced FRP design, is compared against the DA market model with existing FRP design through a validation methodology based on RT unit commitment model. This validation methodology mimics fifteen-minute market of CAISO. The proposed method is tested on an IEEE 118-bus test system.
△ Less
Submitted 8 December, 2020;
originally announced December 2020.
-
An Algorithmic Approach for Identifying Critical Distance Relays for Transient Stability Studies
Authors:
Ramin Vakili,
Mojdeh Khorsand,
Vijay Vittal,
Bill Robertson,
Philip Augustin
Abstract:
After major disturbances, power system behavior is governed by the dynamic characteristics of its assets and protection schemes. Therefore, modeling protection devices is essential for performing accurate stability studies. Modeling all the protection devices in a bulk power system is an intractable task due to the limitations of current stability software, and the difficulty of maintaining and up…
▽ More
After major disturbances, power system behavior is governed by the dynamic characteristics of its assets and protection schemes. Therefore, modeling protection devices is essential for performing accurate stability studies. Modeling all the protection devices in a bulk power system is an intractable task due to the limitations of current stability software, and the difficulty of maintaining and updating the data for thousands of protection devices. One of the critical protection schemes that is not adequately modeled in stability studies is distance relaying. Therefore, this paper proposes an algorithm that uses two methods to identify the critical distance relays to be modeled in stability studies: (i) apparent impedance monitoring, and (ii) the minimum voltage evaluation (MVE). The algorithm is implemented in Python 3.6 and uses the GE positive sequence load flow analysis (PSLF) software for performing stability studies. The performance of the algorithm is evaluated on the Western Electricity Coordinating Council (WECC) system data representing the 2018 summer-peak load. The results of the case studies representing various types of contingencies show that to have an accurate assessment of system behavior, modeling the critical distance relays identified by the algorithm suffices, and there is no need for modeling all the distance relays.
△ Less
Submitted 5 September, 2020;
originally announced September 2020.
-
Two-Stage Distributed Energy Resources Scheduling via Chance-Constrained AC Optimal Power Flow: A Second-Order Cone Programming Approach
Authors:
Mingyue He,
Zahra Soltani,
Mojdeh Khorsand
Abstract:
The penetration of distributed energy resources (DERs) is increasing dramatically. Due to the uncertainty of DERs, the operation of the distribution system is facing higher risks and challenges. To overcome such challenges, a two-stage chance-constrained convex AC optimal power flow (ACOPF) model is proposed in this paper, which can increase the economic efficiency of distribution system operation…
▽ More
The penetration of distributed energy resources (DERs) is increasing dramatically. Due to the uncertainty of DERs, the operation of the distribution system is facing higher risks and challenges. To overcome such challenges, a two-stage chance-constrained convex AC optimal power flow (ACOPF) model is proposed in this paper, which can increase the economic efficiency of distribution system operation and manage the intermittency of DERs. In the first stage, a convex second-order cone programming (SOCP)-based ACOPF model is proposed in which the detailed models and limitations of DER, namely, demand response (DR), energy storage units, and rooftop PV systems are modeled to obtain participation ratio of DERs. In the second stage, Monte Carlo simulation is utilized to model the uncertainties of DERs. A probability violation index is introduced to make a trade-off between scheduling more DERs and imposing a higher risk to the distribution system. In this stage, power flow analysis is conducted for each scenario to determine the probability violation index of system. Then, a modified SOCP-based ACOPF is proposed to satisfy the system probability violation criterion. Simulation results illustrate that the proposed two-stage chance-constrained model improves economic efficiency and reliability of real-time operation of the distribution system.
△ Less
Submitted 6 May, 2020;
originally announced May 2020.
-
Representation of Uncertainty in Electric Energy Market Models: Pricing Implication and Formulation
Authors:
Mohammad Ghaljehei,
Mojdeh Khorsand
Abstract:
Modern market management systems continue to evolve due to the intentions to improve system security and reliability. This evolvement has been leading to a transition of market auction models from a deterministic structure with approximations on the reliability criteria (e.g., acquirement of contingency reserve through proxy reserve policies) to explicit representation of contingencies (e.g., esti…
▽ More
Modern market management systems continue to evolve due to the intentions to improve system security and reliability. This evolvement has been leading to a transition of market auction models from a deterministic structure with approximations on the reliability criteria (e.g., acquirement of contingency reserve through proxy reserve policies) to explicit representation of contingencies (e.g., estimation of post-contingency states via participation factors and stochastic programming). This paper proposes a comprehensive framework to establish various procedures for evaluating: (i) transparency and incentive compatibility of different contingency modeling approaches, and (ii) efficiency of two possible stochastic market designs. First, the concept of securitized LMP is presented to solve the issue of how market participants should be compensated for providing N-1 reliability services. Then, pricing implications and settlements of three market models are compared: (i) a deterministic market model with proxy serve policies, (ii) state-of-the-art market models with estimated post-contingency states, and (iii) a two-stage stochastic market model. Second, this paper evaluates two stochastic market models while accounting for potential adjustments from day-ahead scheduling to real-time operation: (i) minimizing expected operating cost of all N-1 scenarios, and (ii) minimizing the base-case (or no contingency) cost. These analyses are conducted on IEEE 118-bus test system.
△ Less
Submitted 29 April, 2020;
originally announced April 2020.