-
High-resolution myelin-water fraction and quantitative relaxation map** using 3D ViSTa-MR fingerprinting
Authors:
Congyu Liao,
Xiaozhi Cao,
Siddharth Srinivasan Iyer,
Sophie Schauman,
Zihan Zhou,
Xiaoqian Yan,
Quan Chen,
Zhitao Li,
Nan Wang,
Ting Gong,
Zhe Wu,
Hongjian He,
Jianhui Zhong,
Yang Yang,
Adam Kerr,
Kalanit Grill-Spector,
Kawin Setsompop
Abstract:
Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous map** of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time.
Methods: We developed 3D ViSTa-MRF, which combined Visualization of Short Transverse relaxation time component (ViSTa) technique with MR Fingerprinting (MR…
▽ More
Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous map** of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time.
Methods: We developed 3D ViSTa-MRF, which combined Visualization of Short Transverse relaxation time component (ViSTa) technique with MR Fingerprinting (MRF), to achieve high-fidelity whole-brain MWF and T1/T2/PD map** on a clinical 3T scanner. To achieve fast acquisition and memory-efficient reconstruction, the ViSTa-MRF sequence leverages an optimized 3D tiny-golden-angle-shuffling spiral-projection acquisition and joint spatial-temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa-MRF approach, high-fidelity direct MWF map** was achieved without a need for multi-compartment fitting that could introduce bias and/or noise from additional assumptions or priors.
Results: The in-vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi-parametric map** with high SNR and good quality. The in-vivo results of 1mm- and 0.66mm-iso datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30x slower with lower SNR. Furthermore, we applied the proposed method to enable 5-minute whole-brain 1mm-iso assessment of MWF and T1/T2/PD map**s for infant brain development and for post-mortem brain samples.
Conclusions: In this work, we have developed a 3D ViSTa-MRF technique that enables the acquisition of whole-brain MWF, quantitative T1, T2, and PD maps at 1mm and 0.66mm isotropic resolution in 5 and 15 minutes, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
multiMap: A Gradient Spoiled Sequence for Simultaneously Measuring B1+, B0, T1/M0, T2, T2*, and Fat Fraction of a Slice
Authors:
Nicholas Dwork,
Adam B. Kerr,
Ethan M. I. Johnson,
Corey A. Baron,
Shreyas S. Vasanawala,
Peder E. Z. Larson,
Adam M. Bush,
John Pauly
Abstract:
We propose multiMap, a single scan that can generate several quantitative maps simultaneously. The sequence acquires multiple images in a time-efficient manner, which can be modeled for T_2, T2*, main- and transmit-field inhomogeneity, T_1:equilibrium magnetization, and water and fat content. The sequence is constructed so that cross-dependencies between parameters are isolated. Thus, each paramet…
▽ More
We propose multiMap, a single scan that can generate several quantitative maps simultaneously. The sequence acquires multiple images in a time-efficient manner, which can be modeled for T_2, T2*, main- and transmit-field inhomogeneity, T_1:equilibrium magnetization, and water and fat content. The sequence is constructed so that cross-dependencies between parameters are isolated. Thus, each parameter can be estimated independently. Estimates of all parameters are shown on bottle phantoms, the brain, and the knee. The results are compared to estimates from established techniques.
△ Less
Submitted 31 July, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Multi-coil Magnetic Resonance Imaging with Compressed Sensing Using Physically Motivated Regularization
Authors:
Nicholas Dwork,
Ethan M. I. Johnson,
Daniel O'Connor,
Jeremy W. Gordon,
Adam B. Kerr,
Corey A. Baron,
John M. Pauly,
Peder E. Z. Larson
Abstract:
With the advent of multi-coil imaging and compressed sensing, a number of model based reconstruction algorithms have been created. They incorporate a multitude of different regularization functions based on physics, observed phenomenology, and heuristics. Moreover, several iterative methods exist that attempt to simultaneously estimate the sensitivity maps and the image. In this manuscript, we pre…
▽ More
With the advent of multi-coil imaging and compressed sensing, a number of model based reconstruction algorithms have been created. They incorporate a multitude of different regularization functions based on physics, observed phenomenology, and heuristics. Moreover, several iterative methods exist that attempt to simultaneously estimate the sensitivity maps and the image. In this manuscript, we present a generalization of several existing iterative model based algorithms. We devise a calibrationless instance of this generalization that only incorporates regularization terms based on physics and the accepted compressed sensing phenomenology of sparsity in the wavelet domain. We compare the results of the new amalgamated optimization problem with existing methods on both simulated and real datasets. We show that the images reconstructed using the new method, entitled Multi-coil Compressed Sensing (MCCS), are of higher quality than existing methods in all cases studied.
△ Less
Submitted 2 February, 2023; v1 submitted 30 June, 2020;
originally announced July 2020.
-
Utilizing the Wavelet Transform's Structure in Compressed Sensing
Authors:
Nicholas Dwork,
Daniel O'Connor,
Corey A. Baron,
Ethan M. I. Johnson,
Adam B. Kerr,
John M. Pauly,
Peder E. Z. Larson
Abstract:
Compressed sensing has empowered quality image reconstruction with fewer data samples than previously though possible. These techniques rely on a sparsifying linear transformation. The Daubechies wavelet transform is a common sparsifying transformation used for this purpose. In this work, we take advantage of the structure of this wavelet transform and identify an affine transformation that increa…
▽ More
Compressed sensing has empowered quality image reconstruction with fewer data samples than previously though possible. These techniques rely on a sparsifying linear transformation. The Daubechies wavelet transform is a common sparsifying transformation used for this purpose. In this work, we take advantage of the structure of this wavelet transform and identify an affine transformation that increases the sparsity of the result. After inclusion of this affine transformation, we modify the resulting optimization problem to comply with the form of the Basis Pursuit Denoising problem. Finally, we show theoretically that this yields a lower bound on the error of the reconstruction and present results where solving this modified problem yields images of higher quality for the same sampling patterns.
△ Less
Submitted 16 June, 2021; v1 submitted 10 February, 2020;
originally announced February 2020.