-
A deep learning approach to using wearable seismocardiography (SCG) for diagnosing aortic valve stenosis and predicting aortic hemodynamics obtained by 4D flow MRI
Authors:
Mahmoud E. Khani,
Ethan M. I. Johnson,
Aparna Sodhi,
Joshua Robinson,
Cynthia K. Rigsby,
Bradly D. Allen,
Michael Markl
Abstract:
In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4D flow MRI using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated…
▽ More
In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4D flow MRI using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity Vmax in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the Vmax values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with TAV, BAV, MAV, and AS could be classified with ROC-AUC values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.
△ Less
Submitted 5 January, 2023;
originally announced January 2023.
-
MRI-MECH: Mechanics-informed MRI to estimate esophageal health
Authors:
Sourav Halder,
Ethan M. Johnson,
Jun Yamasaki,
Peter J. Kahrilas,
Michael Markl,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Dynamic magnetic resonance imaging (MRI) is a popular medical imaging technique to generate image sequences of the flow of a contrast material inside tissues and organs. However, its application to imaging bolus movement through the esophagus has only been demonstrated in few feasibility studies and is relatively unexplored. In this work, we present a computational framework called mechanics-infor…
▽ More
Dynamic magnetic resonance imaging (MRI) is a popular medical imaging technique to generate image sequences of the flow of a contrast material inside tissues and organs. However, its application to imaging bolus movement through the esophagus has only been demonstrated in few feasibility studies and is relatively unexplored. In this work, we present a computational framework called mechanics-informed MRI (MRI-MECH) that enhances that capability thereby increasing the applicability of dynamic MRI for diagnosing esophageal disorders. Pineapple juice was used as the swallowed contrast material for the dynamic MRI and the MRI image sequence was used as input to the MRI-MECH. The MRI-MECH modeled the esophagus as a flexible one-dimensional tube and the elastic tube walls followed a linear tube law. Flow through the esophagus was then governed by one-dimensional mass and momentum conservation equations. These equations were solved using a physics-informed neural network (PINN). The PINN minimized the difference between the measurements from the MRI and model predictions ensuring that the physics of the fluid flow problem was always followed. MRI-MECH calculated the fluid velocity and pressure during esophageal transit and estimated the mechanical health of the esophagus by calculating wall stiffness and active relaxation. Additionally, MRI-MECH predicted missing information about the lower esophageal sphincter during the emptying process, demonstrating its applicability to scenarios with missing data or poor image resolution. In addition to potentially improving clinical decisions based on quantitative estimates of the mechanical health of the esophagus, MRI-MECH can also be enhanced for application to other medical imaging modalities to enhance their functionality as well.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.
-
Least Squares Optimal Density Compensation for the Gridding Non-uniform Discrete Fourier Transform
Authors:
Nicholas Dwork,
Daniel O'Connor,
Ethan M. I. Johnson,
Corey A. Baron,
Jeremy W. Gordon,
John M. Pauly,
Peder E. Z. Larson
Abstract:
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measu…
▽ More
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measure 0) in the optimization. This manuscript presents the first density compensation algorithm for a general trajectory that takes into account the point spread function over a set of non-zero measure. We show that the images reconstructed with Gridding using the density compensation values of this method are of superior quality when compared to density compensation weights determined in other ways. Results are shown with a numerical phantom and with magnetic resonance images of the abdomen and the knee.
△ Less
Submitted 16 June, 2021; v1 submitted 11 June, 2021;
originally announced June 2021.
-
multiMap: A Gradient Spoiled Sequence for Simultaneously Measuring B1+, B0, T1/M0, T2, T2*, and Fat Fraction of a Slice
Authors:
Nicholas Dwork,
Adam B. Kerr,
Ethan M. I. Johnson,
Corey A. Baron,
Shreyas S. Vasanawala,
Peder E. Z. Larson,
Adam M. Bush,
John Pauly
Abstract:
We propose multiMap, a single scan that can generate several quantitative maps simultaneously. The sequence acquires multiple images in a time-efficient manner, which can be modeled for T_2, T2*, main- and transmit-field inhomogeneity, T_1:equilibrium magnetization, and water and fat content. The sequence is constructed so that cross-dependencies between parameters are isolated. Thus, each paramet…
▽ More
We propose multiMap, a single scan that can generate several quantitative maps simultaneously. The sequence acquires multiple images in a time-efficient manner, which can be modeled for T_2, T2*, main- and transmit-field inhomogeneity, T_1:equilibrium magnetization, and water and fat content. The sequence is constructed so that cross-dependencies between parameters are isolated. Thus, each parameter can be estimated independently. Estimates of all parameters are shown on bottle phantoms, the brain, and the knee. The results are compared to estimates from established techniques.
△ Less
Submitted 31 July, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Multi-coil Magnetic Resonance Imaging with Compressed Sensing Using Physically Motivated Regularization
Authors:
Nicholas Dwork,
Ethan M. I. Johnson,
Daniel O'Connor,
Jeremy W. Gordon,
Adam B. Kerr,
Corey A. Baron,
John M. Pauly,
Peder E. Z. Larson
Abstract:
With the advent of multi-coil imaging and compressed sensing, a number of model based reconstruction algorithms have been created. They incorporate a multitude of different regularization functions based on physics, observed phenomenology, and heuristics. Moreover, several iterative methods exist that attempt to simultaneously estimate the sensitivity maps and the image. In this manuscript, we pre…
▽ More
With the advent of multi-coil imaging and compressed sensing, a number of model based reconstruction algorithms have been created. They incorporate a multitude of different regularization functions based on physics, observed phenomenology, and heuristics. Moreover, several iterative methods exist that attempt to simultaneously estimate the sensitivity maps and the image. In this manuscript, we present a generalization of several existing iterative model based algorithms. We devise a calibrationless instance of this generalization that only incorporates regularization terms based on physics and the accepted compressed sensing phenomenology of sparsity in the wavelet domain. We compare the results of the new amalgamated optimization problem with existing methods on both simulated and real datasets. We show that the images reconstructed using the new method, entitled Multi-coil Compressed Sensing (MCCS), are of higher quality than existing methods in all cases studied.
△ Less
Submitted 2 February, 2023; v1 submitted 30 June, 2020;
originally announced July 2020.
-
Fast Variable Density Poisson-Disc Sample Generation with Directional Variation
Authors:
Nicholas Dwork,
Corey A. Baron,
Ethan M. I. Johnson,
Daniel O'Connor,
John M. Pauly,
Peder E. Z. Larson
Abstract:
We present a fast method for generating random samples according to a variable density Poisson-disc distribution. A minimum threshold distance is used to create a background grid array for kee** track of those points that might affect any new candidate point; this reduces the number of conflicts that must be checked before acceptance of a new point, thus reducing the number of computations requi…
▽ More
We present a fast method for generating random samples according to a variable density Poisson-disc distribution. A minimum threshold distance is used to create a background grid array for kee** track of those points that might affect any new candidate point; this reduces the number of conflicts that must be checked before acceptance of a new point, thus reducing the number of computations required. We demonstrate the algorithm's ability to generate variable density Poisson-disc sampling patterns according to a parameterized function, including patterns where the variations in density are a function of direction. We further show that these sampling patterns are appropriate for compressed sensing applications. Finally, we present a method to generate patterns with a specific acceleration rate.
△ Less
Submitted 16 June, 2021; v1 submitted 14 April, 2020;
originally announced April 2020.
-
Utilizing the Wavelet Transform's Structure in Compressed Sensing
Authors:
Nicholas Dwork,
Daniel O'Connor,
Corey A. Baron,
Ethan M. I. Johnson,
Adam B. Kerr,
John M. Pauly,
Peder E. Z. Larson
Abstract:
Compressed sensing has empowered quality image reconstruction with fewer data samples than previously though possible. These techniques rely on a sparsifying linear transformation. The Daubechies wavelet transform is a common sparsifying transformation used for this purpose. In this work, we take advantage of the structure of this wavelet transform and identify an affine transformation that increa…
▽ More
Compressed sensing has empowered quality image reconstruction with fewer data samples than previously though possible. These techniques rely on a sparsifying linear transformation. The Daubechies wavelet transform is a common sparsifying transformation used for this purpose. In this work, we take advantage of the structure of this wavelet transform and identify an affine transformation that increases the sparsity of the result. After inclusion of this affine transformation, we modify the resulting optimization problem to comply with the form of the Basis Pursuit Denoising problem. Finally, we show theoretically that this yields a lower bound on the error of the reconstruction and present results where solving this modified problem yields images of higher quality for the same sampling patterns.
△ Less
Submitted 16 June, 2021; v1 submitted 10 February, 2020;
originally announced February 2020.