-
LiverUSRecon: Automatic 3D Reconstruction and Volumetry of the Liver with a Few Partial Ultrasound Scans
Authors:
Kaushalya Sivayogaraj,
Sahan T. Guruge,
Udari Liyanage,
Jeevani Udupihille,
Saroj Jayasinghe,
Gerard Fernando,
Ranga Rodrigo,
M. Rukshani Liyanaarachchi
Abstract:
3D reconstruction of the liver for volumetry is important for qualitative analysis and disease diagnosis. Liver volumetry using ultrasound (US) scans, although advantageous due to less acquisition time and safety, is challenging due to the inherent noisiness in US scans, blurry boundaries, and partial liver visibility. We address these challenges by using the segmentation masks of a few incomplete…
▽ More
3D reconstruction of the liver for volumetry is important for qualitative analysis and disease diagnosis. Liver volumetry using ultrasound (US) scans, although advantageous due to less acquisition time and safety, is challenging due to the inherent noisiness in US scans, blurry boundaries, and partial liver visibility. We address these challenges by using the segmentation masks of a few incomplete sagittal-plane US scans of the liver in conjunction with a statistical shape model (SSM) built using a set of CT scans of the liver. We compute the shape parameters needed to warp this canonical SSM to fit the US scans through a parametric regression network. The resulting 3D liver reconstruction is accurate and leads to automatic liver volume calculation. We evaluate the accuracy of the estimated liver volumes with respect to CT segmentation volumes using RMSE. Our volume computation is statistically much closer to the volume estimated using CT scans than the volume computed using Childs' method by radiologists: p-value of 0.094 (>0.05) says that there is no significant difference between CT segmentation volumes and ours in contrast to Childs' method. We validate our method using investigations (ablation studies) on the US image resolution, the number of CT scans used for SSM, the number of principal components, and the number of input US scans. To the best of our knowledge, this is the first automatic liver volumetry system using a few incomplete US scans given a set of CT scans of livers for SSM.
△ Less
Submitted 27 June, 2024;
originally announced June 2024.
-
A Thickness Sensitive Vessel Extraction Framework for Retinal and Conjunctival Vascular Tortuosity Analysis
Authors:
Ashwin De Silva,
Malsha V. Perera,
Navodini Wijethilake,
Saroj Jayasinghe,
Nuwan D. Nanayakkara,
Anjula De Silva
Abstract:
Systemic diseases such as diabetes, hypertension, atherosclerosis are among the leading causes of annual human mortality rate. It is suggested that retinal and conjunctival vascular tortuosity is a potential biomarker for such systemic diseases. Most importantly, it is observed that the tortuosity depends on the thickness of these vessels. Therefore, selective calculation of tortuosity within spec…
▽ More
Systemic diseases such as diabetes, hypertension, atherosclerosis are among the leading causes of annual human mortality rate. It is suggested that retinal and conjunctival vascular tortuosity is a potential biomarker for such systemic diseases. Most importantly, it is observed that the tortuosity depends on the thickness of these vessels. Therefore, selective calculation of tortuosity within specific vessel thicknesses is required depending on the disease being analysed. In this paper, we propose a thickness sensitive vessel extraction framework that is primarily applicable for studies related to retinal and conjunctival vascular tortuosity. The framework uses a Convolutional Neural Network based on the IterNet architecture to obtain probability maps of the entire vasculature. They are then processed by a multi-scale vessel enhancement technique that exploits both fine and coarse structural vascular details of these probability maps in order to extract vessels of specified thicknesses. We evaluated the proposed framework on four datasets including DRIVE and SBVPI, and obtained Matthew's Correlation Coefficient values greater than 0.71 for all the datasets. In addition, the proposed framework was utilized to determine the association of diabetes with retinal and conjunctival vascular tortuosity. We observed that retinal vascular tortuosity (Eccentricity based Tortuosity Index) of the diabetic group was significantly higher (p < .05) than that of the non-diabetic group and that conjunctival vascular tortuosity (Total Curvature normalized by Arc Length) of diabetic group was significantly lower (p < .05) than that of the non-diabetic group. These observations were in agreement with the literature, strengthening the suitability of the proposed framework.
△ Less
Submitted 2 January, 2021;
originally announced January 2021.
-
Dynamic System Identification of Underwater Vehicles Using Multi-Output Gaussian Processes
Authors:
Wilmer Ariza Ramirez,
Jus Kocijan,
Zhi Leong,
Hung Nguyen,
Shantha Gamini Jayasinghe
Abstract:
Non-parametric system identification with Gaussian Processes for underwater vehicles is explored in this research with the purpose of modelling autonomous underwater vehicle (AUV) dynamics with low amount of data. Multi-output Gaussian processes and its aptitude to model the dynamic system of an underactuated AUV without losing the relationships between tied outputs is used. The simulation of a fi…
▽ More
Non-parametric system identification with Gaussian Processes for underwater vehicles is explored in this research with the purpose of modelling autonomous underwater vehicle (AUV) dynamics with low amount of data. Multi-output Gaussian processes and its aptitude to model the dynamic system of an underactuated AUV without losing the relationships between tied outputs is used. The simulation of a first-principles model of a Remus 100 AUV is employed to capture data for the training and validation of the multi-output Gaussian processes. The metric and required procedure to carry out multi-output Gaussian processes for AUV with 6 degrees of freedom (DoF) is also shown in this paper. Multi-output Gaussian processes are compared with the popular technique of recurrent neural network show that Multi-output Gaussian processes manage to surpass RNN for non-parametric dynamic system identification in underwater vehicles with highly coupled DoF with the added benefit of providing a measurement of confidence.
△ Less
Submitted 3 June, 2020;
originally announced June 2020.
-
Exploration of the Applicability of Probabilistic Inference for Learning Control in Underactuated Autonomous Underwater Vehicles
Authors:
Wilmer Ariza Ramirez,
Zhi Q. Leong,
Hung D. Nguyen,
S. G. Jayasinghe
Abstract:
Underwater vehicles are employed in the exploration of dynamic environments where tuning of a specific controller for each task would be time-consuming and unreliable as the controller depends on calculated mathematical coefficients in idealised conditions. For such a case, learning task from experience can be a useful alternative. This paper explores the capability of probabilistic inference lear…
▽ More
Underwater vehicles are employed in the exploration of dynamic environments where tuning of a specific controller for each task would be time-consuming and unreliable as the controller depends on calculated mathematical coefficients in idealised conditions. For such a case, learning task from experience can be a useful alternative. This paper explores the capability of probabilistic inference learning to control autonomous underwater vehicles that can be used for different tasks without re-programming the controller. Probabilistic inference learning uses a Gaussian process model of the real vehicle to learn the correct policy with a small number of real field experiments. The use of probabilistic reinforced learning looks for a simple implementation of controllers without the burden of coefficients calculation, controller tuning or system identification. A series of computational simulations were employed to test the applicability of model-based reinforced learning in underwater vehicles. Three simulation scenarios were evaluated: waypoint tracking, depth control and 3D path tracking control. The 3D path tracking is done by coupling together a line-of-sight law with probabilistic inference for learning control. As a comparison study LOS-PILCO algorithm can perform better than a robust LOS-PID. The results shows that probabilistic model based reinforced learning is a possible solution to motion control of underactuated AUVs as can generate capable policies with minimum quantity of episodes.
△ Less
Submitted 24 December, 2019;
originally announced December 2019.
-
A Customized System to Assess Foot Plantar Pressure: A Case Study on Calloused and Normal Feet
Authors:
A. M. A. I. Rathnayaka,
W. N. D. Perera,
H. P. Savindu,
K. C. M. Madarasingha,
S. P. Ranasinghe,
H. G. T. V. Thuduwage,
A. U. Kulathilaka,
P. Silva,
S. Jayasinghe,
K. T. D. Kahaduwa,
A. C. De Silva
Abstract:
Foot plantar pressure monitoring is an important tool for biomechanical assessment of posture, foot complications due to callus formation and wounds and for sports applications. The pronounced cost associated with commercial plantar pressure monitoring systems and inflexibility of custom analyzing data in such systems prompted the development of a versatile system with minimized cost. This study f…
▽ More
Foot plantar pressure monitoring is an important tool for biomechanical assessment of posture, foot complications due to callus formation and wounds and for sports applications. The pronounced cost associated with commercial plantar pressure monitoring systems and inflexibility of custom analyzing data in such systems prompted the development of a versatile system with minimized cost. This study focuses on the development of such a system with high speed data acquisition providing analysis tools for assessing plantar pressure variations of diabetic patients with calloused feet. The new system is capable of achieving a frame rate of 155 Hz which is ideal for pressure monitoring during both standing and walking. The system was verified using 10 normal subjects and 5 diabetic subjects with calluses on in their feet. Results indicate significantly high mechanical stresses on skin beneath callus and postural disorders during standing, in subjects with calluses.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
Development of a system to profile foot temperatures of the plantar and the periphery
Authors:
K. C. M. Madarasingha,
W. N. D. Perera,
A. M. A. I. Rathnayaka,
H. P. Savindu,
S. Jayasinghe,
K. T. D. Kahaduwa,
A. C. De Silva
Abstract:
Foot temperature profiling is of utmost importance is mitigating the adverse effects due to foot complications especially due to diabetes. Contactless temperature monitoring methods could be used effectively in large scale for patient screening. Near-infrared thermography has proven to be convenient and accurate for temperature profiling. The objective of this study is to develop a diagnostic devi…
▽ More
Foot temperature profiling is of utmost importance is mitigating the adverse effects due to foot complications especially due to diabetes. Contactless temperature monitoring methods could be used effectively in large scale for patient screening. Near-infrared thermography has proven to be convenient and accurate for temperature profiling. The objective of this study is to develop a diagnostic device using the said imaging technology to detect as well as progress monitoring of foot complications. The device we have developed is capable of scanning the foot plantar and the periphery and it is also accompanied by a semi-supervised thermal image analysis algorithm which is convenient to the clinician. Preliminary clinical testing conducted using 6 diabetic subjects out of which 2 had ulcers in either foot and 9 non-diabetic subjects 2 of which had wounds on the plantar. The system was able to detect the ulcerated areas and wounds with the algorithm developed specifically for thermal image analysis.
△ Less
Submitted 17 January, 2019; v1 submitted 10 January, 2019;
originally announced January 2019.