-
High-resolution myelin-water fraction and quantitative relaxation map** using 3D ViSTa-MR fingerprinting
Authors:
Congyu Liao,
Xiaozhi Cao,
Siddharth Srinivasan Iyer,
Sophie Schauman,
Zihan Zhou,
Xiaoqian Yan,
Quan Chen,
Zhitao Li,
Nan Wang,
Ting Gong,
Zhe Wu,
Hongjian He,
Jianhui Zhong,
Yang Yang,
Adam Kerr,
Kalanit Grill-Spector,
Kawin Setsompop
Abstract:
Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous map** of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time.
Methods: We developed 3D ViSTa-MRF, which combined Visualization of Short Transverse relaxation time component (ViSTa) technique with MR Fingerprinting (MR…
▽ More
Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous map** of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time.
Methods: We developed 3D ViSTa-MRF, which combined Visualization of Short Transverse relaxation time component (ViSTa) technique with MR Fingerprinting (MRF), to achieve high-fidelity whole-brain MWF and T1/T2/PD map** on a clinical 3T scanner. To achieve fast acquisition and memory-efficient reconstruction, the ViSTa-MRF sequence leverages an optimized 3D tiny-golden-angle-shuffling spiral-projection acquisition and joint spatial-temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa-MRF approach, high-fidelity direct MWF map** was achieved without a need for multi-compartment fitting that could introduce bias and/or noise from additional assumptions or priors.
Results: The in-vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi-parametric map** with high SNR and good quality. The in-vivo results of 1mm- and 0.66mm-iso datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30x slower with lower SNR. Furthermore, we applied the proposed method to enable 5-minute whole-brain 1mm-iso assessment of MWF and T1/T2/PD map**s for infant brain development and for post-mortem brain samples.
Conclusions: In this work, we have developed a 3D ViSTa-MRF technique that enables the acquisition of whole-brain MWF, quantitative T1, T2, and PD maps at 1mm and 0.66mm isotropic resolution in 5 and 15 minutes, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
Coil Sketching for computationally-efficient MR iterative reconstruction
Authors:
Julio A. Oscanoa,
Frank Ong,
Siddharth S. Iyer,
Zhitao Li,
Christopher M. Sandino,
Batu Ozturkler,
Daniel B. Ennis,
Mert Pilanci,
Shreyas S. Vasanawala
Abstract:
Purpose: Parallel imaging and compressed sensing reconstructions of large MRI datasets often have a prohibitive computational cost that bottlenecks clinical deployment, especially for 3D non-Cartesian acquisitions. One common approach is to reduce the number of coil channels actively used during reconstruction as in coil compression. While effective for Cartesian imaging, coil compression inherent…
▽ More
Purpose: Parallel imaging and compressed sensing reconstructions of large MRI datasets often have a prohibitive computational cost that bottlenecks clinical deployment, especially for 3D non-Cartesian acquisitions. One common approach is to reduce the number of coil channels actively used during reconstruction as in coil compression. While effective for Cartesian imaging, coil compression inherently loses signal energy, producing shading artifacts that compromise image quality for 3D non-Cartesian imaging. We propose coil sketching, a general and versatile method for computationally-efficient iterative MR image reconstruction.
Theory and Methods: We based our method on randomized sketching algorithms, a type of large-scale optimization algorithms well established in the fields of machine learning and big data analysis. We adapt the sketching theory to the MRI reconstruction problem via a structured sketching matrix that, similar to coil compression, considers high-energy virtual coils obtained from principal component analysis. But, unlike coil compression, it also considers random linear combinations of the remaining low-energy coils, effectively leveraging information from all coils.
Results: First, we performed ablation experiments to validate the sketching matrix design on both Cartesian and non-Cartesian datasets. The resulting design yielded both improved computational efficiency and preserved signal-to-noise ratio (SNR) as measured by the inverse g-factor. Then, we verified the efficacy of our approach on high-dimensional non-Cartesian 3D cones datasets, where coil sketching yielded up to three-fold faster reconstructions with equivalent image quality.
Conclusion: Coil sketching is a general and versatile reconstruction framework for computationally fast and memory-efficient reconstruction.
△ Less
Submitted 11 October, 2023; v1 submitted 10 May, 2023;
originally announced May 2023.
-
Optimized multi-axis spiral projection MR fingerprinting with subspace reconstruction for rapid whole-brain high-isotropic-resolution quantitative imaging
Authors:
Xiaozhi Cao,
Congyu Liao,
Siddharth Srinivasan Iyer,
Zhixing Wang,
Zihan Zhou,
Erpeng Dai,
Gilad Liberman,
Zi**g Dong,
Ting Gong,
Hongjian He,
Jianhui Zhong,
Berkin Bilgic,
Kawin Setsompop
Abstract:
Purpose: To improve image quality and accelerate the acquisition of 3D MRF. Methods: Building on the multi-axis spiral-projection MRF technique, a subspace reconstruction with locally low rank (LLR) constraint and a modified spiral-projection spatiotemporal encoding scheme termed tiny-golden-angle-shuffling (TGAS) were implemented for rapid whole-brain high-resolution quantitative map**. The LLR…
▽ More
Purpose: To improve image quality and accelerate the acquisition of 3D MRF. Methods: Building on the multi-axis spiral-projection MRF technique, a subspace reconstruction with locally low rank (LLR) constraint and a modified spiral-projection spatiotemporal encoding scheme termed tiny-golden-angle-shuffling (TGAS) were implemented for rapid whole-brain high-resolution quantitative map**. The LLR regularization parameter and the number of subspace bases were tuned using retrospective in-vivo data and simulated examinations, respectively. B0 inhomogeneity correction using multi-frequency interpolation was incorporated into the subspace reconstruction to further improve the image quality by mitigating blurring caused by off-resonance effect. Results: The proposed MRF acquisition and reconstruction framework can produce provide high quality 1-mm isotropic whole-brain quantitative maps in a total acquisition time of 1 minute 55 seconds, with higher-quality results than ones obtained from the previous approach in 6 minutes. The comparison of quantitative results indicates that neither the subspace reconstruction nor the TGAS trajectory induce bias for T1 and T2 map**. High quality whole-brain MRF data were also obtained at 0.66-mm isotropic resolution in 4 minutes using the proposed technique, where the increased resolution was shown to improve visualization of subtle brain structures. Conclusion: The proposed TGAS-SPI-MRF with optimized spiral-projection trajectory and subspace reconstruction can enable high-resolution quantitative map** with faster acquisition speed.
△ Less
Submitted 12 August, 2021;
originally announced August 2021.
-
Accuracy and Resiliency of Analog Compute-in-Memory Inference Engines
Authors:
Zhe Wan,
Tianyi Wang,
Yiming Zhou,
Subramanian S. Iyer,
Vwani P. Roychowdhury
Abstract:
Recently, analog compute-in-memory (CIM) architectures based on emerging analog non-volatile memory (NVM) technologies have been explored for deep neural networks (DNN) to improve energy efficiency. Such architectures, however, leverage charge conservation, an operation with infinite resolution, and thus are susceptible to errors. The computations in DNN realized by analog NVM thus have high uncer…
▽ More
Recently, analog compute-in-memory (CIM) architectures based on emerging analog non-volatile memory (NVM) technologies have been explored for deep neural networks (DNN) to improve energy efficiency. Such architectures, however, leverage charge conservation, an operation with infinite resolution, and thus are susceptible to errors. The computations in DNN realized by analog NVM thus have high uncertainty due to the device stochasticity. Several reports have demonstrated the use of analog NVM for CIM in a limited scale. It is unclear whether the uncertainties in computations will prohibit large-scale DNNs. To explore this critical issue of scalability, this paper first presents a simulation framework to evaluate the feasibility of large-scale DNNs based on CIM architecture and analog NVM. Simulation results show that DNNs trained for high-precision digital computing engines are not resilient against the uncertainty of the analog NVM devices. To avoid such catastrophic failures, this paper introduces the analog floating-point representation for the DNN, and the Hessian-Aware Stochastic Gradient Descent (HA-SGD) training algorithm to enhance the inference accuracy of trained DNNs. As a result of such enhancements, DNNs such as Wide ResNets for the CIFAR-100 image recognition problem are demonstrated to have significant performance improvements in accuracy without adding cost to the inference hardware.
△ Less
Submitted 5 August, 2020;
originally announced August 2020.
-
Nonlinear Dipole Inversion (NDI) enables Quantitative Susceptibility Map** (QSM) without parameter tuning
Authors:
Daniel Polak,
Itthi Chatnuntawech,
Jaeyeon Yoon,
Siddharth Srinivasan Iyer,
Jongho Lee,
Peter Bachert,
Elfar Adalsteinsson,
Kawin Setsompop,
Berkin Bilgic
Abstract:
We propose Nonlinear Dipole Inversion (NDI) for high-quality Quantitative Susceptibility Map** (QSM) without regularization tuning, while matching the image quality of state-of-the-art reconstruction techniques. In addition to avoiding over-smoothing that these techniques often suffer from, we also obviate the need for parameter selection. NDI is flexible enough to allow for reconstruction from…
▽ More
We propose Nonlinear Dipole Inversion (NDI) for high-quality Quantitative Susceptibility Map** (QSM) without regularization tuning, while matching the image quality of state-of-the-art reconstruction techniques. In addition to avoiding over-smoothing that these techniques often suffer from, we also obviate the need for parameter selection. NDI is flexible enough to allow for reconstruction from an arbitrary number of head orientations, and outperforms COSMOS even when using as few as 1-direction data. This is made possible by a nonlinear forward-model that uses the magnitude as an effective prior, for which we derived a simple gradient descent update rule. We synergistically combine this physics-model with a Variational Network (VN) to leverage the power of deep learning in the VaNDI algorithm. This technique adopts the simple gradient descent rule from NDI and learns the network parameters during training, hence requires no additional parameter tuning. Further, we evaluate NDI at 7T using highly accelerated Wave-CAIPI acquisitions at 0.5 mm isotropic resolution and demonstrate high-quality QSM from as few as 2-direction data.
△ Less
Submitted 30 September, 2019;
originally announced September 2019.
-
Efficient T2 map** with Blip-up/down EPI and gSlider-SMS (T2-BUDA-gSlider)
Authors:
Xiaozhi Cao,
Congyu Liao,
Zi**g Zhang,
Siddharth Srinivasan Iyer,
Kang Wang,
Hongjian He,
Huafeng Liu,
Kawin Setsompop,
Jianhui Zhong,
Berkin Bilgic
Abstract:
Purpose: To rapidly obtain high isotropic-resolution T2 maps with whole-brain coverage and high geometric fidelity.
Methods: A T2 blip-up/down echo planar imaging (EPI) acquisition with generalized Slice-dithered enhanced resolution (T2-BUDA-gSlider) is proposed. A radiofrequency (RF)-encoded multi-slab spin-echo EPI acquisition with multiple echo times (TEs) was developed to obtain high SNR eff…
▽ More
Purpose: To rapidly obtain high isotropic-resolution T2 maps with whole-brain coverage and high geometric fidelity.
Methods: A T2 blip-up/down echo planar imaging (EPI) acquisition with generalized Slice-dithered enhanced resolution (T2-BUDA-gSlider) is proposed. A radiofrequency (RF)-encoded multi-slab spin-echo EPI acquisition with multiple echo times (TEs) was developed to obtain high SNR efficiency with reduced repetition time (TR). This was combined with an interleaved 2-shot EPI acquisition using blip-up/down phase encoding. An estimated field map was incorporated into the joint multi-shot EPI reconstruction with a structured low rank constraint to achieve distortion-free and robust reconstruction for each slab without navigation. A Bloch simulated subspace model was integrated into gSlider reconstruction and utilized for T2 quantification.
Results: In vivo results demonstrated that the T2 values estimated by the proposed method were consistent with gold standard spin-echo acquisition. Compared to the reference 3D fast spin echo (FSE) images, distortion caused by off-resonance and eddy current effects were effectively mitigated.
Conclusion: BUDA-gSlider SE-EPI acquisition and gSlider-subspace joint reconstruction enabled distortion-free whole-brain T2 map** in 2 min at ~1 mm3 isotropic resolution, which could bring significant benefits to related clinical and neuroscience applications.
△ Less
Submitted 20 September, 2020; v1 submitted 27 September, 2019;
originally announced September 2019.