Real-time myocardial landmark tracking for MRI-guided cardiac radio-ablation using Gaussian Processes
Authors:
Niek R. F. Huttinga,
Osman Akdag,
Martin F. Fast,
Joost Verhoeff,
Firdaus A. A. Mohamed Hoesein,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi,
Stefano Mandija
Abstract:
The high speed of cardiorespiratory motion introduces a unique challenge for cardiac stereotactic radio-ablation (STAR) treatments with the MR-linac. Such treatments require tracking myocardial landmarks with a maximum latency of 100 ms, which includes the acquisition of the required data. The aim of this study is to present a new method that allows to track myocardial landmarks from few readouts…
▽ More
The high speed of cardiorespiratory motion introduces a unique challenge for cardiac stereotactic radio-ablation (STAR) treatments with the MR-linac. Such treatments require tracking myocardial landmarks with a maximum latency of 100 ms, which includes the acquisition of the required data. The aim of this study is to present a new method that allows to track myocardial landmarks from few readouts of MRI data, thereby achieving a latency sufficient for STAR treatments. We present a tracking framework that requires only few readouts of k-space data as input, which can be acquired at least an order of magnitude faster than MR-images. Combined with the real-time tracking speed of a probabilistic machine learning framework called Gaussian Processes, this allows to track myocardial landmarks with a sufficiently low latency for cardiac STAR guidance, including both the acquisition of required data, and the tracking inference. The framework is demonstrated in 2D on a motion phantom, and in vivo on volunteers and a ventricular tachycardia (arrhythmia) patient. Moreover, the feasibility of an extension to 3D was demonstrated by in silico 3D experiments with a digital motion phantom. The framework was compared with template matching - a reference, image-based, method - and linear regression methods. Results indicate an order of magnitude lower total latency (<10 ms) for the proposed framework in comparison with alternative methods. The root-mean-square-distances and mean end-point-distance with the reference tracking method was less than 0.8 mm for all experiments, showing excellent (sub-voxel) agreement. The high accuracy in combination with a total latency of less than 10 ms - including data acquisition and processing - make the proposed method a suitable candidate for tracking during STAR treatments.
△ Less
Submitted 19 June, 2023;
originally announced June 2023.
-
Towards retrospective motion correction and reconstruction for clinical 3D brain MRI protocols with a reference contrast
Authors:
Gabrio Rizzuti,
Tim Schakel,
Niek R. F. Huttinga,
Jan Willem Dankbaar,
Tristan van Leeuwen,
Alessandro Sbrizzi
Abstract:
Motion artifacts often spoil the radiological interpretation of MR images, and in the most severe cases the scan needs be repeated, with additional costs for the provider. We discuss the application of a novel 3D retrospective rigid motion correction and reconstruction scheme for MRI, which leverages multiple scans contained in a MR session. Typically, in a multi-contrast MR session, motion does n…
▽ More
Motion artifacts often spoil the radiological interpretation of MR images, and in the most severe cases the scan needs be repeated, with additional costs for the provider. We discuss the application of a novel 3D retrospective rigid motion correction and reconstruction scheme for MRI, which leverages multiple scans contained in a MR session. Typically, in a multi-contrast MR session, motion does not equally affect all the scans, and some motion-free scans are generally available, so that we can exploit their anatomic similarity. The uncorrupted scan is used as a reference in a generalized rigid-motion registration problem to remove the motion artifacts affecting the corrupted scans. We discuss the potential of the proposed algorithm with a prospective in-vivo study and clinical 3D brain protocols. This framework can be easily incorporated into the existing clinical practice with no disruption to the conventional workflow.
△ Less
Submitted 3 January, 2023;
originally announced January 2023.
-
Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUS
Authors:
Niek R. F. Huttinga,
Tom Bruijnen,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy with MRI, and adjusting the radiotherapy plan accordingly. Optimal MR-guidance for respiratory motion during radiotherapy requires MR-based 3D motion estimation wi…
▽ More
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy with MRI, and adjusting the radiotherapy plan accordingly. Optimal MR-guidance for respiratory motion during radiotherapy requires MR-based 3D motion estimation with a latency of 200-500 ms. Currently this is still challenging since typical methods rely on MR-images, and are therefore limited by the 3D MR-imaging latency. In this work, we present a method to perform non-rigid 3D respiratory motion estimation with 170 ms latency, including both acquisition and reconstruction. The proposed method called real-time low-rank MR-MOTUS reconstructs motion-fields directly from k-space data, and leverages an explicit low-rank decomposition of motion-fields to split the large scale 3D+t motion-field reconstruction problem posed in our previous work into two parts: (I) a medium-scale offline preparation phase and (II) a small-scale online inference phase which exploits the results of the offline phase for real-time computations. The method was validated on free-breathing data of five volunteers, acquired with a 1.5T Elekta Unity MR-Linac. Results show that the reconstructed 3D motion-field are anatomically plausible, highly correlated with a self-navigation motion surrogate (R = 0.975 +/- 0.0110), and can be reconstructed with a total latency of 170 ms that is sufficient for real-time MR-guided abdominal radiotherapy.
△ Less
Submitted 14 September, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Non-rigid 3D motion estimation at high temporal resolution from prospectively undersampled k-space data using low-rank MR-MOTUS
Authors:
Niek R. F. Huttinga,
Tom Bruijnen,
Cornelis A. T. van den Berg,
Alessandro Sbrizzi
Abstract:
With the recent introduction of the MR-LINAC, an MR-scanner combined with a radiotherapy LINAC, MR-based motion estimation has become of increasing interest to (retrospectively) characterize tumor and organs-at-risk motion during radiotherapy. To this extent, we introduce low-rank MR-MOTUS, a framework to retrospectively reconstruct time-resolved non-rigid 3D+t motion-fields from a single low-reso…
▽ More
With the recent introduction of the MR-LINAC, an MR-scanner combined with a radiotherapy LINAC, MR-based motion estimation has become of increasing interest to (retrospectively) characterize tumor and organs-at-risk motion during radiotherapy. To this extent, we introduce low-rank MR-MOTUS, a framework to retrospectively reconstruct time-resolved non-rigid 3D+t motion-fields from a single low-resolution reference image and prospectively undersampled k-space data acquired during motion. Low-rank MR-MOTUS exploits spatio-temporal correlations in internal body motion with a low-rank motion model, and inverts a signal model that relates motion-fields directly to a reference image and k-space data. The low-rank model reduces the degrees-of-freedom, memory consumption and reconstruction times by assuming a factorization of space-time motion-fields in spatial and temporal components. Low-rank MR-MOTUS was employed to estimate motion in 2D/3D abdominothoracic scans and 3D head scans. Data were acquired using golden-ratio radial readouts. Reconstructed 2D and 3D respiratory motion-fields were respectively validated against time-resolved and respiratory-resolved image reconstructions, and the head motion against static image reconstructions from fully-sampled data acquired right before and right after the motion. Results show that 2D+t respiratory motion can be estimated retrospectively at 40.8 motion-fields-per-second, 3D+t respiratory motion at 7.6 motion-fields-per-second and 3D+t head-neck motion at 9.3 motion-fields-per-second. The validations show good consistency with image reconstructions. The proposed framework can estimate time-resolved non-rigid 3D motion-fields, which allows to characterize drifts and intra and inter-cycle patterns in breathing motion during radiotherapy, and could form the basis for real-time MR-guided radiotherapy.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Opening a new window on MR-based Electrical Properties Tomography with deep learning
Authors:
Stefano Mandija,
Ettore F. Meliadò,
Niek R. F. Huttinga,
Peter R. Luijten,
Cornelis A. T. van den Berg
Abstract:
Electrical properties (EPs) of tissues, conductivity and permittivity, are modulated by the ionic and water content, which change in presence of pathologies. Information on tissues EPs can be used e.g. as an endogenous biomarker in oncology. MR-Electrical Properties Tomography (MR-EPT) aims to reconstruct tissue EPs by solving an electromagnetic inverse problem relating MR measurements of the tran…
▽ More
Electrical properties (EPs) of tissues, conductivity and permittivity, are modulated by the ionic and water content, which change in presence of pathologies. Information on tissues EPs can be used e.g. as an endogenous biomarker in oncology. MR-Electrical Properties Tomography (MR-EPT) aims to reconstruct tissue EPs by solving an electromagnetic inverse problem relating MR measurements of the transmit radiofrequency RF field to the EPs. However, MR-EPT reconstructions highly suffer from noise in the RF field maps, which limits the clinical applicability. Instead of employing electromagnetic models posing strict requirements on the measured quantities, we propose a data driven approach where the inverse transformation is learned by means of a neural network. Supervised training of a conditional generative adversarial neural network was performed using simulated realistic RF field maps and realistic human head dielectric models. Deep learning EPT (DL-EPT) reconstructions are presented for in-silica MR data and MR measurements at 3 Tesla on phantoms and human brains. DL-EPT shows high quality EP maps, demonstrating good accuracy and greatly improved precision compared to conventional MR-EPT. Moreover, DL-EPT allows permittivity reconstructions at 3 Tesla, which is not possible with state-of-art MR-EPT techniques. The supervised learning-based approach leverages the strength of tailored electromagnetic simulations, allowing inclusion of a priori information (e.g. coil setup) and circumvention of inaccessible MR electromagnetic quantities. Since DL-EPT is highly noise-robust, the requirements for MRI data acquisitions can be relaxed, allowing faster acquisitions and higher resolutions. We believe that DL-EPT greatly improves the quality and applicability of EPT opening a new window for an endogenous biomarker in MRI diagnostics that reflects differences in ionic tissue content.
△ Less
Submitted 19 August, 2019; v1 submitted 30 March, 2018;
originally announced April 2018.