-
Quantitative perfusion maps using a novelty spatiotemporal convolutional neural network
Authors:
Anbo Cao,
Pin-Yu Le,
Zhonghui Qie,
Haseeb Hassan,
Yingwei Guo,
Asim Zaman,
Jiaxi Lu,
Xueqiang Zeng,
Huihui Yang,
Xiaoqiang Miao,
Taiyu Han,
Guangtao Huang,
Yan Kang,
Yu Luo,
Jia Guo
Abstract:
Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) is widely used to evaluate acute ischemic stroke to distinguish salvageable tissue and infarct core. For this purpose, traditional methods employ deconvolution techniques, like singular value decomposition, which are known to be vulnerable to noise, potentially distorting the derived perfusion parameters. However, deep learning t…
▽ More
Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) is widely used to evaluate acute ischemic stroke to distinguish salvageable tissue and infarct core. For this purpose, traditional methods employ deconvolution techniques, like singular value decomposition, which are known to be vulnerable to noise, potentially distorting the derived perfusion parameters. However, deep learning technology could leverage it, which can accurately estimate clinical perfusion parameters compared to traditional clinical approaches. Therefore, this study presents a perfusion parameters estimation network that considers spatial and temporal information, the Spatiotemporal Network (ST-Net), for the first time. The proposed network comprises a designed physical loss function to enhance model performance further. The results indicate that the network can accurately estimate perfusion parameters, including cerebral blood volume (CBV), cerebral blood flow (CBF), and time to maximum of the residual function (Tmax). The structural similarity index (SSIM) mean values for CBV, CBF, and Tmax parameters were 0.952, 0.943, and 0.863, respectively. The DICE score for the hypo-perfused region reached 0.859, demonstrating high consistency. The proposed model also maintains time efficiency, closely approaching the performance of commercial gold-standard software.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
3D Cross-Pseudo Supervision (3D-CPS): A semi-supervised nnU-Net architecture for abdominal organ segmentation
Authors:
Yongzhi Huang,
Hanwen Zhang,
Yan Yan,
Haseeb Hassan
Abstract:
Large curated datasets are necessary, but annotating medical images is a time-consuming, laborious, and expensive process. Therefore, recent supervised methods are focusing on utilizing a large amount of unlabeled data. However, to do so, is a challenging task. To address this problem, we propose a new 3D Cross-Pseudo Supervision (3D-CPS) method, a semi-supervised network architecture based on nnU…
▽ More
Large curated datasets are necessary, but annotating medical images is a time-consuming, laborious, and expensive process. Therefore, recent supervised methods are focusing on utilizing a large amount of unlabeled data. However, to do so, is a challenging task. To address this problem, we propose a new 3D Cross-Pseudo Supervision (3D-CPS) method, a semi-supervised network architecture based on nnU-Net with the Cross-Pseudo Supervision method. We design a new nnU-Net based preprocessing. In addition, we set the semi-supervised loss weights to expand linearity with each epoch to prevent the model from low-quality pseudo-labels in the early training process. Our proposed method achieves an average dice similarity coefficient (DSC) of 0.881 and an average normalized surface distance (NSD) of 0.913 on the MICCAI FLARE2022 validation set (20 cases).
△ Less
Submitted 1 November, 2022; v1 submitted 19 September, 2022;
originally announced September 2022.
-
Multi-Material Topology Optimization with Continuous Magnetization Direction for Permanent Magnet Synchronous Reluctance Motors
Authors:
Thomas Gauthey,
Peter Gangl,
Maya Hage Hassan
Abstract:
Permanent magnet-assisted synchronous reluctance motors (PMSynRM) have a significantly higher average torque than synchronous reluctance motors. Thus, determining an optimal design results in a multi-material topology optimization problem, where one seeks to distribute ferromagnetic material, air and permanent magnets within the rotor in an optimal manner. This study proposed a novel density-based…
▽ More
Permanent magnet-assisted synchronous reluctance motors (PMSynRM) have a significantly higher average torque than synchronous reluctance motors. Thus, determining an optimal design results in a multi-material topology optimization problem, where one seeks to distribute ferromagnetic material, air and permanent magnets within the rotor in an optimal manner. This study proposed a novel density-based distribution scheme, which allows for continuous magnetization direction instead of a finite set of angles. Thus, an interpolation scheme is established between properties pertaining to magnets and non-linear materials. This allows for new designs to emerge without introducing complex geometric parameterization or relying on the user's biases and intuitions. Toward reducing computation time, Nitsche-type mortaring is applied, allowing for free rotation of the rotor mesh relative to the stator mesh. The average torque is approximated using only four-point static positions. This study investigates several interpolation schemes and presents a new one inspired by the topological derivative. We propose to filter the final design for the magnetization angle using K-mean clustering accounting for technical feasibility constraints of magnets. Finally, the design of the electrical motor is proposed to maximize torque value.
△ Less
Submitted 10 July, 2021;
originally announced July 2021.
-
Teleoperated Robotic Arm Movement Using EMG Signal With Wearable MYO Armband
Authors:
Hussein F. Hassan,
Sadiq J. Abou-Loukh,
Ibraheem Kasim Ibraheem
Abstract:
The main purpose of this research is to move the robotic arm (5DoF) in real-time, based on the surface Electromyography (sEMG) signals, as obtained from the wireless Myo gesture armband to distinguish seven hand movements. The sEMG signals are biomedical signals that estimate and record the electrical signals produced in muscles through their contraction and relaxation, representing neuromuscular…
▽ More
The main purpose of this research is to move the robotic arm (5DoF) in real-time, based on the surface Electromyography (sEMG) signals, as obtained from the wireless Myo gesture armband to distinguish seven hand movements. The sEMG signals are biomedical signals that estimate and record the electrical signals produced in muscles through their contraction and relaxation, representing neuromuscular activities. Therefore, controlling the robotic arm via the muscles of the human arm using sEMG signals is considered to be one of the most significant methods. The wireless Myo gesture armband is used to record sEMG signals from the forearm. In order to analyze these signals, the pattern recognition system is employed, which consists of three main parts: segmentation, feature extraction, and classification. Overlap technique is chosen for segmenting part of the signal. Six time domain features (MAV, WL, RMS, AR, ZC, and SSC) are extracted from each segment. The classifiers (SVM, LDA, and KNN) are employed to enable comparison between them in order to obtain optimum accuracy of the system. The results show that the SVM achieves higher system accuracy at 96.57 %, compared to LDA reaching 96.01 %, and 92.67 % accuracy achieved by KNN.
△ Less
Submitted 3 October, 2018;
originally announced October 2018.