3D Ultrafast Shear Wave Absolute Vibro-Elastography using a Matrix Array Transducer
Authors:
Hoda S. Hashemi,
Shahed K. Mohammed,
Qi Zeng,
Reza Zahiri Azar,
Robert N. Rohling,
Septimiu E. Salcudean
Abstract:
3D ultrasound imaging provides more spatial information compared to conventional 2D frames by considering the volumes of data. One of the main bottlenecks of 3D imaging is the long data acquisition time which reduces practicality and can introduce artifacts from unwanted patient or sonographer motion. This paper introduces the first shear wave absolute vibro-elastography (S-WAVE) method with real-…
▽ More
3D ultrasound imaging provides more spatial information compared to conventional 2D frames by considering the volumes of data. One of the main bottlenecks of 3D imaging is the long data acquisition time which reduces practicality and can introduce artifacts from unwanted patient or sonographer motion. This paper introduces the first shear wave absolute vibro-elastography (S-WAVE) method with real-time volumetric acquisition using a matrix array transducer. In SWAVE, an external vibration source generates mechanical vibrations inside the tissue. The tissue motion is then estimated and used in solving a wave equation inverse problem to provide the tissue elasticity. A matrix array transducer is used with a Verasonics ultrasound machine and frame rate of 2000 volumes/s to acquire 100 radio frequency (RF) volumes in 0.05 s. Using plane wave (PW) and compounded diverging wave (CDW) imaging methods, we estimate axial, lateral and elevational displacements over 3D volumes. The curl of the displacements is used with local frequency estimation to estimate elasticity in the acquired volumes. Ultrafast acquisition extends substantially the possible S-WAVE excitation frequency range, now up to 800 Hz, enabling new tissue modeling and characterization. The method was validated on three homogeneous liver fibrosis phantoms and on four different inclusions within a heterogeneous phantom. The homogeneous phantom results show less than 8% (PW) and 5% (CDW) difference between the manufacturer values and the corresponding estimated values over a frequency range of 80 Hz to 800 Hz. The estimated elasticity values for the heterogeneous phantom at 400 Hz excitation frequency show average errors of 9% (PW) and 6% (CDW) compared to the provided average values by MRE. Furthermore, both imaging methods were able to detect the inclusions within the elasticity volumes.
△ Less
Submitted 22 May, 2023;
originally announced September 2023.
-
Ultrafast Ultrasound Imaging for 3D Shear Wave Absolute Vibro-Elastography
Authors:
Hoda S. Hashemi,
Reza Zahiri Azar,
Septimiu E. Salcudean,
Robert N. Rohling
Abstract:
Shear wave absolute vibro-elastography (S-WAVE) is an imaging technique that generates steady-state shear waves inside the tissue using multi-frequency excitation from an external vibration source. In this work, plane wave imaging is introduced to reduce total acquisition time while retaining the benefit of 3D formulation. Plane wave imaging with a frame rate of 3000 frames/s is followed by 3D abs…
▽ More
Shear wave absolute vibro-elastography (S-WAVE) is an imaging technique that generates steady-state shear waves inside the tissue using multi-frequency excitation from an external vibration source. In this work, plane wave imaging is introduced to reduce total acquisition time while retaining the benefit of 3D formulation. Plane wave imaging with a frame rate of 3000 frames/s is followed by 3D absolute elasticity estimation. We design two imaging sequences of ultrafast S-WAVE for two sets of excitation frequencies using a Verasonics system and a motorized swept ultrasound transducer to synchronize ultrasound acquisition with the external mechanical excitation. The overall data collection time is improved by 83-88% compared to the original 3D S-WAVE because of the per-channel acquisition offered by the Verasonics system. Tests are performed on liver fibrosis tissue-mimicking phantoms and on ex vivo bovine liver. The curl operator was previously used in magnetic resonance elastography (MRE) to cancel out the effect of the compressional waves. In this work, we apply the curl operator to the full 3D displacement field followed by 3D elasticity reconstruction. The results of phantom experiment show more accurate elasticity estimation as well as 18% less standard deviation (STD) compared to reconstruction using the curl of a 2D displacement field and 45% less STD than without the curl. We also compare our experimental results with a previous method based on acoustic radiation force impulse (ARFI) and achieve closer results to phantom manufacturer provided values with ultrafast S-WAVE. Furthermore, the dependency of the bovine liver elasticity on the frequency of excitation was also shown with our system.
△ Less
Submitted 25 July, 2023; v1 submitted 25 March, 2022;
originally announced March 2022.