-
An Efficient Algorithm for Spatial-Spectral Partial Volume Compartment Map** with Applications to Multicomponent Diffusion and Relaxation MRI
Authors:
Yunsong Liu,
Debdut Mandal,
Congyu Liao,
Kawin Setsompop,
Justin P. Haldar
Abstract:
Previous work has shown that high-quality partial volume tissue compartment maps can be obtained by applying spatially-regularized spectroscopic image estimation techniques to high-dimensional multicontrast MRI data (e.g., diffusion-relaxation data). However, this generally requires substantial computational complexity. In this work, we propose a more efficient algorithm to estimate spectroscopic…
▽ More
Previous work has shown that high-quality partial volume tissue compartment maps can be obtained by applying spatially-regularized spectroscopic image estimation techniques to high-dimensional multicontrast MRI data (e.g., diffusion-relaxation data). However, this generally requires substantial computational complexity. In this work, we propose a more efficient algorithm to estimate spectroscopic images using spatial regularization. Our algorithm is based on the linearized alternating directions method of multipliers (LADMM), and relies on the introduction of novel quadratic penalty terms to substantially simplify the subproblems that appear within each iteration. We evaluate this algorithm in a variety of different scenarios (diffusion-relaxation, relaxation-relaxation, relaxometry, and magnetic resonance fingerprinting), where we consistently observe substantial ($\sim$3$\times$-50$\times$) speed improvements. We expect that this new algorithm will reduce barriers to using spatial regularization and multiparametric contrast-encoded MRI data acquisition methods for partial volume compartment map**.
△ Less
Submitted 5 June, 2024; v1 submitted 23 January, 2024;
originally announced January 2024.
-
On Optimality in ROVir
Authors:
Justin P. Haldar
Abstract:
We recently published an approach named ROVir (Region-Optimized Virtual coils) that uses the beamforming capabilities of a multichannel magnetic resonance imaging (MRI) receiver array to achieve coil compression (reducing an original set of receiver channels into a much smaller number of virtual channels for the purposes of dimensionality reduction), while simultaneously preserving the MRI signal…
▽ More
We recently published an approach named ROVir (Region-Optimized Virtual coils) that uses the beamforming capabilities of a multichannel magnetic resonance imaging (MRI) receiver array to achieve coil compression (reducing an original set of receiver channels into a much smaller number of virtual channels for the purposes of dimensionality reduction), while simultaneously preserving the MRI signal from desired spatial regions and suppressing the MRI signal arising from unwanted spatial regions. The original ROVir procedure is computationally-simple to implement (involving just a single small generalized eigendecomposition), and its signal-suppression capabilities have proven useful in an increasingly wide range of MRI applications. Our original paper made claims about the theoretical optimality of this generalized eigendecomposition procedure, but did not present the details. The purpose of this write-up is to elaborate on these mathematical details, and to introduce a new greedy iterative ROVir algorithm that enjoys certain advantages over the original ROVir calculation approach. This discussion is largely academic, with implications that we suspect will be minor for practical applications -- we have only observed small improvements to ROVir performance in the cases we have tried, and it would have been safe in these cases to still use the simpler original calculation procedure with negligible practical impact on the final imaging results.
△ Less
Submitted 20 July, 2023;
originally announced July 2023.
-
Extended Version of "New Theory and Faster Computations for Subspace-Based Sensitivity Map Estimation in Multichannel MRI''
Authors:
Rodrigo A. Lobos,
Chin-Cheng Chan,
Justin P. Haldar
Abstract:
This is an unabridged version of a journal manuscript that has been submitted for publication [1]. (Due to length restrictions, we were forced to remove substantial amounts of content from the version that was submitted to the journal, including more detailed theoretical explanations, additional figures, and a more comprehensive bibliography. This content remains intact in this version of the docu…
▽ More
This is an unabridged version of a journal manuscript that has been submitted for publication [1]. (Due to length restrictions, we were forced to remove substantial amounts of content from the version that was submitted to the journal, including more detailed theoretical explanations, additional figures, and a more comprehensive bibliography. This content remains intact in this version of the document).
Sensitivity map estimation is important in many multichannel MRI applications. Subspace-based sensitivity map estimation methods like ESPIRiT are popular and perform well, though can be computationally expensive and their theoretical principles can be nontrivial to understand. In the first part of this work, we present a novel theoretical derivation of subspace-based sensitivity map estimation based on a linear-predictability/structured low-rank modeling perspective. This results in an estimation approach that is equivalent to ESPIRiT, but with distinct theory that may be more intuitive for some readers. In the second part of this work, we propose and evaluate a set of computational acceleration approaches (collectively known as PISCO) that can enable substantial improvements in computation time (up to ~100x in the examples we show) and memory for subspace-based sensitivity map estimation.
△ Less
Submitted 26 February, 2023;
originally announced February 2023.
-
On Ambiguity in Linear Inverse Problems: Entrywise Bounds on Nearly Data-Consistent Solutions and Entrywise Condition Numbers
Authors:
Justin P. Haldar
Abstract:
Ill-posed linear inverse problems appear frequently in various signal processing applications. It can be very useful to have theoretical characterizations that quantify the level of ill-posedness for a given inverse problem and the degree of ambiguity that may exist about its solution. Traditional measures of ill-posedness, such as the condition number of a matrix, provide characterizations that a…
▽ More
Ill-posed linear inverse problems appear frequently in various signal processing applications. It can be very useful to have theoretical characterizations that quantify the level of ill-posedness for a given inverse problem and the degree of ambiguity that may exist about its solution. Traditional measures of ill-posedness, such as the condition number of a matrix, provide characterizations that are global in nature. While such characterizations can be powerful, they can also fail to provide full insight into situations where certain entries of the solution vector are more or less ambiguous than others. In this work, we derive novel theoretical lower- and upper-bounds that apply to individual entries of the solution vector, and are valid for all potential solution vectors that are nearly data-consistent. These bounds are agnostic to the noise statistics and the specific method used to solve the inverse problem, and are also shown to be tight. In addition, our results also lead us to introduce an entrywise version of the traditional condition number, which provides a substantially more nuanced characterization of scenarios where certain elements of the solution vector are less sensitive to perturbations than others. Our results are illustrated in an application to magnetic resonance imaging reconstruction, and we include discussions of practical computation methods for large-scale inverse problems, connections between our new theory and the traditional Cramér-Rao bound under statistical modeling assumptions, and potential extensions to cases involving constraints beyond just data-consistency.
△ Less
Submitted 27 December, 2022;
originally announced December 2022.
-
PALMNUT: An Enhanced Proximal Alternating Linearized Minimization Algorithm with Application to Separate Regularization of Magnitude and Phase
Authors:
Yunsong Liu,
Justin P. Haldar
Abstract:
We introduce a new algorithm for complex image reconstruction with separate regularization of the image magnitude and phase. This optimization problem is interesting in many different image reconstruction contexts, although is nonconvex and can be difficult to solve. In this work, we first describe a novel implementation of the previous proximal alternating linearized minization (PALM) algorithm t…
▽ More
We introduce a new algorithm for complex image reconstruction with separate regularization of the image magnitude and phase. This optimization problem is interesting in many different image reconstruction contexts, although is nonconvex and can be difficult to solve. In this work, we first describe a novel implementation of the previous proximal alternating linearized minization (PALM) algorithm to solve this optimization problem. We then make enhancements to PALM, leading to a new algorithm named PALMNUT that combines the PALM together with Nesterov's momentum and a novel approach that relies on uncoupled coordinatewise step sizes derived from coordinatewise Lipschitz-like bounds. Theoretically, we establish that a version of PALMNUT (without Nesterov's momentum) monotonically decreases the objective function, leading to guaranteed convergence in many cases of interest. Empirical results obtained in the context of magnetic resonance imaging demonstrate that PALMNUT has computational advantages over common existing approaches like alternating minimization. Although our focus is on the application to separate magnitude and phase regularization, we expect that the same approach may also be useful in other nonconvex optimization problems with similar objective function structure.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
Efficient Iterative Solutions to Complex-Valued Nonlinear Least-Squares Problems with Mixed Linear and Antilinear Operators
Authors:
Tae Hyung Kim,
Justin P. Haldar
Abstract:
We consider a setting in which it is desired to find an optimal complex vector $\mathbf{x}\in\mathbb{C}^N$ that satisfies $\mathcal{A}(\mathbf{x}) \approx \mathbf{b}$ in a least-squares sense, where $\mathbf{b} \in \mathbb{C}^M$ is a data vector (possibly noise-corrupted), and $\mathcal{A}(\cdot): \mathbb{C}^N \rightarrow \mathbb{C}^M$ is a measurement operator. If $\mathcal{A}(\cdot)$ were linear…
▽ More
We consider a setting in which it is desired to find an optimal complex vector $\mathbf{x}\in\mathbb{C}^N$ that satisfies $\mathcal{A}(\mathbf{x}) \approx \mathbf{b}$ in a least-squares sense, where $\mathbf{b} \in \mathbb{C}^M$ is a data vector (possibly noise-corrupted), and $\mathcal{A}(\cdot): \mathbb{C}^N \rightarrow \mathbb{C}^M$ is a measurement operator. If $\mathcal{A}(\cdot)$ were linear, this reduces to the classical linear least-squares problem, which has a well-known analytic solution as well as powerful iterative solution algorithms. However, instead of linear least-squares, this work considers the more complicated scenario where $\mathcal{A}(\cdot)$ is nonlinear, but can be represented as the summation and/or composition of some operators that are linear and some operators that are antilinear. Some common nonlinear operations that have this structure include complex conjugation or taking the real-part or imaginary-part of a complex vector. Previous literature has shown that this kind of mixed linear/antilinear least-squares problem can be mapped into a linear least-squares problem by considering $\mathbf{x}$ as a vector in $\mathbb{R}^{2N}$ instead of $\mathbb{C}^N$. While this approach is valid, the replacement of the original complex-valued optimization problem with a real-valued optimization problem can be complicated to implement, and can also be associated with increased computational complexity. In this work, we describe theory and computational methods that enable mixed linear/antilinear least-squares problems to be solved iteratively using standard linear least-squares tools, while retaining all of the complex-valued structure of the original inverse problem. An illustration is provided to demonstrate that this approach can simplify the implementation and reduce the computational complexity of iterative solution algorithms.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Optimal Sampling & Reconstruction: Theory and Applications
Authors:
Justin P. Haldar
Abstract:
The optimization of MRI data sampling and image reconstruction methods has been a priority for the MRI community since the very early days of the field. Designing an "optimal" method requires the definition of an optimality metric (i.e., a quantitative evaluation of the "goodness" of different competing approaches that allows an objective comparison between them). However, a key challenge is that…
▽ More
The optimization of MRI data sampling and image reconstruction methods has been a priority for the MRI community since the very early days of the field. Designing an "optimal" method requires the definition of an optimality metric (i.e., a quantitative evaluation of the "goodness" of different competing approaches that allows an objective comparison between them). However, a key challenge is that there are many different possible ways of quantitatively evaluating the "goodness" of a data sampling scheme or a reconstruction result, and there are no acquisition or reconstruction methods that are known to be universally optimal with respect to all of these possible metrics simultaneously. Thus, optimization of MRI methods requires a subjective choice about what aspects of quality matter most in the context of a given MRI experiment, and subsequently the subjective choice of an optimality metric that hopefully does a reasonable job of quantifying those aspects of quality. Once these choices are made, the optimization problem becomes well-defined, and it remains to choose an algorithm that can identify data sampling or image reconstruction methods that are optimal with respect to the chosen metric. All of these choices are generally nontrivial.
In this presentation, we will discuss optimal sampling and reconstruction designs from multiple different perspectives, including ideas from information and estimation theory and various practical perspectives.
△ Less
Submitted 21 November, 2019;
originally announced November 2019.
-
Fast Sub-millimeter Diffusion MRI using gSlider-SMS and SNR-Enhancing Joint Reconstruction
Authors:
Justin P. Haldar,
Qiuyun Fan,
Kawin Setsompop
Abstract:
We evaluate a new approach for achieving diffusion MRI data with high spatial resolution, large volume coverage, and fast acquisition speed.
A recent method called gSlider-SMS enables whole-brain sub-millimeter diffusion MRI with high signal-to-noise ratio (SNR) efficiency. However, despite the efficient acquisition, the resulting images can still suffer from low SNR due to the small size of the…
▽ More
We evaluate a new approach for achieving diffusion MRI data with high spatial resolution, large volume coverage, and fast acquisition speed.
A recent method called gSlider-SMS enables whole-brain sub-millimeter diffusion MRI with high signal-to-noise ratio (SNR) efficiency. However, despite the efficient acquisition, the resulting images can still suffer from low SNR due to the small size of the imaging voxels. This work proposes to mitigate the SNR problem by combining gSlider-SMS with a regularized SNR-enhancing reconstruction approach.
Illustrative results show that, from gSlider-SMS data acquired over a span of only 25 minutes on a 3T scanner, the proposed method is able to produce 71 MRI images (64 diffusion encoding orientations with $b=$1500 s/mm$^2$, and 7 images without diffusion weighting) of the entire \emph{in vivo} human brain with nominal 0.66 mm spatial resolution. Using data acquired from 75 minutes of acquisition as a gold standard reference, we demonstrate that the proposed SNR-ehancement procedure leads to substantial improvements in estimated diffusion parameters compared to conventional gSlider reconstruction. Results also demonstrate that the proposed method has advantages relative to denoising methods based on low-rank matrix modeling. A theoretical analysis of the trade-off between spatial resolution and SNR suggests that the proposed approach has high efficiency.
The combination of gSlider-SMS with advanced regularized reconstruction enables high-resolution quantitative diffusion MRI from a relatively fast acquisition.
△ Less
Submitted 15 August, 2019;
originally announced August 2019.
-
Robust Autocalibrated Structured Low-Rank EPI Ghost Correction
Authors:
Rodrigo A. Lobos,
W. Scott Hoge,
Ahsan Javed,
Congyu Liao,
Kawin Setsompop,
Krishna S. Nayak,
Justin P. Haldar
Abstract:
Purpose: We propose and evaluate a new structured low-rank method for EPI ghost correction called Robust Autocalibrated LORAKS (RAC-LORAKS). The method can be used to suppress EPI ghosts arising from the differences between different readout gradient polarities and/or the differences between different shots. It does not require conventional EPI navigator signals, and is robust to imperfect autocal…
▽ More
Purpose: We propose and evaluate a new structured low-rank method for EPI ghost correction called Robust Autocalibrated LORAKS (RAC-LORAKS). The method can be used to suppress EPI ghosts arising from the differences between different readout gradient polarities and/or the differences between different shots. It does not require conventional EPI navigator signals, and is robust to imperfect autocalibration data.
Methods: Autocalibrated LORAKS is a previous structured low-rank method for EPI ghost correction that uses GRAPPA-type autocalibration data to enable high-quality ghost correction. This method works well when the autocalibration data is pristine, but performance degrades substantially when the autocalibration information is imperfect. RAC-LORAKS generalizes Autocalibrated LORAKS in two ways. First, it does not completely trust the information from autocalibration data, and instead considers the autocalibration and EPI data simultaneously when estimating low-rank matrix structure. And second, it uses complementary information from the autocalibration data to improve EPI reconstruction in a multi-contrast joint reconstruction framework. RAC-LORAKS is evaluated using simulations and in vivo data, including comparisons to state-of-the-art methods.
Results: RAC-LORAKS is demonstrated to have good ghost elimination performance compared to state-of-the-art methods in several complicated EPI acquisition scenarios (including gradient-echo brain imaging, diffusion-encoded brain imaging, and cardiac imaging).
Conclusion: RAC-LORAKS provides effective suppression of EPI ghosts and is robust to imperfect autocalibration data.
△ Less
Submitted 1 October, 2020; v1 submitted 30 July, 2019;
originally announced July 2019.
-
LORAKI: Autocalibrated Recurrent Neural Networks for Autoregressive MRI Reconstruction in k-Space
Authors:
Tae Hyung Kim,
Pratyush Garg,
Justin P. Haldar
Abstract:
We propose and evaluate a new MRI reconstruction method named LORAKI that trains an autocalibrated scan-specific recurrent neural network (RNN) to recover missing k-space data. Methods like GRAPPA, SPIRiT, and AC-LORAKS assume that k-space data has shift-invariant autoregressive structure, and that the scan-specific autoregression relationships needed to recover missing samples can be learned from…
▽ More
We propose and evaluate a new MRI reconstruction method named LORAKI that trains an autocalibrated scan-specific recurrent neural network (RNN) to recover missing k-space data. Methods like GRAPPA, SPIRiT, and AC-LORAKS assume that k-space data has shift-invariant autoregressive structure, and that the scan-specific autoregression relationships needed to recover missing samples can be learned from fully-sampled autocalibration (ACS) data. Recently, the structure of the linear GRAPPA method has been translated into a nonlinear deep learning method named RAKI. RAKI uses ACS data to train an artificial neural network to interpolate missing k-space samples, and often outperforms GRAPPA. In this work, we apply a similar principle to translate the linear AC-LORAKS method (simultaneously incorporating support, phase, and parallel imaging constraints) into a nonlinear deep learning method named LORAKI. Since AC-LORAKS is iterative and convolutional, LORAKI takes the form of a convolutional RNN. This new architecture admits a wide range of sampling patterns, and even calibrationless patterns are possible if synthetic ACS data is generated. The performance of LORAKI was evaluated with retrospectively undersampled brain datasets, with comparisons against other related reconstruction methods. Results suggest that LORAKI can provide improved reconstruction compared to other scan-specific autocalibrated reconstruction methods like GRAPPA, RAKI, and AC-LORAKS. LORAKI offers a new deep-learning approach to MRI reconstruction based on RNNs in k-space, and enables improved image quality and enhanced sampling flexibility.
△ Less
Submitted 23 April, 2019; v1 submitted 19 April, 2019;
originally announced April 2019.
-
Linear Predictability in MRI Reconstruction: Leveraging Shift-Invariant Fourier Structure for Faster and Better Imaging
Authors:
Justin P. Haldar,
Kawin Setsompop
Abstract:
Over the past several decades, many different types of computational imaging approaches have been proposed for improving MRI. In this paper, we provide an overview of methods that assume that MRI Fourier data is linearly predictable. Linear prediction is well known in signal processing and may be most recognizable for its usefulness in speech processing and spectrum estimation applications. In MRI…
▽ More
Over the past several decades, many different types of computational imaging approaches have been proposed for improving MRI. In this paper, we provide an overview of methods that assume that MRI Fourier data is linearly predictable. Linear prediction is well known in signal processing and may be most recognizable for its usefulness in speech processing and spectrum estimation applications. In MRI, linear predictability implies that data can be sampled below the conventional Nyquist rate, since unmeasured data may be imputed as a shift-invariant linear combination of measured samples. Linear predictive methods include some of the earliest methods in the computational MRI reconstruction field, some of the most widely utilized computational MRI methods in modern clinical practice, and some of the most flexible and versatile modern computational imaging approaches that are enabling unprecedented new styles of data acquisition. In addition, the concept of linear predictability can be used to unify a number of more classical MRI reconstruction constraints, but without needing to make the strong assumptions of classical constrained reconstruction methods.
△ Less
Submitted 18 June, 2019; v1 submitted 7 March, 2019;
originally announced March 2019.
-
Multidimensional Correlation Spectroscopic Imaging of Exponential Decays: From Theoretical Principles to In Vivo Human Applications
Authors:
Daeun Kim,
Jessica L. Wisnowski,
Christopher T. Nguyen,
Justin P. Haldar
Abstract:
Multiexponential modeling of relaxation or diffusion MR signal decays is a popular approach for estimating and spatially map** different microstructural tissue compartments. While this approach can be quite powerful, it is also limited by the fact that one-dimensional multiexponential modeling is an ill-posed inverse problem with substantial ambiguities. In this paper, we present an overview of…
▽ More
Multiexponential modeling of relaxation or diffusion MR signal decays is a popular approach for estimating and spatially map** different microstructural tissue compartments. While this approach can be quite powerful, it is also limited by the fact that one-dimensional multiexponential modeling is an ill-posed inverse problem with substantial ambiguities. In this paper, we present an overview of a recent multidimensional correlation spectroscopic imaging approach to this problem. This approach helps to alleviate ill-posedness by leveraging multidimensional contrast encoding (e.g., 2D diffusion-relaxation encoding or 2D relaxation-relaxation encoding) combined with a regularized spatial-spectral estimation procedure. Theoretical calculations, simulations, and experimental results are used to illustrate the benefits of this approach relative to classical methods. In addition, we demonstrate an initial proof-of-principle application of this kind of approach to in vivo human MRI experiments.
△ Less
Submitted 8 May, 2019; v1 submitted 14 June, 2018;
originally announced June 2018.
-
Accelerated Wirtinger Flow: A fast algorithm for ptychography
Authors:
Rui Xu,
Mahdi Soltanolkotabi,
Justin P. Haldar,
Walter Unglaub,
Joshua Zusman,
Anthony F. J. Levi,
Richard M. Leahy
Abstract:
This paper presents a new algorithm, Accelerated Wirtinger Flow (AWF), for ptychographic image reconstruction from phaseless diffraction pattern measurements. AWF is based on combining Nesterov's acceleration approach with Wirtinger gradient descent. Theoretical results enable prespecification of all AWF algorithm parameters, with no need for computationally-expensive line searches and no need for…
▽ More
This paper presents a new algorithm, Accelerated Wirtinger Flow (AWF), for ptychographic image reconstruction from phaseless diffraction pattern measurements. AWF is based on combining Nesterov's acceleration approach with Wirtinger gradient descent. Theoretical results enable prespecification of all AWF algorithm parameters, with no need for computationally-expensive line searches and no need for manual parameter tuning. AWF is evaluated in the context of simulated X-ray ptychography, where we demonstrate fast convergence and low per-iteration computational complexity. We also show examples where AWF reaches higher image quality with less computation than classical algorithms. AWF is also shown to have robustness to noise and probe misalignment.
△ Less
Submitted 13 June, 2018;
originally announced June 2018.
-
OEDIPUS: An Experiment Design Framework for Sparsity-Constrained MRI
Authors:
Justin P. Haldar,
Daeun Kim
Abstract:
This paper introduces a new estimation-theoretic framework for experiment design in the context of MR image reconstruction under sparsity constraints. The new framework is called OEDIPUS (Oracle-based Experiment Design for Imaging Parsimoniously Under Sparsity constraints), and is based on combining the constrained Cramér-Rao bound with classical experiment design techniques. Compared to popular r…
▽ More
This paper introduces a new estimation-theoretic framework for experiment design in the context of MR image reconstruction under sparsity constraints. The new framework is called OEDIPUS (Oracle-based Experiment Design for Imaging Parsimoniously Under Sparsity constraints), and is based on combining the constrained Cramér-Rao bound with classical experiment design techniques. Compared to popular random sampling approaches, OEDIPUS is fully deterministic and automatically tailors the sampling pattern to the specific imaging context of interest (i.e., accounting for coil geometry, anatomy, image contrast, etc.). OEDIPUS-based experiment designs are evaluated using retrospectively subsampled in vivo MRI data in several different contexts. Results demonstrate that OEDIPUS-based experiment designs have some desirable characteristics relative to conventional MRI sampling approaches.
△ Less
Submitted 4 January, 2019; v1 submitted 1 May, 2018;
originally announced May 2018.
-
Optimal Experiment Design for Magnetic Resonance Fingerprinting: Cramér-Rao Bound Meets Spin Dynamics
Authors:
Bo Zhao,
Justin P. Haldar,
Congyu Liao,
Dan Ma,
Yun Jiang,
Mark A. Griswold,
Kawin Setsompop,
Lawrence L. Wald
Abstract:
Magnetic resonance (MR) fingerprinting is a new quantitative imaging paradigm, which simultaneously acquires multiple MR tissue parameter maps in a single experiment. In this paper, we present an estimation-theoretic framework to perform experiment design for MR fingerprinting. Specifically, we describe a discrete-time dynamic system to model spin dynamics, and derive an estimation-theoretic bound…
▽ More
Magnetic resonance (MR) fingerprinting is a new quantitative imaging paradigm, which simultaneously acquires multiple MR tissue parameter maps in a single experiment. In this paper, we present an estimation-theoretic framework to perform experiment design for MR fingerprinting. Specifically, we describe a discrete-time dynamic system to model spin dynamics, and derive an estimation-theoretic bound, i.e., the Cramer-Rao bound (CRB), to characterize the signal-to-noise ratio (SNR) efficiency of an MR fingerprinting experiment. We then formulate an optimal experiment design problem, which determines a sequence of acquisition parameters to encode MR tissue parameters with the maximal SNR efficiency, while respecting the physical constraints and other constraints from the image decoding/reconstruction process. We evaluate the performance of the proposed approach with numerical simulations, phantom experiments, and in vivo experiments. We demonstrate that the optimized experiments substantially reduce data acquisition time and/or improve parameter estimation. For example, the optimized experiments achieve about a factor of two improvement in the accuracy of $T_2$ maps, while kee** similar or slightly better accuracy of $T_1$ maps. Finally, as a remarkable observation, we find that the sequence of optimized acquisition parameters appears to be highly structured rather than randomly/pseudo-randomly varying as is prescribed in the conventional MR fingerprinting experiments.
△ Less
Submitted 1 October, 2018; v1 submitted 22 October, 2017;
originally announced October 2017.