-
Data-driven regularization parameter selection in dynamic MRI
Authors:
Matti Hanhela,
Olli Gröhn,
Mikko Kettunen,
Kati Niinimäki,
Marko Vauhkonen,
Ville Kolehmainen
Abstract:
In dynamic MRI, sufficient time resolution can often only be obtained using imaging protocols which produce undersampled data for each image in the time series. This has led to the popularity of compressed sensing (CS) based image reconstruction approaches. One of the problems in CS approaches is determining the regularization parameters, which control the balance between data fidelity the spatial…
▽ More
In dynamic MRI, sufficient time resolution can often only be obtained using imaging protocols which produce undersampled data for each image in the time series. This has led to the popularity of compressed sensing (CS) based image reconstruction approaches. One of the problems in CS approaches is determining the regularization parameters, which control the balance between data fidelity the spatial and temporal regularization terms. A data-driven approach is proposed for the total variation regularization parameter selection such that the reconstructions yield expected sparsity levels in the regularization domains. The expected sparsity levels are obtained from the measurement data for the temporal regularization and from a reference image for the spatial regularization. Two formulations are proposed. The first is a 2D search for a parameter pair which produces expected sparsity in both the temporal and spatial regularization domains. In the second approach, the sparsity-based parameter selection is split to two 1D searches using the S-curve method. The approaches are evaluated using simulated and experimental DCE-MRI. In the simulated test case, both proposed methods produce a parameter pair that is close to the RMSE optimal pair, and the reconstruction error is also close to minimum. In the experimental test case, the methods produce almost similar parameter selection, and the reconstructions are of high perceived quality. Both approaches lead to a highly feasible selection of the temporal and spatial regularization parameters in both the simulated and experimental test cases while the sequential method is computationally more efficient.
△ Less
Submitted 25 November, 2020; v1 submitted 3 April, 2020;
originally announced April 2020.
-
Temporal Huber regularization for DCE-MRI
Authors:
Matti Hanhela,
Mikko Kettunen,
Olli Gröhn,
Marko Vauhkonen,
Ville Kolehmainen
Abstract:
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to study microvascular structure and tissue perfusion. In DCE-MRI a bolus of gadolinium based contrast agent is injected into the blood stream and spatiotemporal changes induced by the contrast agent flow are estimated from a time series of MRI data. Sufficient time resolution can often only be obtained by using an imaging prot…
▽ More
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to study microvascular structure and tissue perfusion. In DCE-MRI a bolus of gadolinium based contrast agent is injected into the blood stream and spatiotemporal changes induced by the contrast agent flow are estimated from a time series of MRI data. Sufficient time resolution can often only be obtained by using an imaging protocol which produces undersampled data for each image in the time series. This has led to the popularity of compressed sensing based image reconstruction approaches, where all the images in the time series are reconstructed simultaneously, and temporal coupling between the images is introduced into the problem by a sparsity promoting regularization functional. We propose the use of Huber penalty for temporal regularization in DCE-MRI, and compare it to total variation, total generalized variation and smoothness based temporal regularization models. We also study the effect of spatial regularization to the reconstruction and compare the reconstruction accuracy with different temporal resolutions due to varying undersampling. The approaches are tested using simulated and experimental radial golden angle DCE-MRI data from a rat brain specimen. The results indicate that Huber regularization produces similar reconstruction accuracy with the total variation based models, but the computation times are significantly faster.
△ Less
Submitted 21 September, 2020; v1 submitted 19 March, 2020;
originally announced March 2020.
-
RatLesNetv2: A Fully Convolutional Network for Rodent Brain Lesion Segmentation
Authors:
Juan Miguel Valverde,
Artem Shatillo,
Riccardo de Feo,
Olli Gröhn,
Alejandra Sierra,
Jussi Tohka
Abstract:
We present a fully convolutional neural network (ConvNet), named RatLesNetv2, for segmenting lesions in rodent magnetic resonance (MR) brain images. RatLesNetv2 architecture resembles an autoencoder and it incorporates residual blocks that facilitate its optimization. RatLesNetv2 is trained end to end on three-dimensional images and it requires no preprocessing. We evaluated RatLesNetv2 on an exce…
▽ More
We present a fully convolutional neural network (ConvNet), named RatLesNetv2, for segmenting lesions in rodent magnetic resonance (MR) brain images. RatLesNetv2 architecture resembles an autoencoder and it incorporates residual blocks that facilitate its optimization. RatLesNetv2 is trained end to end on three-dimensional images and it requires no preprocessing. We evaluated RatLesNetv2 on an exceptionally large dataset composed of 916 T2-weighted rat brain MRI scans of 671 rats at nine different lesion stages that were used to study focal cerebral ischemia for drug development. In addition, we compared its performance with three other ConvNets specifically designed for medical image segmentation. RatLesNetv2 obtained similar to higher Dice coefficient values than the other ConvNets and it produced much more realistic and compact segmentations with notably fewer holes and lower Hausdorff distance. The Dice scores of RatLesNetv2 segmentations also exceeded inter-rater agreement of manual segmentations. In conclusion, RatLesNetv2 could be used for automated lesion segmentation, reducing human workload and improving reproducibility. RatLesNetv2 is publicly available at https://github.com/jmlipman/RatLesNetv2.
△ Less
Submitted 30 December, 2020; v1 submitted 24 January, 2020;
originally announced January 2020.
-
Automatic Rodent Brain MRI Lesion Segmentation with Fully Convolutional Networks
Authors:
Juan Miguel Valverde,
Artem Shatillo,
Riccardo de Feo,
Olli Gröhn,
Alejandra Sierra,
Jussi Tohka
Abstract:
Manual segmentation of rodent brain lesions from magnetic resonance images (MRIs) is an arduous, time-consuming and subjective task that is highly important in pre-clinical research. Several automatic methods have been developed for different human brain MRI segmentation, but little research has targeted automatic rodent lesion segmentation. The existing tools for performing automatic lesion segme…
▽ More
Manual segmentation of rodent brain lesions from magnetic resonance images (MRIs) is an arduous, time-consuming and subjective task that is highly important in pre-clinical research. Several automatic methods have been developed for different human brain MRI segmentation, but little research has targeted automatic rodent lesion segmentation. The existing tools for performing automatic lesion segmentation in rodents are constrained by strict assumptions about the data. Deep learning has been successfully used for medical image segmentation. However, there has not been any deep learning approach specifically designed for tackling rodent brain lesion segmentation. In this work, we propose a novel Fully Convolutional Network (FCN), RatLesNet, for the aforementioned task. Our dataset consists of 131 T2-weighted rat brain scans from 4 different studies in which ischemic stroke was induced by transient middle cerebral artery occlusion. We compare our method with two other 3D FCNs originally developed for anatomical segmentation (VoxResNet and 3D-U-Net) with 5-fold cross-validation on a single study and a generalization test, where the training was done on a single study and testing on three remaining studies. The labels generated by our method were quantitatively and qualitatively better than the predictions of the compared methods. The average Dice coefficient achieved in the 5-fold cross-validation experiment with the proposed approach was 0.88, between 3.7% and 38% higher than the compared architectures. The presented architecture also outperformed the other FCNs at generalizing on different studies, achieving the average Dice coefficient of 0.79.
△ Less
Submitted 23 August, 2019;
originally announced August 2019.