-
Experimental Investigation of Repurposed Kaplan Turbines as Variable-Speed Propellers for Maximizing Frequency Containment Reserve
Authors:
Francesco Gerini,
Elena Vagnoni,
Martin Seydoux,
Rachid Cherkaoui,
Mario Paolone
Abstract:
This study explores the practical viability of repurposing aging Kaplan turbines into variable-speed propellers by employing full-size frequency converters. The motivation behind this approach is to improve the provision of \emph{Frequency Containment Reserve} (FCR) while reducing fatigue in the Kaplan blades servomechanism. We evaluate the performance of these modified Kaplan turbines against the…
▽ More
This study explores the practical viability of repurposing aging Kaplan turbines into variable-speed propellers by employing full-size frequency converters. The motivation behind this approach is to improve the provision of \emph{Frequency Containment Reserve} (FCR) while reducing fatigue in the Kaplan blades servomechanism. We evaluate the performance of these modified Kaplan turbines against the one of another hydro asset composed of the same Kaplan turbine hybridized with a \emph{Battery Energy Storage System} (BESS). Experiments are conducted on a one-of-its-kind reduced-scale model testing platform. Our findings reveal that Kaplan turbines repurposed as variable-speed propellers exhibit similar dynamic response characteristics compared to the standalone Kaplan operation, with the added benefit of effectively eliminating blade movements. Furthermore, the ability to control the speed increases the hydraulic efficiency for certain operating points. In summary, investment in variable speed technology emerges as a viable alternative to BESS-based hydropower hybridization.
△ Less
Submitted 6 May, 2024;
originally announced May 2024.
-
Enhanced Frequency Containment Reserve Provision from Battery Hybridized Hydropower Plants: Theory and Experimental Validation
Authors:
Francesco Gerini,
Elena Vagnoni,
Martin Seydoux,
Rachid Cherkaoui,
Mario Paolone
Abstract:
This paper presents a solution to address wear and tear of Run-of-River (RoR) Hydropower Plants (HPPs) providing enhanced Frequency Containment Reserve (FCR). In this respect, the study proposes the integration of a Battery Energy Storage System (BESS) with RoR HPPs controlled by a double-layer Model Predictive Control (MPC). The upper layer MPC acts as a state of energy manager for the BESS, empl…
▽ More
This paper presents a solution to address wear and tear of Run-of-River (RoR) Hydropower Plants (HPPs) providing enhanced Frequency Containment Reserve (FCR). In this respect, the study proposes the integration of a Battery Energy Storage System (BESS) with RoR HPPs controlled by a double-layer Model Predictive Control (MPC). The upper layer MPC acts as a state of energy manager for the BESS, employing a forecast of the required regulating energy for the next hour. The lower-layer MPC optimally allocates the power set-point between the turbine and the BESS. Reduced-scale experiments are performed on a one-of-a-kind testing platform to validate the proposed MPC- based control considering a comparison with different control strategies and different BESS sizes. The results demonstrate superior performance of the proposed framework, compared to simpler techniques like dead-band control or to the standalone RoR scenario, leading to improved FCR provision, reduced servomechanism stress, and extended hydropower asset lifespan.
△ Less
Submitted 29 September, 2023; v1 submitted 27 September, 2023;
originally announced September 2023.
-
Optimal Grid-Forming Control of Battery Energy Storage Systems Providing Multiple Services: Modelling and Experimental Validation
Authors:
Francesco Gerini,
Yihui Zuo,
Rahul Gupta,
Elena Vagnoni,
Rachid Cherkaoui,
Mario Paolone
Abstract:
This paper proposes and experimentally validates a joint control and scheduling framework for a grid-forming converter-interfaced BESS providing multiple services to the electrical grid. The framework is designed to dispatch the operation of a distribution feeder hosting heterogeneous prosumers according to a dispatch plan and provide frequency containment reserve and voltage control as additional…
▽ More
This paper proposes and experimentally validates a joint control and scheduling framework for a grid-forming converter-interfaced BESS providing multiple services to the electrical grid. The framework is designed to dispatch the operation of a distribution feeder hosting heterogeneous prosumers according to a dispatch plan and provide frequency containment reserve and voltage control as additional services. The framework consists of three phases. In the day-ahead scheduling phase, a robust optimization problem is solved to compute the optimal dispatch plan and frequency droop coefficient, accounting for the uncertainty of the aggregated prosumption. In the intra-day phase, a model predictive control algorithm is used to compute the power set-point for the BESS to achieve the tracking of the dispatch plan. Finally, in a real-time stage, the power setpoint originated by the dispatch tracking is converted into a feasible frequency set-point for the grid forming converter by means of a convex optimisation problem accounting for the capability curve of the power converter. The proposed framework is experimentally validated by using a grid-scale 720 kVA/560 kWh BESS connected to a 20 kV distribution feeder of the EPFL hosting stochastic prosumption and PV generation.
△ Less
Submitted 19 October, 2021;
originally announced October 2021.
-
Local Effects of Grid-Forming Converters Providing Frequency Regulation to Bulk Power Grids
Authors:
Antonio Zecchino,
Francesco Gerini,
Yihui Zuo,
Rachid Cherkaoui,
Mario Paolone,
Elena Vagnoni
Abstract:
The progressive displacing of conventional generation in favour of renewable energy sources requires restoring an adequate capacity of regulating power to ensure reliable operation of power systems. Battery Energy Storage Systems (BESSs) are considered to be promising assets to restore suitable frequency regulation capacity levels. BESSs are typically connected to the grid with power-converters, a…
▽ More
The progressive displacing of conventional generation in favour of renewable energy sources requires restoring an adequate capacity of regulating power to ensure reliable operation of power systems. Battery Energy Storage Systems (BESSs) are considered to be promising assets to restore suitable frequency regulation capacity levels. BESSs are typically connected to the grid with power-converters, able to operate in either grid-forming or grid-following modes. This paper quantitatively assesses the impact on the local distribution grid of BESSs providing frequency regulation to bulk power systems. Specific metrics are proposed to compare the performance of grid-forming and grid-following control. Experimental results are obtained taking advantage of a 720 kVA/500 kWh BESS connected to the 20 kV distribution grid of the EPFL campus. The quantitative evaluation based on suitably proposed metrics confirms the superior performance of the grid-forming strategy, compared to the grid-following one.
△ Less
Submitted 11 October, 2021;
originally announced October 2021.