Dynamic Modeling and Control for an Offshore Semisubmersible Floating Wind Turbine
Authors:
Yingjie Gong,
Qinmin Yang,
Hua Geng,
Wenchao Meng,
Lin Wang
Abstract:
Floating wind turbines (FWTs) hold significant potential for the exploitation of offshore renewable energy resources. Nevertheless, prior to the construction of FWTs, it is imperative to tackle several critical challenges, especially the issue of performance degradation under combined wind and wave loads. This study initiates with the development of a simplified nonlinear dynamical model for a sem…
▽ More
Floating wind turbines (FWTs) hold significant potential for the exploitation of offshore renewable energy resources. Nevertheless, prior to the construction of FWTs, it is imperative to tackle several critical challenges, especially the issue of performance degradation under combined wind and wave loads. This study initiates with the development of a simplified nonlinear dynamical model for a semi-submersible FWT. In particular, both the rotor dynamics and the finite rotations of the platform are considered in presented modeling approach, thereby effectively capturing the complex interplay between the platform, tower, nacelle, and rotor under combined wind and wave loads. Subsequently, based on the developed FWT model, a novel adaptive nonlinear pitch controller is formulated with the goal of striking a trade-off between regulating power generation and reducing platform motion. Notably, the proposed control strategy adopts a continuous control approach, strategically beneficial in circumventing the chattering phenomenon commonly associated with sliding mode control. Furthermore, the controller integrates an online approximator and a robust integral of the sign of the tracking error, facilitating real-time learning of system unknown dynamics while compensating for bounded disturbances. Finally, both the accuracy of the established nonlinear FWT model in predicting key dynamics and the superiority of the presented pitch controller are validated through comprehensive comparative studies.
△ Less
Submitted 16 June, 2024;
originally announced June 2024.
-
Multi-Objective Sizing Optimization Method of Microgrid Considering Cost and Carbon Emissions
Authors:
Xiang Zhu,
Guangchun Ruan,
Hua Geng,
Honghai Liu,
Mingfei Bai,
Chao Peng
Abstract:
Microgrid serves as a promising solution to integrate and manage distributed renewable energy resources. In this paper, we establish a stochastic multi-objective sizing optimization (SMOSO) model for microgrid planning, which fully captures the battery degradation characteristics and the total carbon emissions. The microgrid operator aims to simultaneously maximize the economic benefits and minimi…
▽ More
Microgrid serves as a promising solution to integrate and manage distributed renewable energy resources. In this paper, we establish a stochastic multi-objective sizing optimization (SMOSO) model for microgrid planning, which fully captures the battery degradation characteristics and the total carbon emissions. The microgrid operator aims to simultaneously maximize the economic benefits and minimize carbon emissions, and the degradation of the battery energy storage system (BESS) is modeled as a nonlinear function of power throughput. A self-adaptive multi-objective genetic algorithm (SAMOGA) is proposed to solve the SMOSO model, and this algorithm is enhanced by pre-grouped hierarchical selection and self-adaptive probabilities of crossover and mutation. Several case studies are conducted to determine the microgrid size by analyzing Pareto frontiers, and the simulation results validate that the proposed method has superior performance over other algorithms on the solution quality of optimum and diversity.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
Dynamic Virtual Power Plants With Frequency Regulation Capacity
Authors:
Xiang Zhu,
Guangchun Ruan,
Hua Geng
Abstract:
For integrating heterogeneous distributed energy resources to provide fast frequency regulation, this paper proposes a dynamic virtual power plant~(DVPP) with frequency regulation capacity. A parameter anonymity-based approach is established for DVPP aggregating small-scaled inverter-based resources~(IBRs) with privacy concerns. On this basis, a parameter-to-performance map** is formulated to ev…
▽ More
For integrating heterogeneous distributed energy resources to provide fast frequency regulation, this paper proposes a dynamic virtual power plant~(DVPP) with frequency regulation capacity. A parameter anonymity-based approach is established for DVPP aggregating small-scaled inverter-based resources~(IBRs) with privacy concerns. On this basis, a parameter-to-performance map** is formulated to evaluate how control coefficients impact the DVPP-level power overshoot as well as the IBR-level costs. The objective is to design the best way to provide the frequency response with minimal impacts on grid and the most financial gains. Numerical experiments illustrate the effectiveness of the proposed approach and further analysis validates that our models are able to take dead bands into consideration.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Efficient Bilevel Source Mask Optimization
Authors:
Guo** Chen,
Hongquan He,
Peng Xu,
Hao Geng,
Bei Yu
Abstract:
Resolution Enhancement Techniques (RETs) are critical to meet the demands of advanced technology nodes. Among RETs, Source Mask Optimization (SMO) is pivotal, concurrently optimizing both the source and the mask to expand the process window. Traditional SMO methods, however, are limited by sequential and alternating optimizations, leading to extended runtimes without performance guarantees. This p…
▽ More
Resolution Enhancement Techniques (RETs) are critical to meet the demands of advanced technology nodes. Among RETs, Source Mask Optimization (SMO) is pivotal, concurrently optimizing both the source and the mask to expand the process window. Traditional SMO methods, however, are limited by sequential and alternating optimizations, leading to extended runtimes without performance guarantees. This paper introduces a unified SMO framework utilizing the accelerated Abbe forward imaging to enhance precision and efficiency. Further, we propose the innovative \texttt{BiSMO} framework, which reformulates SMO through a bilevel optimization approach, and present three gradient-based methods to tackle the challenges of bilevel SMO. Our experimental results demonstrate that \texttt{BiSMO} achieves a remarkable 40\% reduction in error metrics and 8$\times$ increase in runtime efficiency, signifying a major leap forward in SMO.
△ Less
Submitted 7 March, 2024;
originally announced May 2024.
-
Transient Stability of Low-Inertia Power Systems with Inverter-Based Generation
Authors:
Changjun He,
Xiuqiang He,
Hua Geng,
Huadong Sun,
Shiyun Xu
Abstract:
This study examines the transient stability of low-inertia power systems with inverter-based generation (IBG) and proposes a sufficient stability criterion. In low-inertia grids, transient interactions are induced between the electromagnetic dynamics of the IBG and the electromechanical dynamics of the synchronous generator (SG) under a fault. For this, a hybrid IBG-SG system is established and a…
▽ More
This study examines the transient stability of low-inertia power systems with inverter-based generation (IBG) and proposes a sufficient stability criterion. In low-inertia grids, transient interactions are induced between the electromagnetic dynamics of the IBG and the electromechanical dynamics of the synchronous generator (SG) under a fault. For this, a hybrid IBG-SG system is established and a delta-power-frequency model is developed. Based on this model, new mechanisms of transient instability different from those of conventional power systems from the energy perspective are discovered. First, two loss-of-synchronization (LOS) types are identified based on the relative power imbalance owing to the mismatch between the inertia of the IBG and SG under a fault. Second, the relative angle and frequency will jump at the moment of a fault, thus affecting the system energy. Third, the cosine dam** coefficient induces a positive energy dissipation, thereby contributing to the system stability. A unified criterion for identifying the two LOS types is proposed using the energy function method. This criterion is proved to be a sufficient stability condition for addressing the effects of the jumps and cosine dam** coefficient on the system stability. The new mechanisms and effectiveness of the criterion are verified based on simulation results.
△ Less
Submitted 21 April, 2022; v1 submitted 30 November, 2021;
originally announced November 2021.
-
Mode Clustering Based Dynamic Equivalent Modeling of Wind Farm for Small-Signal Stability Analysis
Authors:
Xiuqiang He,
Hua Geng,
Geng Yang
Abstract:
Dynamic equivalent models (DEMs) are necessities for the small-signal stability (SSS) analysis of the power system with large-scale wind farms (WFs). This paper proposes a mode clustering based dynamic equivalent modeling method of WFs for the SSS analysis. It is deemed that a DEM can be used to represent the whole WF to evaluate its impact on the SSS of power systems, as long as the frequency res…
▽ More
Dynamic equivalent models (DEMs) are necessities for the small-signal stability (SSS) analysis of the power system with large-scale wind farms (WFs). This paper proposes a mode clustering based dynamic equivalent modeling method of WFs for the SSS analysis. It is deemed that a DEM can be used to represent the whole WF to evaluate its impact on the SSS of power systems, as long as the frequency response of the DEM adequately matches that of the detailed WF model around the frequency of oscillation modes of concern. Focusing on the concerned oscillation modes in the small-signal model of the whole WF, closely distributed modes of them on the complex plane are classified into a cluster and then represented by a single mode. By the linear superposition principle, the modal participation factor (MPF) regarding each of modal clusters are superimposed, generating a feature vector for each wind turbine (WT). Based on the feature vectors, the oscillation feature similarity of the WTs as well as their aggregation can be evaluated and performed easily. Taking the DC-link voltage control (DVC) mode of full-power WT converters as an example, the aggregated DEM is verified by frequency-domain analyses and time-domain simulations.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
Transient Stability of Hybrid Power Systems Dominated by Different Types of Grid-Forming Devices
Authors:
Xiuqiang He,
Hua Geng
Abstract:
This paper investigates the transient stability of power systems co-dominated by different types of grid-forming (GFM) devices. Synchronous generators (SGs and VSGs) and droop-controlled inverters are typical GFM devices in modern power systems. SGs/VSGs are able to provide inertia while droop-controlled inverters are generally inertialess. The transient stability of power systems dominated by hom…
▽ More
This paper investigates the transient stability of power systems co-dominated by different types of grid-forming (GFM) devices. Synchronous generators (SGs and VSGs) and droop-controlled inverters are typical GFM devices in modern power systems. SGs/VSGs are able to provide inertia while droop-controlled inverters are generally inertialess. The transient stability of power systems dominated by homogeneous GFM devices has been extensively studied. Regarding the hybrid system jointly dominated by heterogeneous GFM devices, the transient stability is rarely reported. This paper aims to fill this gap. It is found that the synchronization behavior of the hybrid system can be described by a second-order motion equation, resembling the swing equation of SGs. Moreover, two significant differences from conventional power systems are discovered. The first is that the droop control dramatically enhances the dam** effect, greatly affecting the transient stability region. The second is that the frequency state variable exhibits a jump at the moment of fault disturbances, thus impacting the post-fault initial-state location and stability assessment. The underlying mechanism behind the two new characteristics is clarified and the impact on the transient stability performance is analyzed and verified. The findings provide new insights into transient stability of power systems hosting heterogeneous devices.
△ Less
Submitted 21 September, 2021; v1 submitted 21 April, 2021;
originally announced April 2021.
-
Synchronization Instability of Inverter-Based Generation During Asymmetrical Grid Faults
Authors:
Xiuqiang He,
Changjun He,
Sisi Pan,
Hua Geng,
Feng Liu
Abstract:
The transient stability of traditional power systems is concerned with the ability of generators to stay synchronized with the positive-sequence voltage of the network, whether for symmetrical or asymmetrical faults. In contrast, both positive- and negative-sequence synchronizations should be of concern for inverter-based generation (IBG) under asymmetrical faults. This is because the latest grid…
▽ More
The transient stability of traditional power systems is concerned with the ability of generators to stay synchronized with the positive-sequence voltage of the network, whether for symmetrical or asymmetrical faults. In contrast, both positive- and negative-sequence synchronizations should be of concern for inverter-based generation (IBG) under asymmetrical faults. This is because the latest grid codes stipulate that IBG should inject dual-sequence current when riding through asymmetrical faults. Currently, much less is known about the synchronization stability during asymmetrical faults. This significantly differs from the positive-sequence synchronization alone because the coupled dual-sequence synchronization is involved. This paper aims to fill this gap. Considering the sequence coupling under asymmetrical faults, the dual-sequence synchronization model of IBG is developed. Based on the model, the conditions that steady-state equilibrium points should follow are identified. The conditions throw light on the possible types of synchronization instability, including the positive-sequence dominated instability and the negative-sequence dominated one. For different types of instability, the dominant factors are analyzed quantitatively, which are reflected by the limit on the current injection amplitude. Exceeding the limit will lead to the loss of both positive- and negative-sequence synchronizations. The model and the analysis are verified by simulations and hardware-in-the-loop experiments.
△ Less
Submitted 22 July, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
SSUE: Simultaneous State and Uncertainty Estimation for Dynamical Systems
Authors:
Hang Geng,
Mulugeta A. Haile,
Huazhen Fang
Abstract:
Parameters of the mathematical model describing many practical dynamical systems are prone to vary due to aging or renewal, wear and tear, as well as changes in environmental or service conditions. These variabilities will adversely affect the accuracy of state estimation. In this paper, we introduce SSUE: Simultaneous State and Uncertainty Estimation for quantifying parameter uncertainty while si…
▽ More
Parameters of the mathematical model describing many practical dynamical systems are prone to vary due to aging or renewal, wear and tear, as well as changes in environmental or service conditions. These variabilities will adversely affect the accuracy of state estimation. In this paper, we introduce SSUE: Simultaneous State and Uncertainty Estimation for quantifying parameter uncertainty while simultaneously estimating the internal state of a system. Our approach involves the development of a Bayesian framework that recursively updates the posterior joint density of the unknown state vector and parameter uncertainty. To execute the framework for practical implementation, we develop a computational algorithm based on maximum a posteriori estimation and the numerical Newton's method. Observability analysis is conducted for linear systems, and its relation with the consistency of the estimation of the uncertainty's location is unveiled. Additional simulation results are provided to demonstrate the effectiveness of the proposed SSUE approach.
△ Less
Submitted 20 October, 2020;
originally announced October 2020.
-
Synchronization Stability Analysis and Enhancement of Grid-Tied Multi-Converter Systems
Authors:
Xiuqiang He,
Hua Geng
Abstract:
Synchronization instability of grid-tied converters during grid faults is a serious concern. For phase-locked loop (PLL) synchronized converters, synchronization stability during grid faults requires that PLL can resynchronize with the power grid. It is of great significance for meeting grid code specifications such as reactive current support. However, the synchronization in the context of high-i…
▽ More
Synchronization instability of grid-tied converters during grid faults is a serious concern. For phase-locked loop (PLL) synchronized converters, synchronization stability during grid faults requires that PLL can resynchronize with the power grid. It is of great significance for meeting grid code specifications such as reactive current support. However, the synchronization in the context of high-impedance weak grid is not always readily achieved. On one hand, the terminal voltage of converters is changeable due to being susceptible to the output current. One the other hand, there is interaction between multiple converters interconnected to the grid. Therefore, loss of synchronism (LOS) of converters during grid faults likely occurs. Previous research has investigated the LOS issue of single-converter infinite-bus (SCIB) system, but mostly overlooked the interaction between multiple converters. Previous efforts to address the issue of LOS are also in doubt for multi-converter systems. This paper develops a multi-converter infinite-bus (MCIB) system model and analyzes the root cause of LOS with considering multi-converter interaction during grid faults. Moreover, a feedforward compensated PLL (FFC-PLL) method applicable for multi-converter systems is developed to address the LOS issue. Simulations results verify the effectiveness of the method.
△ Less
Submitted 12 June, 2020;
originally announced June 2020.
-
Transient Stability of Power Systems Integrated With Inverter-Based Generation
Authors:
Xiuqiang He,
Hua Geng
Abstract:
The fundamental mechanism of transient stability of the conventional power system can be physically understood with the rotor swing dynamics of synchronous generators (SGs). The basic factor affecting the transient stability is the power-angle relationship among the SGs. The integration of a large number of inverter-based generations (IBGs) into the power system inevitably changes the original pow…
▽ More
The fundamental mechanism of transient stability of the conventional power system can be physically understood with the rotor swing dynamics of synchronous generators (SGs). The basic factor affecting the transient stability is the power-angle relationship among the SGs. The integration of a large number of inverter-based generations (IBGs) into the power system inevitably changes the original power-angle relationship, therefore leading to a more complicated transient stability mechanism. In this letter, the impact of IBG on the power system transient stability is analytically investigated. It is shown that the connection of IBG changes the original power-angle relationship into a nonsinusoidal curve, introduces a limit on the peak of the rotor swing, and therefore brings about a new bottleneck for the transient stability.
△ Less
Submitted 25 October, 2020; v1 submitted 3 June, 2020;
originally announced June 2020.