-
Classification of anomalous gait using Machine Learning techniques and embedded sensors
Authors:
T. R. D. Sa,
C. M. S. Figueiredo
Abstract:
Human gait can be a predictive factor for detecting pathologies that affect human locomotion according to studies. In addition, it is known that a high investment is demanded in order to raise a traditional clinical infrastructure able to provide human gait examinations, making them unaffordable for economically vulnerable patients. In face of this scenario, this work proposes an accessible and mo…
▽ More
Human gait can be a predictive factor for detecting pathologies that affect human locomotion according to studies. In addition, it is known that a high investment is demanded in order to raise a traditional clinical infrastructure able to provide human gait examinations, making them unaffordable for economically vulnerable patients. In face of this scenario, this work proposes an accessible and modern solution composed of a wearable device, to acquire 3D-accelerometer and 3D-gyroscope measurements, and machine learning techniques to classify between distinct categories of induced gait disorders. In order to develop the proposed research, it was created a dataset with the target label being 4 distinct and balanced categories of anomalous gait. The machine learning techniques that achieved the best performances (in terms of accuracy) in this dataset were through the application of Principal Component Analysis algorithm following of a Support Vector Machines classifier (94 \%). Further, an architecture based on a Feedforward Neural Network yielded even better results (96 \%). Finally, it is also presented computational performance comparison between the models implemented.
△ Less
Submitted 8 October, 2021;
originally announced October 2021.
-
A multicenter study on radiomic features from T$_2$-weighted images of a customized MR pelvic phantom setting the basis for robust radiomic models in clinics
Authors:
Linda Bianchini,
Joao Santinha,
Nuno Loução,
Mario Figueiredo,
Francesca Botta,
Daniela Origgi,
Marta Cremonesi,
Enrico Cassano,
Nikolaos Papanikolaou,
Alessandro Lascialfari
Abstract:
In this study we investigated the repeatability and reproducibility of radiomic features extracted from MRI images and provide a workflow to identify robust features. 2D and 3D T$_2$-weighted images of a pelvic phantom were acquired on three scanners of two manufacturers and two magnetic field strengths. The repeatability and reproducibility of the radiomic features were assessed respectively by i…
▽ More
In this study we investigated the repeatability and reproducibility of radiomic features extracted from MRI images and provide a workflow to identify robust features. 2D and 3D T$_2$-weighted images of a pelvic phantom were acquired on three scanners of two manufacturers and two magnetic field strengths. The repeatability and reproducibility of the radiomic features were assessed respectively by intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC), considering repeated acquisitions with or without phantom repositioning, and with different scanner/acquisition type, and acquisition parameters. The features showing ICC/CCC > 0.9 were selected, and their dependence on shape information (Spearman's $ρ$> 0.8) was analyzed. They were classified for their ability to distinguish textures, after shuffling voxel intensities. From 944 2D features, 79.9% to 96.4% showed excellent repeatability in fixed position across all scanners. Much lower range (11.2% to 85.4%) was obtained after phantom repositioning. 3D extraction did not improve repeatability performance. Excellent reproducibility between scanners was observed in 4.6% to 15.6% of the features, at fixed imaging parameters. 82.4% to 94.9% of features showed excellent agreement when extracted from images acquired with TEs 5 ms apart (values decreased when increasing TE intervals) and 90.7% of the features exhibited excellent reproducibility for changes in TR. 2.0% of non-shape features were identified as providing only shape information. This study demonstrates that radiomic features are affected by specific MRI protocols. The use of our radiomic pelvic phantom allowed to identify unreliable features for radiomic analysis on T$_2$-weighted images. This paper proposes a general workflow to identify repeatable, reproducible, and informative radiomic features, fundamental to ensure robustness of clinical studies.
△ Less
Submitted 18 May, 2020; v1 submitted 14 May, 2020;
originally announced May 2020.
-
SURE-fuse WFF: A Multi-resolution Windowed Fourier Analysis for Interferometric Phase Denoising
Authors:
Joshin P. Krishnan,
Mário A. T. Figueiredo,
José M. Bioucas-Dias
Abstract:
Interferometric phase (InPhase) imaging is an important part of many present-day coherent imaging technologies. Often in such imaging techniques, the acquired images, known as interferograms, suffer from two major degradations: 1) phase wrap** caused by the fact that the sensing mechanism can only measure sinusoidal $2π$-periodic functions of the actual phase, and 2) noise introduced by the acqu…
▽ More
Interferometric phase (InPhase) imaging is an important part of many present-day coherent imaging technologies. Often in such imaging techniques, the acquired images, known as interferograms, suffer from two major degradations: 1) phase wrap** caused by the fact that the sensing mechanism can only measure sinusoidal $2π$-periodic functions of the actual phase, and 2) noise introduced by the acquisition process or the system. This work focusses on InPhase denoising which is a fundamental restoration step to many posterior applications of InPhase, namely to phase unwrap**. The presence of sharp fringes that arises from phase wrap** makes InPhase denoising a hard-inverse problem. Motivated by the fact that the InPhase images are often locally sparse in Fourier domain, we propose a multi-resolution windowed Fourier filtering (WFF) analysis that fuses WFF estimates with different resolutions, thus overcoming the WFF fixed resolution limitation. The proposed fusion relies on an unbiased estimate of the mean square error derived using the Stein's lemma adapted to complex-valued signals. This estimate, known as SURE, is minimized using an optimization framework to obtain the fusion weights. Strong experimental evidence, using synthetic and real (InSAR & MRI) data, that the developed algorithm, termed as SURE-fuse WFF, outperforms the best hand-tuned fixed resolution WFF as well as other state-of-the-art InPhase denoising algorithms, is provided.
△ Less
Submitted 26 February, 2019; v1 submitted 9 November, 2018;
originally announced November 2018.
-
Impulsive Noise Robust Sparse Recovery via Continuous Mixed Norm
Authors:
Amirhossein Javaheri,
Hadi Zayyani,
Mario A. T. Figueiredo,
Farrokh Marvasti
Abstract:
This paper investigates the problem of sparse signal recovery in the presence of additive impulsive noise. The heavytailed impulsive noise is well modelled with stable distributions. Since there is no explicit formulation for the probability density function of $SαS$ distribution, alternative approximations like Generalized Gaussian Distribution (GGD) are used which impose $\ell_p$-norm fidelity o…
▽ More
This paper investigates the problem of sparse signal recovery in the presence of additive impulsive noise. The heavytailed impulsive noise is well modelled with stable distributions. Since there is no explicit formulation for the probability density function of $SαS$ distribution, alternative approximations like Generalized Gaussian Distribution (GGD) are used which impose $\ell_p$-norm fidelity on the residual error. In this paper, we exploit a Continuous Mixed Norm (CMN) for robust sparse recovery instead of $\ell_p$-norm. We show that in blind conditions, i.e., in case where the parameters of noise distribution are unknown, incorporating CMN can lead to near optimal recovery. We apply Alternating Direction Method of Multipliers (ADMM) for solving the problem induced by utilizing CMN for robust sparse recovery. In this approach, CMN is replaced with a surrogate function and Majorization-Minimization technique is incorporated to solve the problem. Simulation results confirm the efficiency of the proposed method compared to some recent algorithms in the literature for impulsive noise robust sparse recovery.
△ Less
Submitted 12 April, 2018;
originally announced April 2018.
-
Adaptive Consensus ADMM for Distributed Optimization
Authors:
Zheng Xu,
Gavin Taylor,
Hao Li,
Mario Figueiredo,
Xiaoming Yuan,
Tom Goldstein
Abstract:
The alternating direction method of multipliers (ADMM) is commonly used for distributed model fitting problems, but its performance and reliability depend strongly on user-defined penalty parameters. We study distributed ADMM methods that boost performance by using different fine-tuned algorithm parameters on each worker node. We present a O(1/k) convergence rate for adaptive ADMM methods with nod…
▽ More
The alternating direction method of multipliers (ADMM) is commonly used for distributed model fitting problems, but its performance and reliability depend strongly on user-defined penalty parameters. We study distributed ADMM methods that boost performance by using different fine-tuned algorithm parameters on each worker node. We present a O(1/k) convergence rate for adaptive ADMM methods with node-specific parameters, and propose adaptive consensus ADMM (ACADMM), which automatically tunes parameters without user oversight.
△ Less
Submitted 20 June, 2017; v1 submitted 9 June, 2017;
originally announced June 2017.