Dual Branch Prior-SegNet: CNN for Interventional CBCT using Planning Scan and Auxiliary Segmentation Loss
Authors:
Philipp Ernst,
Suhita Ghosh,
Georg Rose,
Andreas Nürnberger
Abstract:
This paper proposes an extension to the Dual Branch Prior-Net for sparse view interventional CBCT reconstruction incorporating a high quality planning scan. An additional head learns to segment interventional instruments and thus guides the reconstruction task. The prior scans are misaligned by up to +-5deg in-plane during training. Experiments show that the proposed model, Dual Branch Prior-SegNe…
▽ More
This paper proposes an extension to the Dual Branch Prior-Net for sparse view interventional CBCT reconstruction incorporating a high quality planning scan. An additional head learns to segment interventional instruments and thus guides the reconstruction task. The prior scans are misaligned by up to +-5deg in-plane during training. Experiments show that the proposed model, Dual Branch Prior-SegNet, significantly outperforms any other evaluated model by >2.8dB PSNR. It also stays robust wrt. rotations of up to +-5.5deg.
△ Less
Submitted 11 May, 2022;
originally announced May 2022.
-
Primal-Dual UNet for Sparse View Cone Beam Computed Tomography Volume Reconstruction
Authors:
Philipp Ernst,
Soumick Chatterjee,
Georg Rose,
Andreas Nürnberger
Abstract:
In this paper, the Primal-Dual UNet for sparse view CT reconstruction is modified to be applicable to cone beam projections and perform reconstructions of entire volumes instead of slices. Experiments show that the PSNR of the proposed method is increased by 10dB compared to the direct FDK reconstruction and almost 3dB compared to the modified original Primal-Dual Network when using only 23 projec…
▽ More
In this paper, the Primal-Dual UNet for sparse view CT reconstruction is modified to be applicable to cone beam projections and perform reconstructions of entire volumes instead of slices. Experiments show that the PSNR of the proposed method is increased by 10dB compared to the direct FDK reconstruction and almost 3dB compared to the modified original Primal-Dual Network when using only 23 projections. The presented network is not optimized wrt. memory consumption or hyperparameters but merely serves as a proof of concept and is limited to low resolution projections and volumes.
△ Less
Submitted 11 May, 2022;
originally announced May 2022.
-
Sinogram upsampling using Primal-Dual UNet for undersampled CT and radial MRI reconstruction
Authors:
Philipp Ernst,
Soumick Chatterjee,
Georg Rose,
Oliver Speck,
Andreas Nürnberger
Abstract:
Computed tomography and magnetic resonance imaging are two widely used clinical imaging modalities for non-invasive diagnosis. However, both of these modalities come with certain problems. CT uses harmful ionising radiation, and MRI suffers from slow acquisition speed. Both problems can be tackled by undersampling, such as sparse sampling. However, such undersampled data leads to lower resolution…
▽ More
Computed tomography and magnetic resonance imaging are two widely used clinical imaging modalities for non-invasive diagnosis. However, both of these modalities come with certain problems. CT uses harmful ionising radiation, and MRI suffers from slow acquisition speed. Both problems can be tackled by undersampling, such as sparse sampling. However, such undersampled data leads to lower resolution and introduces artefacts. Several techniques, including deep learning based methods, have been proposed to reconstruct such data. However, the undersampled reconstruction problem for these two modalities was always considered as two different problems and tackled separately by different research works. This paper proposes a unified solution for both sparse CT and undersampled radial MRI reconstruction, achieved by applying Fourier transform-based pre-processing on the radial MRI and then finally reconstructing both modalities using sinogram upsampling combined with filtered back-projection. The Primal-Dual network is a deep learning based method for reconstructing sparsely-sampled CT data. This paper introduces Primal-Dual UNet, which improves the Primal-Dual network in terms of accuracy and reconstruction speed. The proposed method resulted in an average SSIM of 0.932\textpm0.021 while performing sparse CT reconstruction for fan-beam geometry with a sparsity level of 16, achieving a statistically significant improvement over the previous model, which resulted in 0.919\textpm0.016. Furthermore, the proposed model resulted in 0.903\textpm0.019 and 0.957\textpm0.023 average SSIM while reconstructing undersampled brain and abdominal MRI data with an acceleration factor of 16, respectively - statistically significant improvements over the original model, which resulted in 0.867\textpm0.025 and 0.949\textpm0.025.
△ Less
Submitted 1 March, 2023; v1 submitted 26 December, 2021;
originally announced December 2021.
-
Dual Skip Connections Minimize the False Positive Rate of Lung Nodule Detection in CT images
Authors:
Jiahua Xu,
Philipp Ernst,
Tung Lung Liu,
Andreas Nürnberger
Abstract:
Pulmonary cancer is one of the most commonly diagnosed and fatal cancers and is often diagnosed by incidental findings on computed tomography. Automated pulmonary nodule detection is an essential part of computer-aided diagnosis, which is still facing great challenges and difficulties to quickly and accurately locate the exact nodules' positions. This paper proposes a dual skip connection upsampli…
▽ More
Pulmonary cancer is one of the most commonly diagnosed and fatal cancers and is often diagnosed by incidental findings on computed tomography. Automated pulmonary nodule detection is an essential part of computer-aided diagnosis, which is still facing great challenges and difficulties to quickly and accurately locate the exact nodules' positions. This paper proposes a dual skip connection upsampling strategy based on Dual Path network in a U-Net structure generating multiscale feature maps, which aims to minimize the ratio of false positives and maximize the sensitivity for lesion detection of nodules. The results show that our new upsampling strategy improves the performance by having 85.3% sensitivity at 4 FROC per image compared to 84.2% for the regular upsampling strategy or 81.2% for VGG16-based Faster-R-CNN.
△ Less
Submitted 25 October, 2021;
originally announced October 2021.
-
CHAOS Challenge -- Combined (CT-MR) Healthy Abdominal Organ Segmentation
Authors:
A. Emre Kavur,
N. Sinem Gezer,
Mustafa Barış,
Sinem Aslan,
Pierre-Henri Conze,
Vladimir Groza,
Duc Duy Pham,
Soumick Chatterjee,
Philipp Ernst,
Savaş Özkan,
Bora Baydar,
Dmitry Lachinov,
Shuo Han,
Josef Pauli,
Fabian Isensee,
Matthias Perkonigg,
Rachana Sathish,
Ronnie Rajan,
Debdoot Sheet,
Gurbandurdy Dovletov,
Oliver Speck,
Andreas Nürnberger,
Klaus H. Maier-Hein,
Gözde Bozdağı Akar,
Gözde Ünal
, et al. (2 additional authors not shown)
Abstract:
Segmentation of abdominal organs has been a comprehensive, yet unresolved, research field for many years. In the last decade, intensive developments in deep learning (DL) have introduced new state-of-the-art segmentation systems. In order to expand the knowledge on these topics, the CHAOS - Combined (CT-MR) Healthy Abdominal Organ Segmentation challenge has been organized in conjunction with IEEE…
▽ More
Segmentation of abdominal organs has been a comprehensive, yet unresolved, research field for many years. In the last decade, intensive developments in deep learning (DL) have introduced new state-of-the-art segmentation systems. In order to expand the knowledge on these topics, the CHAOS - Combined (CT-MR) Healthy Abdominal Organ Segmentation challenge has been organized in conjunction with IEEE International Symposium on Biomedical Imaging (ISBI), 2019, in Venice, Italy. CHAOS provides both abdominal CT and MR data from healthy subjects for single and multiple abdominal organ segmentation. Five different but complementary tasks have been designed to analyze the capabilities of current approaches from multiple perspectives. The results are investigated thoroughly, compared with manual annotations and interactive methods. The analysis shows that the performance of DL models for single modality (CT / MR) can show reliable volumetric analysis performance (DICE: 0.98 $\pm$ 0.00 / 0.95 $\pm$ 0.01) but the best MSSD performance remain limited (21.89 $\pm$ 13.94 / 20.85 $\pm$ 10.63 mm). The performances of participating models decrease significantly for cross-modality tasks for the liver (DICE: 0.88 $\pm$ 0.15 MSSD: 36.33 $\pm$ 21.97 mm) and all organs (DICE: 0.85 $\pm$ 0.21 MSSD: 33.17 $\pm$ 38.93 mm). Despite contrary examples on different applications, multi-tasking DL models designed to segment all organs seem to perform worse compared to organ-specific ones (performance drop around 5\%). Besides, such directions of further research for cross-modality segmentation would significantly support real-world clinical applications. Moreover, having more than 1500 participants, another important contribution of the paper is the analysis on shortcomings of challenge organizations such as the effects of multiple submissions and peeking phenomena.
△ Less
Submitted 7 January, 2021; v1 submitted 17 January, 2020;
originally announced January 2020.