-
Generalized Vector Locus Transformation for Unbalanced Three-Phase Systems
Authors:
Maitraya Avadhut Desai,
Francisco Escobar,
Gabriela Hug
Abstract:
Coordinate transformations significantly simplify power systems computations. Most notably, the classical Clarke and dq0 transformations are widely used in three-phase systems, as together they transform balanced abc quantities into constant-valued signals. However, during unbalanced operation, the utility of these transformations diminishes, since a null 0 coordinate cannot be ensured and oscilla…
▽ More
Coordinate transformations significantly simplify power systems computations. Most notably, the classical Clarke and dq0 transformations are widely used in three-phase systems, as together they transform balanced abc quantities into constant-valued signals. However, during unbalanced operation, the utility of these transformations diminishes, since a null 0 coordinate cannot be ensured and oscillating signals emerge. While recently proposed transformations ensure a null 0 coordinate, they still do not lead to constant-valued signals in the dq0 domain. In this letter, we propose a generalized vector locus transformation that ensures both a null 0 coordinate and constant-valued signals. Moreover, we show that, in the balanced case, the classical amplitude-invariant Clarke transformation is an instance of the proposed transformation.
△ Less
Submitted 21 June, 2024;
originally announced June 2024.
-
Cross-Forming Control and Fault Current Limiting for Grid-Forming Inverters
Authors:
Xiuqiang He,
Maitraya Avadhut Desai,
Linbin Huang,
Florian Dörfler
Abstract:
We propose a novel "cross-forming" control concept for grid-forming inverters operating against grid faults. Cross-forming refers to voltage angle forming and current magnitude forming, differing from classical grid-forming and grid-following concepts, i.e., voltage magnitude-and-angle forming and current magnitude-and-angle forming, respectively. Unlike purely grid-forming or grid-following parad…
▽ More
We propose a novel "cross-forming" control concept for grid-forming inverters operating against grid faults. Cross-forming refers to voltage angle forming and current magnitude forming, differing from classical grid-forming and grid-following concepts, i.e., voltage magnitude-and-angle forming and current magnitude-and-angle forming, respectively. Unlike purely grid-forming or grid-following paradigms, the cross-forming concept is motivated by device security requirements for fault current limitation and meanwhile grid code requirements for voltage angle forming preserving. We propose two feasible cross-forming control implementations, enabling inverters to quickly limit fault currents at a prescribed level and preserve voltage angle forming for grid-forming synchronization and dynamic ancillary services provision, during symmetrical or asymmetrical fault ride-through. Moreover, the cross-forming control yields an equivalent system featuring a constant virtual impedance and a "normal form" of representation, allowing us to extend previously established transient stability results to encompass scenarios of current saturation. Simulations and hardware experiments validate the efficacy of the proposed cross-forming control.
△ Less
Submitted 6 May, 2024; v1 submitted 20 April, 2024;
originally announced April 2024.
-
Saturation-Informed Current-Limiting Control for Grid-Forming Converters
Authors:
Maitraya Avadhut Desai,
Xiuqiang He,
Linbin Huang,
Florian Dörfler
Abstract:
In this paper, we investigate the transient stability of a state-of-the-art grid-forming complex-droop control (i.e., dispatchable virtual oscillator control, dVOC) under current saturation. We quantify the saturation level of a converter by introducing the concept of degree of saturation (DoS), and we propose a provably stable current-limiting control with saturation-informed feedback, which feed…
▽ More
In this paper, we investigate the transient stability of a state-of-the-art grid-forming complex-droop control (i.e., dispatchable virtual oscillator control, dVOC) under current saturation. We quantify the saturation level of a converter by introducing the concept of degree of saturation (DoS), and we propose a provably stable current-limiting control with saturation-informed feedback, which feeds the degree of saturation back to the inner voltage-control loop and the outer grid-forming loop. As a result, although the output current is saturated, the voltage phase angle can still be generated from an internal virtual voltage-source node that is governed by an equivalent complex-droop control. We prove that the proposed control achieves transient stability during current saturation under grid faults. We also provide parametric stability conditions for multi-converter systems under grid-connected and islanded scenarios. The stability performance of the current-limiting control is validated with various case studies.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.