-
Cellular EXchange Imaging (CEXI): Evaluation of a diffusion model including water exchange in cells using numerical phantoms of permeable spheres
Authors:
Rémy Gardier,
Juan Luis Villarreal Haro,
Erick J. Canales-Rodriguez,
Ileana O. Jelescu,
Gabriel Girard,
Jonathan Rafael-Patino,
Jean-Philippe Thiran
Abstract:
Purpose: Biophysical models of diffusion MRI have been developed to characterize microstructure in various tissues, but existing models are not suitable for tissue composed of permeable spherical cells. In this study we introduce Cellular Exchange Imaging (CEXI), a model tailored for permeable spherical cells, and compares its performance to a related Ball \& Sphere (BS) model that neglects permea…
▽ More
Purpose: Biophysical models of diffusion MRI have been developed to characterize microstructure in various tissues, but existing models are not suitable for tissue composed of permeable spherical cells. In this study we introduce Cellular Exchange Imaging (CEXI), a model tailored for permeable spherical cells, and compares its performance to a related Ball \& Sphere (BS) model that neglects permeability. Methods: We generated DW-MRI signals using Monte-Carlo simulations with a PGSE sequence in numerical substrates made of spherical cells and their extracellular space for a range of membrane permeability. From these signals, the properties of the substrates were inferred using both BS and CEXI models. Results: CEXI outperformed the impermeable model by providing more stable estimates cell size and intracellular volume fraction that were diffusion time-independent. Notably, CEXI accurately estimated the exchange time for low to moderate permeability levels previously reported in other studies ($κ<25μm/s$). However, in highly permeable substrates ($κ=50μm/s$), the estimated parameters were less stable, particularly the diffusion coefficients. Conclusion: This study highlights the importance of modeling the exchange time to accurately quantify microstructure properties in permeable cellular substrates. Future studies should evaluate CEXI in clinical applications such as lymph nodes, investigate exchange time as a potential biomarker of tumor severity, and develop more appropriate tissue models that account for anisotropic diffusion and highly permeable membranes.
△ Less
Submitted 7 June, 2023; v1 submitted 28 March, 2023;
originally announced March 2023.
-
Microstructure estimation from diffusion-MRI: Compartmentalized models in permeable cellular tissue
Authors:
Rémy Gardier,
Juan Luis Villarreal Haro,
Erick J Canales-Rodrıguez,
Ileana O. Jelescu,
Gabriel Girard,
Jonathan Rafael-Patino,
Jean-Philippe Thiran
Abstract:
Diffusion-weighted magnetic resonance imaging (DW-MRI) is used to characterize brain tissue microstructure employing tissue-specific biophysical models. A current limitation, however, is that most of the proposed models are based on the assumption of negligible water exchange between the intra- and extracellular compartments, which might not be valid in various brain tissues, including unmyelinate…
▽ More
Diffusion-weighted magnetic resonance imaging (DW-MRI) is used to characterize brain tissue microstructure employing tissue-specific biophysical models. A current limitation, however, is that most of the proposed models are based on the assumption of negligible water exchange between the intra- and extracellular compartments, which might not be valid in various brain tissues, including unmyelinated axons, gray matter, and tumors. The purpose of this work is to quantify the effect of membrane permeability on the estimates of two popular models neglecting exchange, and compare their performance with a model including exchange. To this aim, DW-MRI experiments were performed in controlled environments with Monte-Carlo simulations. The DW-MRI signals were generated in numerical substrates mimicking biological tissue made of spherical cells with permeable membranes like cancerous tissue or the brain gray matter. From these signals, the substrates properties were estimated using SANDI and VERDICT, the two compartment-based models neglecting exchange, and CEXI, a new model which includes exchange. Our results show that, in cellular permeable tissue, the model with exchange outperformed models without exchange in the estimation of the tissue properties by providing more stable estimates of cell size, intracellular volume fraction and extracellular diffusion coefficient. Moreover, the model with exchange estimated accurately the exchange time in the range of permeability reported for cellular tissue. Finally, the simulations performed in this work showed that the exchange between the intracellular and the extracellular space cannot be neglected in permeable tissue with a conventional PGSE sequence, to obtain accurate estimates. Consequently, existing compartmentalized models of impermeable tissue cannot be used for microstructure estimation of cellular permeable tissue.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
Slice estimation in diffusion MRI of neonatal and fetal brains in image and spherical harmonics domains using autoencoders
Authors:
Hamza Kebiri,
Gabriel Girard,
Yasser Aleman-Gomez,
Thomas Yu,
Andras Jakab,
Erick Jorge Canales-Rodriguez,
Meritxell Bach Cuadra
Abstract:
Diffusion MRI (dMRI) of the develo** brain can provide valuable insights into the white matter development. However, slice thickness in fetal dMRI is typically high (i.e., 3-5 mm) to freeze the in-plane motion, which reduces the sensitivity of the dMRI signal to the underlying anatomy. In this study, we aim at overcoming this problem by using autoencoders to learn unsupervised efficient represen…
▽ More
Diffusion MRI (dMRI) of the develo** brain can provide valuable insights into the white matter development. However, slice thickness in fetal dMRI is typically high (i.e., 3-5 mm) to freeze the in-plane motion, which reduces the sensitivity of the dMRI signal to the underlying anatomy. In this study, we aim at overcoming this problem by using autoencoders to learn unsupervised efficient representations of brain slices in a latent space, using raw dMRI signals and their spherical harmonics (SH) representation. We first learn and quantitatively validate the autoencoders on the develo** Human Connectome Project pre-term newborn data, and further test the method on fetal data. Our results show that the autoencoder in the signal domain better synthesized the raw signal. Interestingly, the fractional anisotropy and, to a lesser extent, the mean diffusivity, are best recovered in missing slices by using the autoencoder trained with SH coefficients. A comparison was performed with the same maps reconstructed using an autoencoder trained with raw signals, as well as conventional interpolation methods of raw signals and SH coefficients. From these results, we conclude that the recovery of missing/corrupted slices should be performed in the signal domain if the raw signal is aimed to be recovered, and in the SH domain if diffusion tensor properties (i.e., fractional anisotropy) are targeted. Notably, the trained autoencoders were able to generalize to fetal dMRI data acquired using a much smaller number of diffusion gradients and a lower b-value, where we qualitatively show the consistency of the estimated diffusion tensor maps.
△ Less
Submitted 28 August, 2022;
originally announced August 2022.
-
Axial and radial axonal diffusivities from single encoding strongly diffusion-weighted MRI
Authors:
Marco Pizzolato,
Erick Jorge Canales-Rodríguez,
Mariam Andersson,
Tim B. Dyrby
Abstract:
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the…
▽ More
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the sum of the contributions from axons. At the same time, spherical averaging leads to a major simplification of the modeling by removing the need to explicitly account for the unknown orientation distribution of axons. However, the spherically averaged signal acquired at strong diffusion weightings is not sensitive to the axial diffusivity, which cannot therefore be estimated. After revising existing theory, we introduce a new general method for the estimation of both axonal diffusivities at strong diffusion weightings based on zonal harmonics modeling. We additionally show how this could lead to estimates that are free from partial volume bias with, for instance, gray matter. We test the method on publicly available data from the MGH Adult Diffusion Human Connectome project dataset. We report reference values of axonal diffusivities based on 34 subjects, and derive estimates of axonal radii. We address the estimation problem also from the angle of the required data preprocessing, the presence of biases related to modeling assumptions, current limitations, and future possibilities.
△ Less
Submitted 6 July, 2022;
originally announced July 2022.
-
Validation and Generalizability of Self-Supervised Image Reconstruction Methods for Undersampled MRI
Authors:
Thomas Yu,
Tom Hilbert,
Gian Franco Piredda,
Arun Joseph,
Gabriele Bonanno,
Salim Zenkhri,
Patrick Omoumi,
Meritxell Bach Cuadra,
Erick Jorge Canales-Rodríguez,
Tobias Kober,
Jean-Philippe Thiran
Abstract:
Deep learning methods have become the state of the art for undersampled MR reconstruction. Particularly for cases where it is infeasible or impossible for ground truth, fully sampled data to be acquired, self-supervised machine learning methods for reconstruction are becoming increasingly used. However potential issues in the validation of such methods, as well as their generalizability, remain un…
▽ More
Deep learning methods have become the state of the art for undersampled MR reconstruction. Particularly for cases where it is infeasible or impossible for ground truth, fully sampled data to be acquired, self-supervised machine learning methods for reconstruction are becoming increasingly used. However potential issues in the validation of such methods, as well as their generalizability, remain underexplored. In this paper, we investigate important aspects of the validation of self-supervised algorithms for reconstruction of undersampled MR images: quantitative evaluation of prospective reconstructions, potential differences between prospective and retrospective reconstructions, suitability of commonly used quantitative metrics, and generalizability. Two self-supervised algorithms based on self-supervised denoising and the deep image prior were investigated. These methods are compared to a least squares fitting and a compressed sensing reconstruction using in-vivo and phantom data. Their generalizability was tested with prospectively under-sampled data from experimental conditions different to the training. We show that prospective reconstructions can exhibit significant distortion relative to retrospective reconstructions/ground truth. Furthermore, pixel-wise quantitative metrics may not capture differences in perceptual quality accurately, in contrast to a perceptual metric. In addition, all methods showed potential for generalization; however, generalizability is more affected by changes in anatomy/contrast than other changes. We further showed that no-reference image metrics correspond well with human rating of image quality for studying generalizability. Finally, we showed that a well-tuned compressed sensing reconstruction and learned denoising perform similarly on all data.
△ Less
Submitted 12 September, 2022; v1 submitted 29 January, 2022;
originally announced January 2022.
-
Multi-compartment diffusion MRI, T2 relaxometry and myelin water imaging as neuroimaging descriptors for anomalous tissue detection
Authors:
Elda Fischi-Gomez,
Jonathan Rafael-Patino,
Marco Pizzolato,
Gian Franco Piredda,
Tom Hilbert,
Tobias Kober,
Erick J. Canales-Rodriguez,
Jean-Philippe Thiran
Abstract:
Multiple sclerosis (MS) is an inflammatory and neurodegenerative disease characterized by diffuse and focal areas of tissue loss. Conventional MRI techniques such as T1-weighted and T2-weighted scans are generally used in the diagnosis and prognosis of the disease. Yet, these methods are limited by the lack of specificity between lesions, their perilesional area and non-lesional tissue. Alternativ…
▽ More
Multiple sclerosis (MS) is an inflammatory and neurodegenerative disease characterized by diffuse and focal areas of tissue loss. Conventional MRI techniques such as T1-weighted and T2-weighted scans are generally used in the diagnosis and prognosis of the disease. Yet, these methods are limited by the lack of specificity between lesions, their perilesional area and non-lesional tissue. Alternative MRI techniques exhibit a higher level of sensitivity to focal and diffuse MS pathology than conventional MRI acquisitions. However, they still suffer from limited specificity when considered alone. In this work, we have combined tissue microstructure information derived from multicompartment diffusion MRI and T2 relaxometry models to explore the voxel-based prediction power of a machine learning model in a cohort of MS patients and healthy controls. Our results show that the combination of multi-modal features, together with a boosting enhanced decision-tree based classifier, which combines a set of weak classifiers to form a strong classifier via a voting mechanism, is able to utilise the complementary information for the classification of abnormal tissue.
△ Less
Submitted 15 April, 2021;
originally announced April 2021.
-
Robust Monte-Carlo Simulations in Diffusion-MRI: Effect of the substrate complexity and parameter choice on the reproducibility of results
Authors:
Jonathan Rafael-Patino,
David Romascano,
Alonso Ramirez-Manzanares,
Erick Jorge Canales-Rodríguez,
Gabriel Girard,
Jean-Philippe Thiran
Abstract:
Monte-Carlo Diffusion Simulations (MCDS) have been used extensively as a ground truth tool for the validation of microstructure models for Diffusion-Weighted MRI. However, methodological pitfalls in the design of the biomimicking geometrical configurations and the simulation parameters can lead to approximation biases. Such pitfalls affect the reliability of the estimated signal, as well as its va…
▽ More
Monte-Carlo Diffusion Simulations (MCDS) have been used extensively as a ground truth tool for the validation of microstructure models for Diffusion-Weighted MRI. However, methodological pitfalls in the design of the biomimicking geometrical configurations and the simulation parameters can lead to approximation biases. Such pitfalls affect the reliability of the estimated signal, as well as its validity and reproducibility as ground truth data. In this work, we first present a set of experiments in order to study three critical pitfalls encountered in the design of MCDS in the literature, namely, the number of simulated particles and time steps, simplifications in the intra-axonal substrate representation, and the impact of the substrate's size on the signal stemming from the extra-axonal space. The results obtained show important changes in the simulated signals and the recovered microstructure features when changes in those parameters are introduced. Thereupon, driven by our findings from the first studies, we outline a general framework able to generate complex substrates. We show the framework's capability to overcome the aforementioned simplifications by generating a complex crossing substrate, which preserves the volume in the crossing area and achieves a high packing density. The results presented in this work,along with the simulator developed, pave the way towards more realistic and reproducible Monte-Carlo simulations for Diffusion-Weighted MRI.
△ Less
Submitted 13 November, 2019; v1 submitted 29 August, 2019;
originally announced August 2019.
-
Efficient sampling and robust 3D diffusion magnetic resonance imaging signal reconstruction
Authors:
Alice P. Bates,
Zubair Khalid,
Jason D. McEwen,
Rodney A. Kennedy,
Alessandro Daducci,
Erick J. Canales-Rodríguez
Abstract:
This paper presents novel single and multi-shell sampling schemes for diffusion MRI. In diffusion MRI, it is paramount that the number of samples is as small as possible in order that scan times are practical in a clinical setting. The proposed schemes use an efficient number of measurements in that the number of samples is equal to the degrees of freedom in the orthonormal bases used for reconstr…
▽ More
This paper presents novel single and multi-shell sampling schemes for diffusion MRI. In diffusion MRI, it is paramount that the number of samples is as small as possible in order that scan times are practical in a clinical setting. The proposed schemes use an efficient number of measurements in that the number of samples is equal to the degrees of freedom in the orthonormal bases used for reconstruction. Novel reconstruction algorithms based on smaller subsystems of linear equations, as compared to the standard regularized least-squares method, are developed for both single and multi-shells sampling schemes. The smaller matrices used in these novel reconstruction algorithms are designed to be well-conditioned, leading to improved reconstruction accuracy. Accurate and robust reconstruction is also achieved through incorporation of regularization into the novel reconstruction algorithms and using a Rician or non-central Chi noise model. We quantitatively validate our single and multi-shell schemes against standard least-squares reconstruction methods to show that they enable more accurate reconstruction when the number of samples is equal to the degrees of freedom in the basis. Human brain data is also used to qualitatively evaluate reconstruction
△ Less
Submitted 30 January, 2019; v1 submitted 25 July, 2018;
originally announced July 2018.