Skip to main content

Showing 1–3 of 3 results for author: Buist, M L

Searching in archive eess. Search in all archives.
.
  1. arXiv:2111.03997  [pdf

    eess.IV cs.AI cs.CV physics.med-ph

    The Three-Dimensional Structural Configuration of the Central Retinal Vessel Trunk and Branches as a Glaucoma Biomarker

    Authors: Satish K. Panda, Haris Cheong, Tin A. Tun, Thanadet Chuangsuwanich, Aiste Kadziauskiene, Vijayalakshmi Senthil, Ramaswami Krishnadas, Martin L. Buist, Shamira Perera, Ching-Yu Cheng, Tin Aung, Alexandre H. Thiery, Michael J. A. Girard

    Abstract: Purpose: To assess whether the three-dimensional (3D) structural configuration of the central retinal vessel trunk and its branches (CRVT&B) could be used as a diagnostic marker for glaucoma. Method: We trained a deep learning network to automatically segment the CRVT&B from the B-scans of the optical coherence tomography (OCT) volume of the optic nerve head (ONH). Subsequently, two different appr… ▽ More

    Submitted 8 November, 2021; v1 submitted 7 November, 2021; originally announced November 2021.

  2. arXiv:2012.09755  [pdf, other

    eess.IV cs.CV cs.LG

    Describing the Structural Phenotype of the Glaucomatous Optic Nerve Head Using Artificial Intelligence

    Authors: Satish K. Panda, Haris Cheong, Tin A. Tun, Sripad K. Devella, Ramaswami Krishnadas, Martin L. Buist, Shamira Perera, Ching-Yu Cheng, Tin Aung, Alexandre H. Thiéry, Michaël J. A. Girard

    Abstract: The optic nerve head (ONH) typically experiences complex neural- and connective-tissue structural changes with the development and progression of glaucoma, and monitoring these changes could be critical for improved diagnosis and prognosis in the glaucoma clinic. The gold-standard technique to assess structural changes of the ONH clinically is optical coherence tomography (OCT). However, OCT is li… ▽ More

    Submitted 17 December, 2020; originally announced December 2020.

  3. arXiv:2010.11698  [pdf, other

    eess.IV cs.CV

    OCT-GAN: Single Step Shadow and Noise Removal from Optical Coherence Tomography Images of the Human Optic Nerve Head

    Authors: Haris Cheong, Sripad Krishna Devalla, Thanadet Chuangsuwanich, Tin A. Tun, Xiaofei Wang, Tin Aung, Leopold Schmetterer, Martin L. Buist, Craig Boote, Alexandre H. Thiéry, Michaël J. A. Girard

    Abstract: Speckle noise and retinal shadows within OCT B-scans occlude important edges, fine textures and deep tissues, preventing accurate and robust diagnosis by algorithms and clinicians. We developed a single process that successfully removed both noise and retinal shadows from unseen single-frame B-scans within 10.4ms. Mean average gradient magnitude (AGM) for the proposed algorithm was 57.2% higher th… ▽ More

    Submitted 6 October, 2020; originally announced October 2020.

    Comments: 20 pages, 7 figures