Robust Sequential Steady-State Analysis of Cascading Outages
Authors:
Amritanshu Pandey,
Aayushya Agarwal,
Marko Jereminov,
Martin R. Wagner,
David M. Bromberg,
Larry Pileggi
Abstract:
Simulating potential cascading failures can be useful for avoiding or mitigating such events. Currently, existing steady-state analysis tools are ill-suited for simulating cascading outages as they do not model frequency dependencies, they require good initial conditions to converge, and they are unable to distinguish between a collapsed grid state from a hard-to-solve test case. In this paper, we…
▽ More
Simulating potential cascading failures can be useful for avoiding or mitigating such events. Currently, existing steady-state analysis tools are ill-suited for simulating cascading outages as they do not model frequency dependencies, they require good initial conditions to converge, and they are unable to distinguish between a collapsed grid state from a hard-to-solve test case. In this paper, we extend a circuit-theoretic approach for simulating the steady-state of a power grid to incorporate frequency deviations and implicit models for underfrequency and undervoltage load shedding. Using these models, we introduce a framework capable of robustly solving cascading outages of large-scale systems that can also locate infeasible regions. We demonstrate the efficacy of our approach by simulating entire cascading outages on more than 8000 nodes sample testcase.
△ Less
Submitted 21 November, 2019; v1 submitted 24 April, 2019;
originally announced April 2019.
-
Evaluating Feasibility within Power Flow
Authors:
Marko Jereminov,
David M. Bromberg,
Amritanshu Pandey,
Martin R. Wagner,
Larry Pileggi
Abstract:
Recent development of techniques that improve the convergence properties of power flow simulation have been demonstrated to facilitate scaling to large system sizes (80k+ buses). However, the problem remains to reliably identify cases that are infeasible, system configurations that have no solution. In this paper, we use the circuit theoretic approach based on adjoint networks to evaluate the feas…
▽ More
Recent development of techniques that improve the convergence properties of power flow simulation have been demonstrated to facilitate scaling to large system sizes (80k+ buses). However, the problem remains to reliably identify cases that are infeasible, system configurations that have no solution. In this paper, we use the circuit theoretic approach based on adjoint networks to evaluate the feasibility of a power flow test case and further locate and quantify the source of infeasibility in the cases operating beyond the tip of the nose curve. By creating infeasibility current source models that are added to each node of the system model and further coupling each source to its corresponding node of the adjoint network, any locations of insufficient real or reactive power are captured by a non-zero response of the adjoint network. Furthermore, it is shown that the proposed joint simulation of power flow and its adjoint network models provide the optimally minimized currents that can be later utilized to inform corrective actions to restore the feasibility of power flow problems.
△ Less
Submitted 7 December, 2019; v1 submitted 5 September, 2018;
originally announced September 2018.
-
Robust Power Flow and Three-Phase Power Flow Analyses
Authors:
Amritanshu Pandey,
Marko Jereminov,
Martin R. Wagner,
David M. Bromberg,
Gabriela Hug,
Larry Pileggi
Abstract:
Robust simulation is essential for reliable operation and planning of transmission and distribution power grids. At present, disparate methods exist for steady-state analysis of the transmission (power flow) and distribution power grid (three-phase power flow). Due to the non-linear nature of the problem, it is difficult for alternating current (AC) power flow and three-phase power flow analyses t…
▽ More
Robust simulation is essential for reliable operation and planning of transmission and distribution power grids. At present, disparate methods exist for steady-state analysis of the transmission (power flow) and distribution power grid (three-phase power flow). Due to the non-linear nature of the problem, it is difficult for alternating current (AC) power flow and three-phase power flow analyses to ensure convergence to the correct physical solution, particularly from arbitrary initial conditions, or when evaluating a change (e.g. contingency) in the grid. In this paper, we describe our equivalent circuit formulation approach with current and voltage variables that models both the positive sequence network of the transmission grid and three-phase network of the distribution grid without loss of generality. The proposed circuit models and formalism enable the extension and application of circuit simulation techniques to solve for the steady-state solution with excellent robustness of convergence. Examples for positive sequence transmission and three-phase distribution systems, including actual 75k+ nodes Eastern Interconnection transmission test cases and 8k+ nodes taxonomy distribution test cases, are solved from arbitrary initial guesses to demonstrate the efficacy of our approach.
△ Less
Submitted 8 August, 2018; v1 submitted 3 March, 2018;
originally announced March 2018.