State and parameter estimation for retinal laser treatment
Authors:
Viktoria Kleyman,
Manuel Schaller,
Mario Mordmuller,
Mitsuru Wilson,
Ralf Brinkmann,
Karl Worthmann,
Matthias A. Muller
Abstract:
Adequate therapeutic retinal laser irradiation needs to be adapted to the local absorption. This leads to time-consuming treatments as the laser power needs to be successively adjusted to avoid under- and overtreatment caused by too low or too high temperatures. Closed-loop control can overcome this burden by means of temperature measurements. To allow for model predictive control schemes, the cur…
▽ More
Adequate therapeutic retinal laser irradiation needs to be adapted to the local absorption. This leads to time-consuming treatments as the laser power needs to be successively adjusted to avoid under- and overtreatment caused by too low or too high temperatures. Closed-loop control can overcome this burden by means of temperature measurements. To allow for model predictive control schemes, the current state and the spot-dependent absorption need to be estimated. In this paper, we thoroughly compare moving horizon estimator (MHE) and extended Kalman filter (EKF) designs for joint state and parameter estimation. We consider two different scenarios, the estimation of one or two unknown absorption coefficients. For one unknown parameter, both estimators perform very similar. For two unknown parameters, we found that the MHE benefits from active parameter constraints at the beginning of the estimation, whereas after a settling time both estimators perform again very similar as long as the parameters are inside the considered parameter bounds.
△ Less
Submitted 23 March, 2022;
originally announced March 2022.
-
Parameter estimation and model reduction for retinal laser treatment
Authors:
Manuel Schaller,
Mitsuru Wilson,
Viktoria Kleyman,
Mario Mordmüller,
Ralf Brinkmann,
Matthias A. Müller,
Karl Worthmann
Abstract:
Laser photocoagulation is one of the most frequently used treatment approaches for retinal diseases such as diabetic retinopathy and macular edema. The use of model-based control, such as Model Predictive Control (MPC), enhances a safe and effective treatment by guaranteeing temperature bounds. In general, real-time requirements for model-based control designs are not met since the temperature dis…
▽ More
Laser photocoagulation is one of the most frequently used treatment approaches for retinal diseases such as diabetic retinopathy and macular edema. The use of model-based control, such as Model Predictive Control (MPC), enhances a safe and effective treatment by guaranteeing temperature bounds. In general, real-time requirements for model-based control designs are not met since the temperature distribution in the eye fundus is governed by a heat equation with a nonlinear parameter dependency. This issue is circumvented by representing the model by a lower-dimensional system which well-approximates the original model, including the parametric dependency. We combine a global-basis approach with the discrete empirical interpolation method, tailor its hyperparameters to laser photocoagulation, and show its superiority in comparison to a recently proposed method based on Taylor-series approximation. Its effectiveness is measured in computation time for MPC. We further present a case study to estimate the range of absorption parameters in porcine eyes, and by means of a theoretical and numerical sensitivity analysis we show that the sensitivity of the temperature increase is higher with respect to the absorption coefficient of the retinal pigment epithelium (RPE) than of the choroid's.
△ Less
Submitted 25 February, 2022;
originally announced February 2022.
-
Model predictive control for retinal laser treatment at 1 kHz
Authors:
Manuel Schaller,
Viktoria Kleyman,
Mario Mordmüller,
Christian Schmidt,
Mitsuru Wilson,
Ralf Brinkmann,
Matthias A. Müller,
Karl Worthmann
Abstract:
Laser photocoagulation is a technique applied in the treatment of retinal diseases. While this is often done manually or using simple control schemes, we pursue an optimization-based approach, namely Model Predictive Control (MPC), to enforce bounds on the peak temperature and, thus, safety during the medical treatment procedure - despite the spot-dependent absorption of the tissue. To this end, a…
▽ More
Laser photocoagulation is a technique applied in the treatment of retinal diseases. While this is often done manually or using simple control schemes, we pursue an optimization-based approach, namely Model Predictive Control (MPC), to enforce bounds on the peak temperature and, thus, safety during the medical treatment procedure - despite the spot-dependent absorption of the tissue. To this end, a repetition rate of 1 kHz is desirable rendering the real-time requirements a major challenge. We present a tailored MPC scheme using parametric model reduction, an extended Kalman filter for the parameter and state estimation, and suitably constructed stage costs and verify its applicability both in simulation and experiments with porcine eyes. Moreover, we give some insight on the implementation specifically tailored for fast numerical computations.
△ Less
Submitted 24 March, 2022; v1 submitted 25 February, 2022;
originally announced February 2022.
-
State and parameter estimation for model-based retinal laser treatment
Authors:
Viktoria Kleyman,
Manuel Schaller,
Mitsuru Wilson,
Mario Mordmüller,
Ralf Brinkmann,
Karl Worthmann,
Matthias A. Müller
Abstract:
We present an approach for state and parameter estimation in retinal laser treatment by a novel setup where both measurement and heating is performed by a single laser. In this medical application, the temperature that is induced by the laser in the patient's eye is critical for a successful and safe treatment. To this end, we pursue a model-based approach using a model given by a heat diffusion e…
▽ More
We present an approach for state and parameter estimation in retinal laser treatment by a novel setup where both measurement and heating is performed by a single laser. In this medical application, the temperature that is induced by the laser in the patient's eye is critical for a successful and safe treatment. To this end, we pursue a model-based approach using a model given by a heat diffusion equation on a cylindrical domain, where the source term is given by the absorbed laser power. The model is parametric in the sense that it involves an absorption coefficient, which depends on the treatment spot and plays a central role in the input-output behavior of the system. After discretization, we apply a particularly suited parametric model order reduction to ensure real-time tractability while retaining parameter dependence. We augment known state estimation techniques, i.e., extended Kalman filtering and moving horizon estimation, with parameter estimation to estimate the absorption coefficient and the current state of the system. Eventually, we show first results for simulated and experimental data from porcine eyes. We find that, regarding convergence speed, the moving horizon estimation slightly outperforms the extended Kalman filter on measurement data in terms of parameter and state estimation, however, on simulated data the results are very similar.
△ Less
Submitted 4 March, 2021;
originally announced March 2021.
-
Virtual H&E Histology by Fiber-Based Picosecond Two-Photon Microscopy
Authors:
Jan Philip Kolb,
Daniel Weng,
Hubertus Hakert,
Matthias Eibl,
Wolfgang Draxinger,
Tobias Meyer,
Thomas Gottschall,
Ralf Brinkmann,
Reginald Bringruber,
Jürgen Popp,
Jens Limpert,
Sebastian Nino Karpf,
Robert Huber
Abstract:
Two-Photon Microscopy (TPM) can provide three-dimensional morphological and functional contrast in vivo. Through proper staining, TPM can be utilized to create virtual, H&E equivalent images and thus can improve throughput in histology-based applications. We previously reported on a new light source for TPM that employs a compact and robust fiber-amplified, directly modulated laser. This laser is…
▽ More
Two-Photon Microscopy (TPM) can provide three-dimensional morphological and functional contrast in vivo. Through proper staining, TPM can be utilized to create virtual, H&E equivalent images and thus can improve throughput in histology-based applications. We previously reported on a new light source for TPM that employs a compact and robust fiber-amplified, directly modulated laser. This laser is pulse-to-pulse wavelength switchable between 1064 nm, 1122 nm, and 1186 nm with an adjustable pulse duration from 50ps to 5ns and arbitrary repetition rates up to 1MHz at kW-peak powers. Despite the longer pulse duration, it can achieve similar average signal levels compared to fs-setups by lowering the repetition rate to achieve similar cw and peak power levels. The longer pulses lead to a larger number of photons per pulse, which yields single shot fluorescence lifetime measurements (FLIM) by applying a fast 4 GSamples/s digitizer. In the previous setup, the wavelengths were limited to 1064 nm and longer. Here, we use four wave mixing in a non-linear photonic crystal fiber to expand the wavelength range down to 940 nm. This wavelength is highly suitable for imaging green fluorescent proteins in neurosciences and stains such as acridine orange (AO), eosin yellow (EY) and sulforhodamine 101 (SR101) used for histology applications. In a more compact setup, we also show virtual H&E histological imaging using a direct 1030 nm fiber MOPA.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.