-
Hyperpixels: Pixel Filter Arrays of Multivariate Optical Elements for Optimized Spectral Imaging
Authors:
Calum Williams,
Richard Cousins,
Christopher J. Mellor,
Sarah E. Bohndiek,
George S. D. Gordon
Abstract:
We introduce the concept of `hyperpixels' in which each element of a pixel filter array (suitable for CMOS image sensor integration) has a spectral transmission tailored to a target spectral component expected in application-specific scenes. These are analogous to arrays of multivariate optical elements that could be used for sensing specific analytes. Spectral tailoring is achieved by engineering…
▽ More
We introduce the concept of `hyperpixels' in which each element of a pixel filter array (suitable for CMOS image sensor integration) has a spectral transmission tailored to a target spectral component expected in application-specific scenes. These are analogous to arrays of multivariate optical elements that could be used for sensing specific analytes. Spectral tailoring is achieved by engineering the heights of multiple sub-pixel Fabry-Perot resonators that cover each pixel area. We first present a design approach for hyperpixels, based on a matched filter concept and, as an exemplar, design a set of 4 hyperpixels tailored to optimally discriminate between 4 spectral reflectance targets. Next, we fabricate repeating 2x2 pixel filter arrays of these designs, alongside repeating 2x2 arrays of an optimal bandpass filters, perform both spectral and imaging characterization. Experimentally measured hyperpixel transmission spectra show a 2.4x reduction in unmixing matrix condition number (p=0.031) compared to the optimal band-pass set. Imaging experiments using the filter arrays with a monochrome sensor achieve a 3.47x reduction in unmixing matrix condition number (p=0.020) compared to the optimal band-pass set. This demonstrates the utility of the hyperpixel approach and shows its superiority even over the optimal bandpass case. We expect that with further improvements in design and fabrication processes increased performance may be obtained. Because the hyperpixels are straightforward to customize, fabricate and can be placed atop monochrome sensors, this approach is highly versatile and could be adapted to a wide range of real-time imaging applications which are limited by low SNR including micro-endoscopy, capsule endoscopy, industrial inspection and machine vision.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
Targeted Multispectral Filter Array Design for Endoscopic Cancer Detection in the Gastrointestinal Tract
Authors:
Michaela Taylor-Williams,
Ran Tao,
Travis W Sawyer,
Dale J Waterhouse,
Jonghee Yoon,
Sarah E Bohndiek
Abstract:
Colour differences between healthy and diseased tissue in the gastrointestinal tract are detected visually by clinicians during white light endoscopy (WLE); however, the earliest signs of disease are often just a slightly different shade of pink compared to healthy tissue. Here, we propose to target alternative colours for imaging to improve contrast using custom multispectral filter arrays (MSFAs…
▽ More
Colour differences between healthy and diseased tissue in the gastrointestinal tract are detected visually by clinicians during white light endoscopy (WLE); however, the earliest signs of disease are often just a slightly different shade of pink compared to healthy tissue. Here, we propose to target alternative colours for imaging to improve contrast using custom multispectral filter arrays (MSFAs) that could be deployed in an endoscopic chip-on-tip configuration. Using an open-source toolbox, Opti-MSFA, we examined the optimal design of MSFAs for early cancer detection in the gastrointestinal tract. The toolbox was first extended to use additional classification models (k-Nearest Neighbour, Support Vector Machine, and Spectral Angle Mapper). Using input spectral data from published clinical trials examining the oesophagus and colon, we optimised the design of MSFAs with 3 to 9 different bands. We examined the variation of the spectral and spatial classification accuracy as a function of number of bands. The MSFA designs have high classification accuracies, suggesting that future implementation in endoscopy hardware could potentially enable improved early detection of disease in the gastrointestinal tract during routine screening and surveillance. Optimal MSFA configurations can achieve similar classification accuracies as the full spectral data in an implementation that could be realised in far simpler hardware. The reduced number of spectral bands could enable future deployment of multispectral imaging in an endoscopic chip-on-tip configuration.
△ Less
Submitted 15 August, 2023;
originally announced August 2023.
-
Moving beyond simulation: data-driven quantitative photoacoustic imaging using tissue-mimicking phantoms
Authors:
Janek Gröhl,
Thomas R. Else,
Lina Hacker,
Ellie V. Bunce,
Paul W. Sweeney,
Sarah E. Bohndiek
Abstract:
Accurate measurement of optical absorption coefficients from photoacoustic imaging (PAI) data would enable direct map** of molecular concentrations, providing vital clinical insight. The ill-posed nature of the problem of absorption coefficient recovery has prohibited PAI from achieving this goal in living systems due to the domain gap between simulation and experiment. To bridge this gap, we in…
▽ More
Accurate measurement of optical absorption coefficients from photoacoustic imaging (PAI) data would enable direct map** of molecular concentrations, providing vital clinical insight. The ill-posed nature of the problem of absorption coefficient recovery has prohibited PAI from achieving this goal in living systems due to the domain gap between simulation and experiment. To bridge this gap, we introduce a collection of experimentally well-characterised imaging phantoms and their digital twins. This first-of-a-kind phantom data set enables supervised training of a U-Net on experimental data for pixel-wise estimation of absorption coefficients. We show that training on simulated data results in artefacts and biases in the estimates, reinforcing the existence of a domain gap between simulation and experiment. Training on experimentally acquired data, however, yielded more accurate and robust estimates of optical absorption coefficients. We compare the results to fluence correction with a Monte Carlo model from reference optical properties of the materials, which yields a quantification error of approximately 20%. Application of the trained U-Nets to a blood flow phantom demonstrated spectral biases when training on simulated data, while application to a mouse model highlighted the ability of both learning-based approaches to recover the depth-dependent loss of signal intensity. We demonstrate that training on experimental phantoms can restore the correlation of signal amplitudes measured in depth. While the absolute quantification error remains high and further improvements are needed, our results highlight the promise of deep learning to advance quantitative PAI.
△ Less
Submitted 11 June, 2023;
originally announced June 2023.
-
Characterising optical fibre transmission matrices using metasurface reflector stacks for lensless imaging without distal access
Authors:
George S. D. Gordon,
Milana Gataric,
Alberto Gil C. P. Ramos,
Ralf Mouthaan,
Calum Williams,
Jonghee Yoon,
Timothy D. Wilkinson,
Sarah E. Bohndiek
Abstract:
The ability to form images through hair-thin optical fibres promises to open up new applications from biomedical imaging to industrial inspection. Unfortunately, deployment has been limited because small changes in mechanical deformation (e.g. bending) and temperature can completely scramble optical information, distorting images. Since such changes are dynamic, correcting them requires measuremen…
▽ More
The ability to form images through hair-thin optical fibres promises to open up new applications from biomedical imaging to industrial inspection. Unfortunately, deployment has been limited because small changes in mechanical deformation (e.g. bending) and temperature can completely scramble optical information, distorting images. Since such changes are dynamic, correcting them requires measurement of the fibre transmission matrix (TM) in situ immediately before imaging. TM calibration typically requires access to both the proximal and distal facets of the fibre simultaneously, which is not feasible during most realistic usage scenarios without compromising the thin form factor with bulky distal optics. Here, we introduce a new approach to determine the TM of multi-mode fibre (MMF) or multi-core fibre (MCF) in a reflection-mode configuration without access to the distal facet. A thin stack of structured metasurface reflectors is used at the distal facet to introduce wavelength-dependent, spatially heterogeneous reflectance profiles. We derive a first-order fibre model that compensates these wavelength-dependent changes in the TM and show that, consequently, the reflected data at 3 wavelengths can be used to unambiguously reconstruct the full TM by an iterative optimisation algorithm. We then present a method for sample illumination and imaging following TM reconstruction. Unlike previous approaches, our method does not require the TM to be unitary making it applicable to physically realistic fibre systems. We demonstrate TM reconstruction and imaging first using simulated non-unitary fibres and noisy reflection matrices, then using much larger experimentally-measured TMs of a densely-packed MCF, and finally on an experimentally-measured multi-wavelength set of TMs recorded from a MMF. Our findings pave the way for online transmission matrix calibration in situ in hair-thin optical fibres
△ Less
Submitted 5 April, 2019; v1 submitted 4 April, 2019;
originally announced April 2019.
-
Reconstruction of optical vector-fields with applications in endoscopic imaging
Authors:
Milana Gataric,
George S. D. Gordon,
Francesco Renna,
Alberto Gil C. P. Ramos,
Maria P. Alcolea,
Sarah E. Bohndiek
Abstract:
We introduce a framework for the reconstruction of the amplitude, phase and polarisation of an optical vector-field using calibration measurements acquired by an imaging device with an unknown linear transformation. By incorporating effective regularisation terms, this new approach is able to recover an optical vector-field with respect to an arbitrary representation system, which may be different…
▽ More
We introduce a framework for the reconstruction of the amplitude, phase and polarisation of an optical vector-field using calibration measurements acquired by an imaging device with an unknown linear transformation. By incorporating effective regularisation terms, this new approach is able to recover an optical vector-field with respect to an arbitrary representation system, which may be different from the one used in calibration. In particular, it enables the recovery of an optical vector-field with respect to a Fourier basis, which is shown to yield indicative features of increased scattering associated with tissue abnormalities. We demonstrate the effectiveness of our approach using synthetic holographic images as well as biological tissue samples in an experimental setting where measurements of an optical vector-field are acquired by a fibre endoscope, and observe that indeed the recovered Fourier coefficients are useful in distinguishing healthy tissues from lesions in early stages of oesophageal cancer.
△ Less
Submitted 18 July, 2018; v1 submitted 27 April, 2018;
originally announced April 2018.