-
Motion and temporal B0 shift corrections for quantitative susceptibility map** (QSM) and R2* map** using dual-echo spiral navigators and conjugate-phase reconstruction
Authors:
Yuguang Meng,
Jason W. Allen,
Vahid Khalilzad Sharghi,
Deqiang Qiu
Abstract:
Purpose: To develop an efficient navigator-based motion and temporal B0 shift correction technique for 3D multi-echo gradient-echo (ME-GRE) MRI for quantitative susceptibility map** (QSM) and R2* map**. Theory and Methods: A dual-echo 3D spiral navigator was designed to interleave with the Cartesian ME-GRE acquisitions, allowing the acquisition of both low- and high-echo time signals. We addit…
▽ More
Purpose: To develop an efficient navigator-based motion and temporal B0 shift correction technique for 3D multi-echo gradient-echo (ME-GRE) MRI for quantitative susceptibility map** (QSM) and R2* map**. Theory and Methods: A dual-echo 3D spiral navigator was designed to interleave with the Cartesian ME-GRE acquisitions, allowing the acquisition of both low- and high-echo time signals. We additionally designed a novel conjugate-phase based reconstruction method for the joint correction of motion and temporal B0 shifts. We performed both numerical simulation and in vivo human scans to assess the performance of the methods. Results: Numerical simulation and human brain scans demonstrated that the proposed technique successfully corrected artifacts induced by both head motions and temporal B0 changes. Efficient B0-change correction with conjugate-phase reconstruction can be performed on less than 10 clustered k-space segments. In vivo scans showed that combining temporal B0 correction with motion correction further reduced artifacts and improved image quality in both R2* and QSM images. Conclusion: Our proposed approach of using 3D spiral navigators and a novel conjugate-phase reconstruction method can improve susceptibility-related measurements using MR.
△ Less
Submitted 18 March, 2024;
originally announced March 2024.
-
Model-based T1, T2* and Proton Density Map** Using a Bayesian Approach with Parameter Estimation and Complementary Undersampling Patterns
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Purpose: To achieve automatic hyperparameter estimation for the joint recovery of quantitative MR images, we propose a Bayesian formulation of the reconstruction problem that incorporates the signal model. Additionally, we investigate the use of complementary undersampling patterns to determine optimal undersampling schemes for quantitative MRI.
Theory: We introduce a novel nonlinear approximate…
▽ More
Purpose: To achieve automatic hyperparameter estimation for the joint recovery of quantitative MR images, we propose a Bayesian formulation of the reconstruction problem that incorporates the signal model. Additionally, we investigate the use of complementary undersampling patterns to determine optimal undersampling schemes for quantitative MRI.
Theory: We introduce a novel nonlinear approximate message passing framework, referred to as ``AMP-PE'', that enables the simultaneous recovery of distribution parameters and quantitative maps.
Methods: We employed the variable flip angle multi-echo (VFA-ME) method to acquire measurements. Both retrospective and prospective undersampling approaches were utilized to obtain Fourier measurements using variable-density and Poisson-disk patterns. Furthermore, we extensively explored various undersampling schemes, incorporating complementary patterns across different flip angles and/or echo times.
Results: AMP-PE adopts a model-based joint recovery strategy, it outperforms the $l_1$-norm minimization approach that follows a decoupled recovery strategy. A comparison with an existing joint-recovery approach further demonstrates the advantageous outcomes of AMP-PE. For quantitative $T_1$ map** using VFA-ME, employing identical k-space sampling patterns across different echo times produced the best performance. Whereas for $T_2^*$ and proton density map**s, using complementary sampling patterns across different flip angles yielded the best performance.
Conclusion: AMP-PE is equipped with built-in parameter estimation, and works naturally in clinical settings with varying acquisition protocols and scanners. It also achieves improved performance by combining information from the MR signal model and the sparse prior on images.
△ Less
Submitted 10 September, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Robust Quantitative Susceptibility Map** via Approximate Message Passing with Parameter Estimation
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Purpose: For quantitative susceptibility map** (QSM), the lack of ground-truth in clinical settings makes it challenging to determine suitable parameters for the dipole inversion. We propose a probabilistic Bayesian approach for QSM with built-in parameter estimation, and incorporate the nonlinear formulation of the dipole inversion to achieve a robust recovery of the susceptibility maps.
Theo…
▽ More
Purpose: For quantitative susceptibility map** (QSM), the lack of ground-truth in clinical settings makes it challenging to determine suitable parameters for the dipole inversion. We propose a probabilistic Bayesian approach for QSM with built-in parameter estimation, and incorporate the nonlinear formulation of the dipole inversion to achieve a robust recovery of the susceptibility maps.
Theory: From a Bayesian perspective, the image wavelet coefficients are approximately sparse and modelled by the Laplace distribution. The measurement noise is modelled by a Gaussian-mixture distribution with two components, where the second component is used to model the noise outliers. Through probabilistic inference, the susceptibility map and distribution parameters can be jointly recovered using approximate message passing (AMP).
Methods: We compare our proposed AMP with built-in parameter estimation (AMP-PE) to the state-of-the-art L1-QSM, FANSI and MEDI approaches on the simulated and in vivo datasets, and perform experiments to explore the optimal settings of AMP-PE. Reproducible code is available at https://github.com/EmoryCN2L/QSM_AMP_PE
Results: On the simulated Sim2Snr1 dataset, AMP-PE achieved the lowest NRMSE, DFCM and the highest SSIM, while MEDI achieved the lowest HFEN. On the in vivo datasets, AMP-PE is robust and successfully recovers the susceptibility maps using the estimated parameters, whereas L1-QSM, FANSI and MEDI typically require additional visual fine-tuning to select or double-check working parameters.
Conclusion: AMP-PE provides automatic and adaptive parameter estimation for QSM and avoids the subjectivity from the visual fine-tuning step, making it an excellent choice for the clinical setting.
△ Less
Submitted 30 May, 2023; v1 submitted 29 July, 2022;
originally announced July 2022.
-
A method for virtual optical sectioning and tomography utilizing shallow depth of field
Authors:
T. E. Gureyev,
H. M. Quiney,
L. J. Allen
Abstract:
A method is proposed for high-resolution, three-dimensional reconstruction of internal structure of objects from planar transmission images. The described approach can be used with any form of radiation or matter waves, in principle, provided that the depth of field is smaller than the thickness of the sample. The physical optics basis for the method is elucidated and the reconstruction algorithm…
▽ More
A method is proposed for high-resolution, three-dimensional reconstruction of internal structure of objects from planar transmission images. The described approach can be used with any form of radiation or matter waves, in principle, provided that the depth of field is smaller than the thickness of the sample. The physical optics basis for the method is elucidated and the reconstruction algorithm is presented in detail. A simulated example demonstrates an application of the method to three-dimensional electron transmission imaging of a nanoparticle under realistic radiation dose and spatial resolution constraints. It is envisaged that the method can be applicable in high-resolution transmission electron microscopy, soft X-ray microscopy, ultrasound imaging and other areas.
△ Less
Submitted 3 April, 2022; v1 submitted 5 February, 2022;
originally announced February 2022.
-
A Probabilistic Bayesian Approach to Recover $R_2^*$ map and Phase Images for Quantitative Susceptibility Map**
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Purpose: Undersampling is used to reduce the scan time for high-resolution 3D magnetic resonance imaging. In order to achieve better image quality and avoid manual parameter tuning, we propose a probabilistic Bayesian approach to recover $R_2^*$ map and phase images for quantitative susceptibility map** (QSM), while allowing automatic parameter estimation from undersampled data.
Theory: Sparse…
▽ More
Purpose: Undersampling is used to reduce the scan time for high-resolution 3D magnetic resonance imaging. In order to achieve better image quality and avoid manual parameter tuning, we propose a probabilistic Bayesian approach to recover $R_2^*$ map and phase images for quantitative susceptibility map** (QSM), while allowing automatic parameter estimation from undersampled data.
Theory: Sparse prior on the wavelet coefficients of images is interpreted from a Bayesian perspective as sparsity-promoting distribution. A novel nonlinear approximate message passing (AMP) framework that incorporates a mono-exponential decay model is proposed. The parameters are treated as unknown variables and jointly estimated with image wavelet coefficients.
Results: The proposed AMP with parameter estimation (AMP-PE) approach successfully recovers $R_2^*$ maps and phase images for QSM across various undersampling rates. It is more computationally efficient, and performs better than the state-of-the-art $l_1$-norm regularization (L1) approach in general, except a few cases where the L1 approach performs as well as AMP-PE.
Conclusion: AMP-PE achieves better performance by drawing information from both the sparse prior and the mono-exponential decay model. It does not require parameter tuning, and works with a clinical, prospective undersampling scheme where parameter tuning is often impossible or difficult due to the lack of ground-truth image.
△ Less
Submitted 9 July, 2022; v1 submitted 9 March, 2021;
originally announced March 2021.
-
Power Off! Challenges in Planning and Executing Power Isolations on Shared-Use Electrified Railways
Authors:
Alex Lu,
Aleksandr Lukatskiy,
Zhiqi Zhong,
John G. Allen
Abstract:
Electric railways are fast, clean, and safe, but complex to operate and maintain. Electric traction infrastructure includes signal power and feeder lines that remain live during isolations and complicate maintenance processes. Stakeholders involved in power outage planning include contractors, linemen, groundmen, power directors, dispatchers, conductor-flag, and support personnel. Weekly planning…
▽ More
Electric railways are fast, clean, and safe, but complex to operate and maintain. Electric traction infrastructure includes signal power and feeder lines that remain live during isolations and complicate maintenance processes. Stakeholders involved in power outage planning include contractors, linemen, groundmen, power directors, dispatchers, conductor-flag, and support personnel. Weekly planning processes for track time requires many contingencies due to large number of moving parts and factors not known in advance, like personnel availability. Electrical and mechanical environments faced by crews working in adjacent areas may be entirely different and require a "bespoke" circuit configuration to de-energize catenary, which must be planned meticulously. Although recent automation improved real-time "plate order" communications between power directors and dispatchers, each outage still requires many manual switching operations. Net impact of this isolation process reduces available construction work windows nightly from a nominal 7 hours to 2 hrs 39 mins. We recommend joint design of electrical and civil infrastructure, cross-training between disciplines, limiting maximum number of concurrent outages, formal study of maintenance outage capacity, and further automation in power switching.
△ Less
Submitted 8 February, 2021;
originally announced February 2021.
-
Fast Nonconvex $T_2^*$ Map** Using ADMM
Authors:
Shuai Huang,
James J. Lah,
Jason W. Allen,
Deqiang Qiu
Abstract:
Magnetic resonance (MR)-$T_2^*$ map** is widely used to study hemorrhage, calcification and iron deposition in various clinical applications, it provides a direct and precise map** of desired contrast in the tissue. However, the long acquisition time required by conventional 3D high-resolution $T_2^*$ map** method causes discomfort to patients and introduces motion artifacts to reconstructed…
▽ More
Magnetic resonance (MR)-$T_2^*$ map** is widely used to study hemorrhage, calcification and iron deposition in various clinical applications, it provides a direct and precise map** of desired contrast in the tissue. However, the long acquisition time required by conventional 3D high-resolution $T_2^*$ map** method causes discomfort to patients and introduces motion artifacts to reconstructed images, which limits its wider applicability. In this paper we address this issue by performing $T_2^*$ map** from undersampled data using compressive sensing (CS). We formulate the reconstruction as a nonconvex problem that can be decomposed into two subproblems. They can be solved either separately via the standard approach or jointly via the alternating direction method of multipliers (ADMM). Compared to previous CS-based approaches that only apply sparse regularization on the spin density $\boldsymbol X_0$ and the relaxation rate $\boldsymbol R_2^*$, our formulation enforces additional sparse priors on the $T_2^*$-weighted images at multiple echoes to improve the reconstruction performance. We performed convergence analysis of the proposed algorithm, evaluated its performance on in vivo data, and studied the effects of different sampling schemes. Experimental results showed that the proposed joint-recovery approach generally outperforms the state-of-the-art method, especially in the low-sampling rate regime, making it a preferred choice to perform fast 3D $T_2^*$ map** in practice. The framework adopted in this work can be easily extended to other problems arising from MR or other imaging modalities with non-linearly coupled variables.
△ Less
Submitted 4 August, 2020;
originally announced August 2020.
-
SAGE: Sequential Attribute Generator for Analyzing Glioblastomas using Limited Dataset
Authors:
Padmaja Jonnalagedda,
Brent Weinberg,
Jason Allen,
Tae** L. Min,
Shiv Bhanu,
Bir Bhanu
Abstract:
While deep learning approaches have shown remarkable performance in many imaging tasks, most of these methods rely on availability of large quantities of data. Medical image data, however, is scarce and fragmented. Generative Adversarial Networks (GANs) have recently been very effective in handling such datasets by generating more data. If the datasets are very small, however, GANs cannot learn th…
▽ More
While deep learning approaches have shown remarkable performance in many imaging tasks, most of these methods rely on availability of large quantities of data. Medical image data, however, is scarce and fragmented. Generative Adversarial Networks (GANs) have recently been very effective in handling such datasets by generating more data. If the datasets are very small, however, GANs cannot learn the data distribution properly, resulting in less diverse or low-quality results. One such limited dataset is that for the concurrent gain of 19 and 20 chromosomes (19/20 co-gain), a mutation with positive prognostic value in Glioblastomas (GBM). In this paper, we detect imaging biomarkers for the mutation to streamline the extensive and invasive prognosis pipeline. Since this mutation is relatively rare, i.e. small dataset, we propose a novel generative framework - the Sequential Attribute GEnerator (SAGE), that generates detailed tumor imaging features while learning from a limited dataset. Experiments show that not only does SAGE generate high quality tumors when compared to standard Deep Convolutional GAN (DC-GAN) and Wasserstein GAN with Gradient Penalty (WGAN-GP), it also captures the imaging biomarkers accurately.
△ Less
Submitted 3 June, 2022; v1 submitted 14 May, 2020;
originally announced May 2020.
-
On electron imaging of small molecules, Part I: relative roles of multiple scattering and Fresnel diffraction
Authors:
T. E. Gureyev,
H. M. Quiney,
A. Kozlov,
L. J. Allen
Abstract:
The relative roles of multiple electron scattering and in-molecule free-space propagation in transmission electron microscopy of small molecules are discussed. It is argued that while multiple scattering tends to have only a moderate effect in this case, the in-molecule Fresnel diffraction is likely to be significant due to the shallow depth of focus under the relevant experimental conditions. As…
▽ More
The relative roles of multiple electron scattering and in-molecule free-space propagation in transmission electron microscopy of small molecules are discussed. It is argued that while multiple scattering tends to have only a moderate effect in this case, the in-molecule Fresnel diffraction is likely to be significant due to the shallow depth of focus under the relevant experimental conditions. As a consequence, diffraction tomography based on the first Born or first Rytov approximation represents a more suitable method for the reconstruction of three-dimensional distribution of the electrostatic potential in this context, compared to conventional computed tomography which is intrinsically based on the projection approximation. A simplified method for diffraction tomography is proposed and tested on numerically simulated examples.
△ Less
Submitted 27 November, 2019; v1 submitted 25 November, 2019;
originally announced November 2019.
-
On electron imaging of small molecules, Part II: tomographic reconstruction from defocus series
Authors:
T. E. Gureyev,
H. M. Quiney,
A. Kozlov,
L. J. Allen
Abstract:
A practical method utilising three-dimensional image pattern matching is proposed which, in principle, is capable of unambiguous determination of the types and positions of atoms in small molecules from defocus series collected at only a few different angular orientations of the molecule. Numerical tests of the method are presented using multislice calculations of defocus series of small biologica…
▽ More
A practical method utilising three-dimensional image pattern matching is proposed which, in principle, is capable of unambiguous determination of the types and positions of atoms in small molecules from defocus series collected at only a few different angular orientations of the molecule. Numerical tests of the method are presented using multislice calculations of defocus series of small biological molecules. The proposed technique can in future gain from Bayesian or machine-learning approaches and is likely to be useful in cryogenic electron microscopy.
△ Less
Submitted 27 November, 2019; v1 submitted 25 November, 2019;
originally announced November 2019.