Miniature fluorescence sensor for quantitative detection of brain tumour
Authors:
Jean Pierre Ndabakuranye,
James Belcourt,
Deepak Sharma,
Cathal D. O'Connell,
Victor Mondal,
Sanjay K. Srivastava,
Alastair Stacey,
Sam Long,
Bobbi Fleiss,
Arman Ahnood
Abstract:
Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. T…
▽ More
Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its remote spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 x 1 mm2. As well as addressing losses associated with collecting and coupling fluorescence light in the current remote sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
A novel optical assay system for bilirubin concentration measurement in whole blood
Authors:
Jean Pierre Ndabakuranye,
Anushi E. Rajapaksa,
Genia Burchall,
Shiqiang Li,
Steven Prawer,
Arman Ahnood
Abstract:
As a biomarker for liver disease, bilirubin has been utilized in prognostic scoring systems for cirrhosis. While laboratory-based methods are used to determine bilirubin levels in clinical settings, they do not readily lend themselves to applications outside of hospitals. Consequently, bilirubin monitoring for cirrhotic patients is often performed only intermittently; thus, episodes requiring clin…
▽ More
As a biomarker for liver disease, bilirubin has been utilized in prognostic scoring systems for cirrhosis. While laboratory-based methods are used to determine bilirubin levels in clinical settings, they do not readily lend themselves to applications outside of hospitals. Consequently, bilirubin monitoring for cirrhotic patients is often performed only intermittently; thus, episodes requiring clinical interventions could be missed. This work investigates the feasibility of measuring bilirubin concentration in whole porcine blood samples using dual-wavelength transmission measurement. A compact and low-cost dual-wavelength transmission measurement setup is developed and optimized to measure whole blood bilirubin concentrations. Using small volumes of whole porcine blood (72 μL), we measured the bilirubin concentration within a range corresponding to healthy individuals and cirrhotic patients (1.2-30 mg/dL). We demonstrate that bilirubin levels can be estimated with a positive correlation (R-square > 0.95) and an accuracy of +/- 1.7 mg/dL, with higher reliability in cirrhotic bilirubin concentrations (> 4 mg/dL), critical for high-risk patients. The optical and electronic components utilized are economical and can be readily integrated into a miniature, low-cost, and user-friendly system. This could provide a pathway for point-of-care monitoring of blood bilirubin outside of medical facilities.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
A leadless power transfer and wireless telemetry solutions for an endovascular electrocorticography
Authors:
Zhangyu Xu,
Majid Khazaee,
Nhan Duy Truong,
Deniel Havenga,
Armin Nikpour,
Arman Ahnood,
Omid Kavehei
Abstract:
Endovascular brain-computer interfaces (eBCIs) offer a minimally invasive way to connect the brain to external devices, merging neuroscience, engineering, and medical technology. Achieving wireless data and power transmission is crucial for the clinical viability of these implantable devices. Typically, solutions for endovascular electrocorticography (ECoG) include a sensing stent with multiple el…
▽ More
Endovascular brain-computer interfaces (eBCIs) offer a minimally invasive way to connect the brain to external devices, merging neuroscience, engineering, and medical technology. Achieving wireless data and power transmission is crucial for the clinical viability of these implantable devices. Typically, solutions for endovascular electrocorticography (ECoG) include a sensing stent with multiple electrodes (e.g. in the superior sagittal sinus) in the brain, a subcutaneous chest implant for wireless energy harvesting and data telemetry, and a long (tens of centimetres) cable with a set of wires in between. This long cable presents risks and limitations, especially for younger patients or those with fragile vasculature. This work introduces a wireless and leadless telemetry and power transfer solution for endovascular ECoG. The proposed solution includes an optical telemetry module and a focused ultrasound (FUS) power transfer system. The proposed system can be miniaturised to fit in an endovascular stent. Our solution uses optical telemetry for high-speed data transmission (over 2 Mbit/s, capable of transmitting 41 ECoG channels at a 2 kHz sampling rate and 24-bit resolution) and the proposed power transferring scheme provides up to 10mW power budget into the site of the endovascular implants under the safety limit. Tests on bovine tissues confirmed the system's effectiveness, suggesting that future custom circuit designs could further enhance eBCI applications by removing wires and auxiliary implants, minimising complications.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.
-
A Single Sensor Based Multispectral Imaging Camera using a Narrow Spectral Band Colour Mosaic Integrated on the Monochrome CMOS Image Sensor
Authors:
Xin He,
Ya**g Liu,
Kumar Ganesan,
Arman Ahnood,
Paul Beckett,
Fatima Eftekhari,
Dan Smith,
MD Hemayet Uddin,
Efstratios Skafidas,
Ampalavanapillai Nirmalathas,
Ranjith Rajasekharan Unnithan
Abstract:
A multispectral image camera captures image data within specific wavelength ranges in narrow wavelength bands across the electromagnetic spectrum. Images from a multispectral camera can extract additional information that the human eye or a normal camera fails to capture and thus may have important applications in precision agriculture, forestry, medicine and object identification. Conventional mu…
▽ More
A multispectral image camera captures image data within specific wavelength ranges in narrow wavelength bands across the electromagnetic spectrum. Images from a multispectral camera can extract additional information that the human eye or a normal camera fails to capture and thus may have important applications in precision agriculture, forestry, medicine and object identification. Conventional multispectral cameras are made up of multiple image sensors each fitted with a narrow passband wavelength filter and optics, which makes them heavy, bulky, power hungry and very expensive. The multiple optics also create image co-registration problem. Here, we demonstrate a single sensor based three band multispectral camera using a narrow spectral band RGB colour mosaic in a Bayer pattern integrated on a monochrome CMOS sensor. The narrow band colour mosaic is made of a hybrid combination of plasmonic colour filters and heterostructured dielectric multilayer. The demonstrated camera technology has reduced cost, weight, size and power by almost n times (where n is the number of bands) compared to a conventional multispectral camera.
△ Less
Submitted 2 December, 2020;
originally announced December 2020.
-
Feasibility Assessment of an Optically Powered Digital Retinal Prosthesis Architecture for Retinal Ganglion Cell Stimulation
Authors:
William Lemaire,
Maher Benhouria,
Konin Koua,
Wei Tong,
Gabriel Martin-Hardy,
Melanie Stamp,
Kumaravelu Ganesan,
Louis-Philippe Gauthier,
Marwan Besrour,
Arman Ahnood,
David John Garrett,
Sébastien Roy,
Michael Ibbotson,
Steven Prawer,
Réjean Fontaine
Abstract:
Clinical trials previously demonstrated the notable capacity to elicit visual percepts in blind patients affected with retinal diseases by electrically stimulating the remaining neurons on the retina. However, these implants restored very limited visual acuity and required transcutaneous cables traversing the eyeball, leading to reduced reliability and complex surgery with high postoperative infec…
▽ More
Clinical trials previously demonstrated the notable capacity to elicit visual percepts in blind patients affected with retinal diseases by electrically stimulating the remaining neurons on the retina. However, these implants restored very limited visual acuity and required transcutaneous cables traversing the eyeball, leading to reduced reliability and complex surgery with high postoperative infection risks. To overcome the limitations imposed by cables, a retinal implant architecture in which near-infrared illumination carries both power and data through the pupil to a digital stimulation controller is presented. A high efficiency multi-junction photovoltaic cell transduces the optical power to a CMOS stimulator capable of delivering flexible interleaved sequential stimulation through a diamond microelectrode array. To demonstrate the capacity to elicit a neural response with this approach while complying with the optical irradiance limit at the pupil, fluorescence imaging with a calcium indicator is used on a degenerate rat retina. The power delivered by the laser at the permissible irradiance of 4 mW/mm2 at 850 nm is shown to be sufficient to both power the stimulator ASIC and elicit a response in retinal ganglion cells (RGCs), with the ability to generate of up to 35 000 pulses per second at the average stimulation threshold. This confirms the feasibility of generating a response in RGCs with an infrared-powered digital architecture capable of delivering complex sequential stimulation patterns at high repetition rates, albeit with some limitations.
△ Less
Submitted 13 October, 2023; v1 submitted 23 October, 2020;
originally announced October 2020.