-
MedShapeNet -- A Large-Scale Dataset of 3D Medical Shapes for Computer Vision
Authors:
Jianning Li,
Zongwei Zhou,
Jiancheng Yang,
Antonio Pepe,
Christina Gsaxner,
Gijs Luijten,
Chongyu Qu,
Tiezheng Zhang,
Xiaoxi Chen,
Wenxuan Li,
Marek Wodzinski,
Paul Friedrich,
Kangxian Xie,
Yuan **,
Narmada Ambigapathy,
Enrico Nasca,
Naida Solak,
Gian Marco Melito,
Viet Duc Vu,
Afaque R. Memon,
Christopher Schlachta,
Sandrine De Ribaupierre,
Rajnikant Patel,
Roy Eagleson,
Xiaojun Chen
, et al. (132 additional authors not shown)
Abstract:
Prior to the deep learning era, shape was commonly used to describe the objects. Nowadays, state-of-the-art (SOTA) algorithms in medical imaging are predominantly diverging from computer vision, where voxel grids, meshes, point clouds, and implicit surface models are used. This is seen from numerous shape-related publications in premier vision conferences as well as the growing popularity of Shape…
▽ More
Prior to the deep learning era, shape was commonly used to describe the objects. Nowadays, state-of-the-art (SOTA) algorithms in medical imaging are predominantly diverging from computer vision, where voxel grids, meshes, point clouds, and implicit surface models are used. This is seen from numerous shape-related publications in premier vision conferences as well as the growing popularity of ShapeNet (about 51,300 models) and Princeton ModelNet (127,915 models). For the medical domain, we present a large collection of anatomical shapes (e.g., bones, organs, vessels) and 3D models of surgical instrument, called MedShapeNet, created to facilitate the translation of data-driven vision algorithms to medical applications and to adapt SOTA vision algorithms to medical problems. As a unique feature, we directly model the majority of shapes on the imaging data of real patients. As of today, MedShapeNet includes 23 dataset with more than 100,000 shapes that are paired with annotations (ground truth). Our data is freely accessible via a web interface and a Python application programming interface (API) and can be used for discriminative, reconstructive, and variational benchmarks as well as various applications in virtual, augmented, or mixed reality, and 3D printing. Exemplary, we present use cases in the fields of classification of brain tumors, facial and skull reconstructions, multi-class anatomy completion, education, and 3D printing. In future, we will extend the data and improve the interfaces. The project pages are: https://medshapenet.ikim.nrw/ and https://github.com/Jianningli/medshapenet-feedback
△ Less
Submitted 12 December, 2023; v1 submitted 30 August, 2023;
originally announced August 2023.
-
Preoperative Volume Determination for Pituitary Adenoma
Authors:
Dzenan Zukic,
Jan Egger,
Miriam H. A. Bauer,
Daniela Kuhnt,
Barbara Carl,
Bernd Freisleben,
Andreas Kolb,
Christopher Nimsky
Abstract:
The most common sellar lesion is the pituitary adenoma, and sellar tumors are approximately 10-15% of all intracranial neoplasms. Manual slice-by-slice segmentation takes quite some time that can be reduced by using the appropriate algorithms. In this contribution, we present a segmentation method for pituitary adenoma. The method is based on an algorithm that we have applied recently to segmentin…
▽ More
The most common sellar lesion is the pituitary adenoma, and sellar tumors are approximately 10-15% of all intracranial neoplasms. Manual slice-by-slice segmentation takes quite some time that can be reduced by using the appropriate algorithms. In this contribution, we present a segmentation method for pituitary adenoma. The method is based on an algorithm that we have applied recently to segmenting glioblastoma multiforme. A modification of this scheme is used for adenoma segmentation that is much harder to perform, due to lack of contrast-enhanced boundaries. In our experimental evaluation, neurosurgeons performed manual slice-by-slice segmentation of ten magnetic resonance imaging (MRI) cases. The segmentations were compared to the segmentation results of the proposed method using the Dice Similarity Coefficient (DSC). The average DSC for all datasets was 75.92% +/- 7.24%. A manual segmentation took about four minutes and our algorithm required about one second.
△ Less
Submitted 5 February, 2016;
originally announced February 2016.
-
SlicerPET: A workflow based software module for PET/CT guided needle biopsy
Authors:
Dženan Zukić,
Julien Finet,
Emmanuel Wilson,
Filip Banovac,
Giuseppe Esposito,
Kevin Cleary,
Andinet Enquobahrie
Abstract:
Biopsy is commonly used to confirm cancer diagnosis when radiologically indicated. Given the ability of PET to localize malignancies in heterogeneous tumors and tumors that do not have a CT correlate, PET/CT guided biopsy may improve the diagnostic yield of biopsies. To facilitate PET/CT guided needle biopsy, we developed a workflow that allows us to bring PET image guidance into the interventiona…
▽ More
Biopsy is commonly used to confirm cancer diagnosis when radiologically indicated. Given the ability of PET to localize malignancies in heterogeneous tumors and tumors that do not have a CT correlate, PET/CT guided biopsy may improve the diagnostic yield of biopsies. To facilitate PET/CT guided needle biopsy, we developed a workflow that allows us to bring PET image guidance into the interventional CT suite. In this abstract, we present SlicerPET, a user-friendly workflow based module developed using open source software libraries to guide needle biopsy in the interventional suite.
△ Less
Submitted 25 November, 2015;
originally announced November 2015.
-
Square-Cut: A Segmentation Algorithm on the Basis of a Rectangle Shape
Authors:
Jan Egger,
Tina Kapur,
Thomas Dukatz,
Malgorzata Kolodziej,
Dzenan Zukic,
Bernd Freisleben,
Christopher Nimsky
Abstract:
We present a rectangle-based segmentation algorithm that sets up a graph and performs a graph cut to separate an object from the background. However, graph-based algorithms distribute the graph's nodes uniformly and equidistantly on the image. Then, a smoothness term is added to force the cut to prefer a particular shape. This strategy does not allow the cut to prefer a certain structure, especial…
▽ More
We present a rectangle-based segmentation algorithm that sets up a graph and performs a graph cut to separate an object from the background. However, graph-based algorithms distribute the graph's nodes uniformly and equidistantly on the image. Then, a smoothness term is added to force the cut to prefer a particular shape. This strategy does not allow the cut to prefer a certain structure, especially when areas of the object are indistinguishable from the background. We solve this problem by referring to a rectangle shape of the object when sampling the graph nodes, i.e., the nodes are distributed nonuniformly and non-equidistantly on the image. This strategy can be useful, when areas of the object are indistinguishable from the background. For evaluation, we focus on vertebrae images from Magnetic Resonance Imaging (MRI) datasets to support the time consuming manual slice-by-slice segmentation performed by physicians. The ground truth of the vertebrae boundaries were manually extracted by two clinical experts (neurological surgeons) with several years of experience in spine surgery and afterwards compared with the automatic segmentation results of the proposed scheme yielding an average Dice Similarity Coefficient (DSC) of 90.97\pm62.2%.
△ Less
Submitted 13 March, 2012;
originally announced March 2012.
-
A Comparison of Two Human Brain Tumor Segmentation Methods for MRI Data
Authors:
Jan Egger,
Dženan Zukić,
Miriam H. A. Bauer,
Daniela Kuhnt,
Barbara Carl,
Bernd Freisleben,
Andreas Kolb,
Christopher Nimsky
Abstract:
The most common primary brain tumors are gliomas, evolving from the cerebral supportive cells. For clinical follow-up, the evaluation of the preoperative tumor volume is essential. Volumetric assessment of tumor volume with manual segmentation of its outlines is a time-consuming process that can be overcome with the help of computerized segmentation methods. In this contribution, two methods for W…
▽ More
The most common primary brain tumors are gliomas, evolving from the cerebral supportive cells. For clinical follow-up, the evaluation of the preoperative tumor volume is essential. Volumetric assessment of tumor volume with manual segmentation of its outlines is a time-consuming process that can be overcome with the help of computerized segmentation methods. In this contribution, two methods for World Health Organization (WHO) grade IV glioma segmentation in the human brain are compared using magnetic resonance imaging (MRI) patient data from the clinical routine. One method uses balloon inflation forces, and relies on detection of high intensity tumor boundaries that are coupled with the use of contrast agent gadolinium. The other method sets up a directed and weighted graph and performs a min-cut for optimal segmentation results. The ground truth of the tumor boundaries - for evaluating the methods on 27 cases - is manually extracted by neurosurgeons with several years of experience in the resection of gliomas. A comparison is performed using the Dice Similarity Coefficient (DSC), a measure for the spatial overlap of different segmentation results.
△ Less
Submitted 10 March, 2011; v1 submitted 9 February, 2011;
originally announced February 2011.
-
Glioblastoma Multiforme Segmentation in MRI Data with a Balloon Inflation Approach
Authors:
Dženan Zukić,
Jan Egger,
Miriam H. A. Bauer,
Daniela Kuhnt,
Barbara Carl,
Bernd Freisleben,
Andreas Kolb,
Christopher Nimsky
Abstract:
Gliomas are the most common primary brain tumors, evolving from the cerebral supportive cells. For clinical follow-up, the evaluation of the preoperative tumor volume is essential. Volumetric assessment of tumor volume with manual segmentation of its outlines is a time-consuming process that can be overcome with the help of computer-assisted segmentation methods. In this paper, a semi-automatic ap…
▽ More
Gliomas are the most common primary brain tumors, evolving from the cerebral supportive cells. For clinical follow-up, the evaluation of the preoperative tumor volume is essential. Volumetric assessment of tumor volume with manual segmentation of its outlines is a time-consuming process that can be overcome with the help of computer-assisted segmentation methods. In this paper, a semi-automatic approach for World Health Organization (WHO) grade IV glioma segmentation is introduced that uses balloon inflation forces, and relies on the detection of high-intensity tumor boundaries that are coupled by using contrast agent gadolinium. The presented method is evaluated on 27 magnetic resonance imaging (MRI) data sets and the ground truth data of the tumor boundaries - for evaluation of the results - are manually extracted by neurosurgeons.
△ Less
Submitted 3 February, 2011;
originally announced February 2011.
-
A Neural Network Classifier of Volume Datasets
Authors:
Dženan Zukić,
Christof Rezk-Salama,
Andreas Kolb
Abstract:
Many state-of-the art visualization techniques must be tailored to the specific type of dataset, its modality (CT, MRI, etc.), the recorded object or anatomical region (head, spine, abdomen, etc.) and other parameters related to the data acquisition process. While parts of the information (imaging modality and acquisition sequence) may be obtained from the meta-data stored with the volume scan,…
▽ More
Many state-of-the art visualization techniques must be tailored to the specific type of dataset, its modality (CT, MRI, etc.), the recorded object or anatomical region (head, spine, abdomen, etc.) and other parameters related to the data acquisition process. While parts of the information (imaging modality and acquisition sequence) may be obtained from the meta-data stored with the volume scan, there is important information which is not stored explicitly (anatomical region, tracing compound). Also, meta-data might be incomplete, inappropriate or simply missing.
This paper presents a novel and simple method of determining the type of dataset from previously defined categories. 2D histograms based on intensity and gradient magnitude of datasets are used as input to a neural network, which classifies it into one of several categories it was trained with. The proposed method is an important building block for visualization systems to be used autonomously by non-experts. The method has been tested on 80 datasets, divided into 3 classes and a "rest" class.
A significant result is the ability of the system to classify datasets into a specific class after being trained with only one dataset of that class. Other advantages of the method are its easy implementation and its high computational performance.
△ Less
Submitted 12 June, 2009;
originally announced June 2009.
-
Neural networks in 3D medical scan visualization
Authors:
Dženan Zukić,
Andreas Elsner,
Zikrija Avdagić,
Gitta Domik
Abstract:
For medical volume visualization, one of the most important tasks is to reveal clinically relevant details from the 3D scan (CT, MRI ...), e.g. the coronary arteries, without obscuring them with less significant parts. These volume datasets contain different materials which are difficult to extract and visualize with 1D transfer functions based solely on the attenuation coefficient. Multi-dimens…
▽ More
For medical volume visualization, one of the most important tasks is to reveal clinically relevant details from the 3D scan (CT, MRI ...), e.g. the coronary arteries, without obscuring them with less significant parts. These volume datasets contain different materials which are difficult to extract and visualize with 1D transfer functions based solely on the attenuation coefficient. Multi-dimensional transfer functions allow a much more precise classification of data which makes it easier to separate different surfaces from each other. Unfortunately, setting up multi-dimensional transfer functions can become a fairly complex task, generally accomplished by trial and error. This paper explains neural networks, and then presents an efficient way to speed up visualization process by semi-automatic transfer function generation. We describe how to use neural networks to detect distinctive features shown in the 2D histogram of the volume data and how to use this information for data classification.
△ Less
Submitted 12 June, 2009; v1 submitted 18 June, 2008;
originally announced June 2008.