-
Improving Human Motion Prediction Through Continual Learning
Authors:
Mohammad Samin Yasar,
Tariq Iqbal
Abstract:
Human motion prediction is an essential component for enabling closer human-robot collaboration. The task of accurately predicting human motion is non-trivial. It is compounded by the variability of human motion, both at a skeletal level due to the varying size of humans and at a motion level due to individual movement's idiosyncrasies. These variables make it challenging for learning algorithms t…
▽ More
Human motion prediction is an essential component for enabling closer human-robot collaboration. The task of accurately predicting human motion is non-trivial. It is compounded by the variability of human motion, both at a skeletal level due to the varying size of humans and at a motion level due to individual movement's idiosyncrasies. These variables make it challenging for learning algorithms to obtain a general representation that is robust to the diverse spatio-temporal patterns of human motion. In this work, we propose a modular sequence learning approach that allows end-to-end training while also having the flexibility of being fine-tuned. Our approach relies on the diversity of training samples to first learn a robust representation, which can then be fine-tuned in a continual learning setup to predict the motion of new subjects. We evaluated the proposed approach by comparing its performance against state-of-the-art baselines. The results suggest that our approach outperforms other methods over all the evaluated temporal horizons, using a small amount of data for fine-tuning. The improved performance of our approach opens up the possibility of using continual learning for personalized and reliable motion prediction.
△ Less
Submitted 1 July, 2021;
originally announced July 2021.
-
A Reactive Autonomous Camera System for the RAVEN II Surgical Robot
Authors:
Kay Hutchinson,
Mohammad Samin Yasar,
Harshneet Bhatia,
Homa Alemzadeh
Abstract:
The endoscopic camera of a surgical robot provides surgeons with a magnified 3D view of the surgical field, but repositioning it increases mental workload and operation time. Poor camera placement contributes to safety-critical events when surgical tools move out of the view of the camera. This paper presents a proof of concept of an autonomous camera system for the Raven II surgical robot that ai…
▽ More
The endoscopic camera of a surgical robot provides surgeons with a magnified 3D view of the surgical field, but repositioning it increases mental workload and operation time. Poor camera placement contributes to safety-critical events when surgical tools move out of the view of the camera. This paper presents a proof of concept of an autonomous camera system for the Raven II surgical robot that aims to reduce surgeon workload and improve safety by providing an optimal view of the workspace showing all objects of interest. This system uses transfer learning to localize and classify objects of interest within the view of a stereoscopic camera. The positions and centroid of the objects are estimated and a set of control rules determines the movement of the camera towards a more desired view. Our perception module had an accuracy of 61.21% overall for identifying objects of interest and was able to localize both graspers and multiple blocks in the environment. Comparison of the commands proposed by our system with the desired commands from a survey of 13 participants indicates that the autonomous camera system proposes appropriate movements for the tilt and pan of the camera.
△ Less
Submitted 9 October, 2020;
originally announced October 2020.
-
Real-Time Context-aware Detection of Unsafe Events in Robot-Assisted Surgery
Authors:
Mohammad Samin Yasar,
Homa Alemzadeh
Abstract:
Cyber-physical systems for robotic surgery have enabled minimally invasive procedures with increased precision and shorter hospitalization. However, with increasing complexity and connectivity of software and major involvement of human operators in the supervision of surgical robots, there remain significant challenges in ensuring patient safety. This paper presents a safety monitoring system that…
▽ More
Cyber-physical systems for robotic surgery have enabled minimally invasive procedures with increased precision and shorter hospitalization. However, with increasing complexity and connectivity of software and major involvement of human operators in the supervision of surgical robots, there remain significant challenges in ensuring patient safety. This paper presents a safety monitoring system that, given the knowledge of the surgical task being performed by the surgeon, can detect safety-critical events in real-time. Our approach integrates a surgical gesture classifier that infers the operational context from the time-series kinematics data of the robot with a library of erroneous gesture classifiers that given a surgical gesture can detect unsafe events. Our experiments using data from two surgical platforms show that the proposed system can detect unsafe events caused by accidental or malicious faults within an average reaction time window of 1,693 milliseconds and F1 score of 0.88 and human errors within an average reaction time window of 57 milliseconds and F1 score of 0.76.
△ Less
Submitted 18 June, 2020; v1 submitted 7 May, 2020;
originally announced May 2020.
-
Context-aware Monitoring in Robotic Surgery
Authors:
Mohammad Samin Yasar,
David Evans,
Homa Alemzadeh
Abstract:
Robotic-assisted minimally invasive surgery (MIS) has enabled procedures with increased precision and dexterity, but surgical robots are still open loop and require surgeons to work with a tele-operation console providing only limited visual feedback. In this setting, mechanical failures, software faults, or human errors might lead to adverse events resulting in patient complications or fatalities…
▽ More
Robotic-assisted minimally invasive surgery (MIS) has enabled procedures with increased precision and dexterity, but surgical robots are still open loop and require surgeons to work with a tele-operation console providing only limited visual feedback. In this setting, mechanical failures, software faults, or human errors might lead to adverse events resulting in patient complications or fatalities. We argue that impending adverse events could be detected and mitigated by applying context-specific safety constraints on the motions of the robot. We present a context-aware safety monitoring system which segments a surgical task into subtasks using kinematics data and monitors safety constraints specific to each subtask. To test our hypothesis about context specificity of safety constraints, we analyze recorded demonstrations of dry-lab surgical tasks collected from the JIGSAWS database as well as from experiments we conducted on a Raven II surgical robot. Analysis of the trajectory data shows that each subtask of a given surgical procedure has consistent safety constraints across multiple demonstrations by different subjects. Our preliminary results show that violations of these safety constraints lead to unsafe events, and there is often sufficient time between the constraint violation and the safety-critical event to allow for a corrective action.
△ Less
Submitted 28 January, 2019;
originally announced January 2019.