Artificial intelligence for abnormality detection in high volume neuroimaging: a systematic review and meta-analysis
Authors:
Siddharth Agarwal,
David A. Wood,
Mariusz Grzeda,
Chandhini Suresh,
Munaib Din,
James Cole,
Marc Modat,
Thomas C Booth
Abstract:
Purpose: Most studies evaluating artificial intelligence (AI) models that detect abnormalities in neuroimaging are either tested on unrepresentative patient cohorts or are insufficiently well-validated, leading to poor generalisability to real-world tasks. The aim was to determine the diagnostic test accuracy and summarise the evidence supporting the use of AI models performing first-line, high-vo…
▽ More
Purpose: Most studies evaluating artificial intelligence (AI) models that detect abnormalities in neuroimaging are either tested on unrepresentative patient cohorts or are insufficiently well-validated, leading to poor generalisability to real-world tasks. The aim was to determine the diagnostic test accuracy and summarise the evidence supporting the use of AI models performing first-line, high-volume neuroimaging tasks.
Methods: Medline, Embase, Cochrane library and Web of Science were searched until September 2021 for studies that temporally or externally validated AI capable of detecting abnormalities in first-line CT or MR neuroimaging. A bivariate random-effects model was used for meta-analysis where appropriate. PROSPERO: CRD42021269563.
Results: Only 16 studies were eligible for inclusion. Included studies were not compromised by unrepresentative datasets or inadequate validation methodology. Direct comparison with radiologists was available in 4/16 studies. 15/16 had a high risk of bias. Meta-analysis was only suitable for intracranial haemorrhage detection in CT imaging (10/16 studies), where AI systems had a pooled sensitivity and specificity 0.90 (95% CI 0.85 - 0.94) and 0.90 (95% CI 0.83 - 0.95) respectively. Other AI studies using CT and MRI detected target conditions other than haemorrhage (2/16), or multiple target conditions (4/16). Only 3/16 studies implemented AI in clinical pathways, either for pre-read triage or as post-read discrepancy identifiers.
Conclusion: The paucity of eligible studies reflects that most abnormality detection AI studies were not adequately validated in representative clinical cohorts. The few studies describing how abnormality detection AI could impact patients and clinicians did not explore the full ramifications of clinical implementation.
△ Less
Submitted 9 May, 2024;
originally announced May 2024.
-
A self-supervised text-vision framework for automated brain abnormality detection
Authors:
David A. Wood,
Emily Guilhem,
Sina Kafiabadi,
Ayisha Al Busaidi,
Kishan Dissanayake,
Ahmed Hammam,
Nina Mansoor,
Matthew Townend,
Siddharth Agarwal,
Yiran Wei,
Asif Mazumder,
Gareth J. Barker,
Peter Sasieni,
Sebastien Ourselin,
James H. Cole,
Thomas C. Booth
Abstract:
Artificial neural networks trained on large, expert-labelled datasets are considered state-of-the-art for a range of medical image recognition tasks. However, categorically labelled datasets are time-consuming to generate and constrain classification to a pre-defined, fixed set of classes. For neuroradiological applications in particular, this represents a barrier to clinical adoption. To address…
▽ More
Artificial neural networks trained on large, expert-labelled datasets are considered state-of-the-art for a range of medical image recognition tasks. However, categorically labelled datasets are time-consuming to generate and constrain classification to a pre-defined, fixed set of classes. For neuroradiological applications in particular, this represents a barrier to clinical adoption. To address these challenges, we present a self-supervised text-vision framework that learns to detect clinically relevant abnormalities in brain MRI scans by directly leveraging the rich information contained in accompanying free-text neuroradiology reports. Our training approach consisted of two-steps. First, a dedicated neuroradiological language model - NeuroBERT - was trained to generate fixed-dimensional vector representations of neuroradiology reports (N = 50,523) via domain-specific self-supervised learning tasks. Next, convolutional neural networks (one per MRI sequence) learnt to map individual brain scans to their corresponding text vector representations by optimising a mean square error loss. Once trained, our text-vision framework can be used to detect abnormalities in unreported brain MRI examinations by scoring scans against suitable query sentences (e.g., 'there is an acute stroke', 'there is hydrocephalus' etc.), enabling a range of classification-based applications including automated triage. Potentially, our framework could also serve as a clinical decision support tool, not only by suggesting findings to radiologists and detecting errors in provisional reports, but also by retrieving and displaying examples of pathologies from historical examinations that could be relevant to the current case based on textual descriptors.
△ Less
Submitted 11 June, 2024; v1 submitted 4 May, 2024;
originally announced May 2024.
-
NEURO HAND: A weakly supervised Hierarchical Attention Network for interpretable neuroimaging abnormality Detection
Authors:
David A. Wood
Abstract:
Clinical neuroimaging data is naturally hierarchical. Different magnetic resonance imaging (MRI) sequences within a series, different slices covering the head, and different regions within each slice all confer different information. In this work we present a hierarchical attention network for abnormality detection using MRI scans obtained in a clinical hospital setting. The proposed network is su…
▽ More
Clinical neuroimaging data is naturally hierarchical. Different magnetic resonance imaging (MRI) sequences within a series, different slices covering the head, and different regions within each slice all confer different information. In this work we present a hierarchical attention network for abnormality detection using MRI scans obtained in a clinical hospital setting. The proposed network is suitable for non-volumetric data (i.e. stacks of high-resolution MRI slices), and can be trained from binary examination-level labels. We show that this hierarchical approach leads to improved classification, while providing interpretability through either coarse inter- and intra-slice abnormality localisation, or giving importance scores for different slices and sequences, making our model suitable for use as an automated triaging system in radiology departments.
△ Less
Submitted 16 January, 2024; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Automated triaging of head MRI examinations using convolutional neural networks
Authors:
David A. Wood,
Sina Kafiabadi,
Ayisha Al Busaidi,
Emily Guilhem,
Antanas Montvila,
Siddharth Agarwal,
Jeremy Lynch,
Matthew Townend,
Gareth Barker,
Sebastien Ourselin,
James H. Cole,
Thomas C. Booth
Abstract:
The growing demand for head magnetic resonance imaging (MRI) examinations, along with a global shortage of radiologists, has led to an increase in the time taken to report head MRI scans around the world. For many neurological conditions, this delay can result in increased morbidity and mortality. An automated triaging tool could reduce reporting times for abnormal examinations by identifying abno…
▽ More
The growing demand for head magnetic resonance imaging (MRI) examinations, along with a global shortage of radiologists, has led to an increase in the time taken to report head MRI scans around the world. For many neurological conditions, this delay can result in increased morbidity and mortality. An automated triaging tool could reduce reporting times for abnormal examinations by identifying abnormalities at the time of imaging and prioritizing the reporting of these scans. In this work, we present a convolutional neural network for detecting clinically-relevant abnormalities in $\text{T}_2$-weighted head MRI scans. Using a validated neuroradiology report classifier, we generated a labelled dataset of 43,754 scans from two large UK hospitals for model training, and demonstrate accurate classification (area under the receiver operating curve (AUC) = 0.943) on a test set of 800 scans labelled by a team of neuroradiologists. Importantly, when trained on scans from only a single hospital the model generalized to scans from the other hospital ($Δ$AUC $\leq$ 0.02). A simulation study demonstrated that our model would reduce the mean reporting time for abnormal examinations from 28 days to 14 days and from 9 days to 5 days at the two hospitals, demonstrating feasibility for use in a clinical triage environment.
△ Less
Submitted 28 June, 2022; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Labelling imaging datasets on the basis of neuroradiology reports: a validation study
Authors:
David A. Wood,
Sina Kafiabadi,
Aisha Al Busaidi,
Emily Guilhem,
Jeremy Lynch,
Matthew Townend,
Antanas Montvila,
Juveria Siddiqui,
Naveen Gadapa,
Matthew Benger,
Gareth Barker,
Sebastian Ourselin,
James H. Cole,
Thomas C. Booth
Abstract:
Natural language processing (NLP) shows promise as a means to automate the labelling of hospital-scale neuroradiology magnetic resonance imaging (MRI) datasets for computer vision applications. To date, however, there has been no thorough investigation into the validity of this approach, including determining the accuracy of report labels compared to image labels as well as examining the performan…
▽ More
Natural language processing (NLP) shows promise as a means to automate the labelling of hospital-scale neuroradiology magnetic resonance imaging (MRI) datasets for computer vision applications. To date, however, there has been no thorough investigation into the validity of this approach, including determining the accuracy of report labels compared to image labels as well as examining the performance of non-specialist labellers. In this work, we draw on the experience of a team of neuroradiologists who labelled over 5000 MRI neuroradiology reports as part of a project to build a dedicated deep learning-based neuroradiology report classifier. We show that, in our experience, assigning binary labels (i.e. normal vs abnormal) to images from reports alone is highly accurate. In contrast to the binary labels, however, the accuracy of more granular labelling is dependent on the category, and we highlight reasons for this discrepancy. We also show that downstream model performance is reduced when labelling of training reports is performed by a non-specialist. To allow other researchers to accelerate their research, we make our refined abnormality definitions and labelling rules available, as well as our easy-to-use radiology report labelling app which helps streamline this process.
△ Less
Submitted 8 March, 2021; v1 submitted 8 July, 2020;
originally announced July 2020.
-
The gem5 Simulator: Version 20.0+
Authors:
Jason Lowe-Power,
Abdul Mutaal Ahmad,
Ayaz Akram,
Mohammad Alian,
Rico Amslinger,
Matteo Andreozzi,
Adrià Armejach,
Nils Asmussen,
Brad Beckmann,
Srikant Bharadwaj,
Gabe Black,
Gedare Bloom,
Bobby R. Bruce,
Daniel Rodrigues Carvalho,
Jeronimo Castrillon,
Lizhong Chen,
Nicolas Derumigny,
Stephan Diestelhorst,
Wendy Elsasser,
Carlos Escuin,
Marjan Fariborz,
Amin Farmahini-Farahani,
Pouya Fotouhi,
Ryan Gambord,
Jayneel Gandhi
, et al. (53 additional authors not shown)
Abstract:
The open-source and community-supported gem5 simulator is one of the most popular tools for computer architecture research. This simulation infrastructure allows researchers to model modern computer hardware at the cycle level, and it has enough fidelity to boot unmodified Linux-based operating systems and run full applications for multiple architectures including x86, Arm, and RISC-V. The gem5 si…
▽ More
The open-source and community-supported gem5 simulator is one of the most popular tools for computer architecture research. This simulation infrastructure allows researchers to model modern computer hardware at the cycle level, and it has enough fidelity to boot unmodified Linux-based operating systems and run full applications for multiple architectures including x86, Arm, and RISC-V. The gem5 simulator has been under active development over the last nine years since the original gem5 release. In this time, there have been over 7500 commits to the codebase from over 250 unique contributors which have improved the simulator by adding new features, fixing bugs, and increasing the code quality. In this paper, we give and overview of gem5's usage and features, describe the current state of the gem5 simulator, and enumerate the major changes since the initial release of gem5. We also discuss how the gem5 simulator has transitioned to a formal governance model to enable continued improvement and community support for the next 20 years of computer architecture research.
△ Less
Submitted 29 September, 2020; v1 submitted 6 July, 2020;
originally announced July 2020.
-
Automated Labelling using an Attention model for Radiology reports of MRI scans (ALARM)
Authors:
David A. Wood,
Jeremy Lynch,
Sina Kafiabadi,
Emily Guilhem,
Aisha Al Busaidi,
Antanas Montvila,
Thomas Varsavsky,
Juveria Siddiqui,
Naveen Gadapa,
Matthew Townend,
Martin Kiik,
Keena Patel,
Gareth Barker,
Sebastian Ourselin,
James H. Cole,
Thomas C. Booth
Abstract:
Labelling large datasets for training high-capacity neural networks is a major obstacle to the development of deep learning-based medical imaging applications. Here we present a transformer-based network for magnetic resonance imaging (MRI) radiology report classification which automates this task by assigning image labels on the basis of free-text expert radiology reports. Our model's performance…
▽ More
Labelling large datasets for training high-capacity neural networks is a major obstacle to the development of deep learning-based medical imaging applications. Here we present a transformer-based network for magnetic resonance imaging (MRI) radiology report classification which automates this task by assigning image labels on the basis of free-text expert radiology reports. Our model's performance is comparable to that of an expert radiologist, and better than that of an expert physician, demonstrating the feasibility of this approach. We make code available online for researchers to label their own MRI datasets for medical imaging applications.
△ Less
Submitted 16 February, 2020;
originally announced February 2020.
-
When to use 3D Die-Stacked Memory for Bandwidth-Constrained Big Data Workloads
Authors:
Jason Lowe-Power,
Mark D. Hill,
David A. Wood
Abstract:
Response time requirements for big data processing systems are shrinking. To meet this strict response time requirement, many big data systems store all or most of their data in main memory to reduce the access latency. Main memory capacities have grown, and systems with 2 TB of main memory capacity available today. However, the rate at which processors can access this data--the memory bandwidth--…
▽ More
Response time requirements for big data processing systems are shrinking. To meet this strict response time requirement, many big data systems store all or most of their data in main memory to reduce the access latency. Main memory capacities have grown, and systems with 2 TB of main memory capacity available today. However, the rate at which processors can access this data--the memory bandwidth--has not grown at the same rate. In fact, some of these big-memory systems can access less than 10% of their main memory capacity in one second (billions of processor cycles).
3D die-stacking is one promising solution to this bandwidth problem, and industry is investing significantly in 3D die-stacking. We use a simple back-of-the-envelope-style model to characterize if and when the 3D die-stacked architecture is more cost-effective than current architectures for in-memory big data workloads. We find that die-stacking has much higher performance than current systems (up to 256x lower response times), and it does not require expensive memory over provisioning to meet real-time (10 ms) response time service-level agreements. However, the power requirements of the die-stacked systems are significantly higher (up to 50x) than current systems, and its memory capacity is lower in many cases. Even in this limited case study, we find 3D die-stacking is not a panacea. Today, die-stacking is the most cost-effective solution for strict SLAs and by reducing the power of the compute chip and increasing memory densities die-stacking can be cost-effective under other constraints in the future.
△ Less
Submitted 26 August, 2016;
originally announced August 2016.