Kron Reduction and Effective Resistance of Directed Graphs
Authors:
Tomohiro Sugiyama,
Kazuhiro Sato
Abstract:
In network theory, the concept of effective resistance is a distance measure on a graph that relates the global network properties to individual connections between nodes. In addition, the Kron reduction method is a standard tool for reducing or eliminating the desired nodes, which preserves the interconnection structure and the effective resistance of the original graph. Although these two graph-…
▽ More
In network theory, the concept of effective resistance is a distance measure on a graph that relates the global network properties to individual connections between nodes. In addition, the Kron reduction method is a standard tool for reducing or eliminating the desired nodes, which preserves the interconnection structure and the effective resistance of the original graph. Although these two graph-theoretic concepts stem from the electric network on an undirected graph, they also have a number of applications throughout a wide variety of other fields. In this study, we propose a generalization of a Kron reduction for directed graphs. Furthermore, we prove that this reduction method preserves the structure of the original graphs, such as the strong connectivity or weight balance. In addition, we generalize the effective resistance to a directed graph using Markov chain theory, which is invariant under a Kron reduction. Although the effective resistance of our proposal is asymmetric, we prove that it induces two novel graph metrics in general strongly connected directed graphs. In particular, the effective resistance captures the commute and covering times for strongly connected weight balanced directed graphs. Finally, we compare our method with existing approaches and relate the hitting probability metrics and effective resistance in a stochastic case. In addition, we show that the effective resistance in a doubly stochastic case is the same as the resistance distance in an ergodic Markov chain.
△ Less
Submitted 28 October, 2022; v1 submitted 25 February, 2022;
originally announced February 2022.
Multi-scale Image Fusion Between Pre-operative Clinical CT and X-ray Microtomography of Lung Pathology
Authors:
Holger R. Roth,
Kai Nagara,
Hirohisa Oda,
Masahiro Oda,
Tomoshi Sugiyama,
Shota Nakamura,
Kensaku Mori
Abstract:
Computational anatomy allows the quantitative analysis of organs in medical images. However, most analysis is constrained to the millimeter scale because of the limited resolution of clinical computed tomography (CT). X-ray microtomography ($μ$CT) on the other hand allows imaging of ex-vivo tissues at a resolution of tens of microns. In this work, we use clinical CT to image lung cancer patients b…
▽ More
Computational anatomy allows the quantitative analysis of organs in medical images. However, most analysis is constrained to the millimeter scale because of the limited resolution of clinical computed tomography (CT). X-ray microtomography ($μ$CT) on the other hand allows imaging of ex-vivo tissues at a resolution of tens of microns. In this work, we use clinical CT to image lung cancer patients before partial pneumonectomy (resection of pathological lung tissue). The resected specimen is prepared for $μ$CT imaging at a voxel resolution of 50 $μ$m (0.05 mm). This high-resolution image of the lung cancer tissue allows further insides into understanding of tumor growth and categorization. For making full use of this additional information, image fusion (registration) needs to be performed in order to re-align the $μ$CT image with clinical CT. We developed a multi-scale non-rigid registration approach. After manual initialization using a few landmark points and rigid alignment, several levels of non-rigid registration between down-sampled (in the case of $μ$CT) and up-sampled (in the case of clinical CT) representations of the image are performed. Any non-lung tissue is ignored during the computation of the similarity measure used to guide the registration during optimization. We are able to recover the volume differences introduced by the resection and preparation of the lung specimen. The average ($\pm$ std. dev.) minimum surface distance between $μ$CT and clinical CT at the resected lung surface is reduced from 3.3 $\pm$ 2.9 (range: [0.1, 15.9]) to 2.3 mm $\pm$ 2.8 (range: [0.0, 15.3]) mm. The alignment of clinical CT with $μ$CT will allow further registration with even finer resolutions of $μ$CT (up to 10 $μ$m resolution) and ultimately with histopathological microscopy images for further macro to micro image fusion that can aid medical image analysis.
△ Less
Submitted 27 February, 2017;
originally announced February 2017.