Developments in Mathematical Algorithms and Computational Tools for Proton CT and Particle Therapy Treatment Planning
Authors:
Yair Censor,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy necessitates a high level of delivery accuracy to exploit the selective targeting imparted by the Bragg peak. For this purpose, pCT utilizes the proton beam itself to…
▽ More
We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy necessitates a high level of delivery accuracy to exploit the selective targeting imparted by the Bragg peak. For this purpose, pCT utilizes the proton beam itself to create images. The technique works by sending a low-intensity beam of protons through the patient and measuring the position, direction, and energy loss of each exiting proton. The pCT technique allows reconstruction of the volumetric distribution of the relative stop** power (RSP) of the patient tissues for use in treatment planning and pre-treatment range verification. We have investigated new ways to make the reconstruction both efficient and accurate. Better accuracy of RSP also enables more robust inverse approaches to IMPT. For IMPT, we developed a framework for performing intensity-modulation of the proton pencil beams. We expect that these developments will lead to additional project work in the years to come, which requires a regular exchange between experts in the fields of mathematics, computer science, and medical physics. We have initiated such an exchange by organizing annual workshops on pCT and IMPT algorithm and technology developments. This report is, admittedly, tilted toward our interdisciplinary work and methods. We offer a comprehensive overview of results, problems, and challenges in pCT and IMPT with the aim of making other scientists wanting to tackle such issues and to strengthen their interdisciplinary collaboration by bringing together cutting-edge know-how from medicine, computer science, physics, and mathematics to bear on medical physics problems at hand.
△ Less
Submitted 21 August, 2021;
originally announced August 2021.
-
An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography
Authors:
Blake Schultze,
Yair Censor,
Paniz Karbasi,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
Previous work showed that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this work investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structural and parametric changes introduced to the original TVS algorithm included: (1) inc…
▽ More
Previous work showed that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this work investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structural and parametric changes introduced to the original TVS algorithm included: (1) inclusion or exclusion of TV reduction requirement, (2) a variable number, $N$, of TV perturbation steps per feasibility-seeking iteration, and (3) introduction of a perturbation kernel $0<α<1$. The structural change of excluding the TV reduction requirement check tended to have a beneficial effect for $3\le N\le 6$ and allows full parallelization of the TVS algorithm. Repeated perturbations per feasibility-seeking iterations reduced total variation (TV) and material dependent standard deviations for $3\le N\le 6$. The perturbation kernel $α$, equivalent to $α=0.5$ in the original TVS algorithm, reduced TV and standard deviations as $α$ was increased beyond $α=0.5$, but negatively impacted reconstructed relative stop** power (RSP) values for $α>0.75$. The reductions in TV and standard deviations allowed feasibility-seeking with a larger relaxation parameter $λ$ than previously used, without the corresponding increases in standard deviations experienced with the original TVS algorithm. This work demonstrates that the modifications related to the evolution of the original TVS algorithm provide benefits in terms of both pCT image quality and computational efficiency for appropriately chosen parameter values.
△ Less
Submitted 17 January, 2019; v1 submitted 3 March, 2018;
originally announced March 2018.
-
A Highly Accelerated Parallel Multi-GPU based Reconstruction Algorithm for Generating Accurate Relative Stop** Powers
Authors:
Paniz Karbasi,
Ritchie Cai,
Blake Schultze,
Hanh Nguyen,
Jones Reed,
Patrick Hall,
Valentina Giacometti,
Vladimir Bashkirov,
Robert Johnson,
Nick Karonis,
Jeffrey Olafsen,
Caesar Ordonez,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stop** Power (RSP) measurements with high accuracy within clinically required time frames. Generating accurate RSP values within the shortest amount of time is considered a key goal when…
▽ More
Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stop** Power (RSP) measurements with high accuracy within clinically required time frames. Generating accurate RSP values within the shortest amount of time is considered a key goal when develo** a pCT software. The existing pCT softwares have successfully met this time frame and even succeeded this time goal, but requiring clusters with hundreds of processors.
This paper describes a novel reconstruction technique using two Graphics Processing Unit (GPU) cores, such as is available on a single Nvidia P100. The proposed reconstruction technique is tested on both simulated and experimental datasets and on two different systems namely Nvidia K40 and P100 GPUs from IBM and Cray. The experimental results demonstrate that our proposed reconstruction method meets both the timing and accuracy with the benefit of having reasonable cost, and efficient use of power.
△ Less
Submitted 3 February, 2018;
originally announced February 2018.