Neural Network Reconstruction of the Left Atrium using Sparse Catheter Paths
Authors:
Alon Baram,
Moshe Safran,
Tomer Noy,
Naveh Geri,
Hayit Greenspan
Abstract:
Catheter based radiofrequency ablation for pulmonary vein isolation has become the first line of treatment for atrial fibrillation in recent years. This requires a rather accurate map of the left atrial sub-endocardial surface including the ostia of the pulmonary veins, which requires dense sampling of the surface and takes more than 10 minutes. The focus of this work is to provide left atrial vis…
▽ More
Catheter based radiofrequency ablation for pulmonary vein isolation has become the first line of treatment for atrial fibrillation in recent years. This requires a rather accurate map of the left atrial sub-endocardial surface including the ostia of the pulmonary veins, which requires dense sampling of the surface and takes more than 10 minutes. The focus of this work is to provide left atrial visualization early in the procedure to ease procedure complexity and enable further workflows, such as using catheters that have difficulty sampling the surface. We propose a dense encoder-decoder network with a novel regularization term to reconstruct the shape of the left atrium from partial data which is derived from simple catheter maneuvers. To train the network, we acquire a large dataset of 3D atria shapes and generate corresponding catheter trajectories. Once trained, we show that the suggested network can sufficiently approximate the atrium shape based on a given trajectory. We compare several network solutions for the 3D atrium reconstruction. We demonstrate that the solution proposed produces realistic visualization using partial acquisition within a 3-minute time interval. Synthetic and human clinical cases are shown.
△ Less
Submitted 4 November, 2023;
originally announced November 2023.
Addressing Uncertainty in Imbalanced Histopathology Image Classification of HER2 Breast Cancer: An interpretable Ensemble Approach with Threshold Filtered Single Instance Evaluation (SIE)
Authors:
Md Sakib Hossain Shovon,
M. F. Mridha,
Khan Md Hasib,
Sultan Alfarhood,
Mejdl Safran,
Dunren Che
Abstract:
Breast Cancer (BC) is among women's most lethal health concerns. Early diagnosis can alleviate the mortality rate by hel** patients make efficient treatment decisions. Human Epidermal Growth Factor Receptor (HER2) has become one the most lethal subtype of BC. According to the College of American Pathologists American Society of Clinical Oncology (CAP/ASCO), the severity level of HER2 expression…
▽ More
Breast Cancer (BC) is among women's most lethal health concerns. Early diagnosis can alleviate the mortality rate by hel** patients make efficient treatment decisions. Human Epidermal Growth Factor Receptor (HER2) has become one the most lethal subtype of BC. According to the College of American Pathologists American Society of Clinical Oncology (CAP/ASCO), the severity level of HER2 expression can be classified between 0 and 3+ range. HER2 can be detected effectively from immunohistochemical (IHC) and, hematoxylin & eosin (HE) images of different classes such as 0, 1+, 2+, and 3+. An ensemble approach integrated with threshold filtered single instance evaluation (SIE) technique has been proposed in this study to diagnose BC from the multi-categorical expression of HER2 subtypes. Initially, DenseNet201 and Xception have been ensembled into a single classifier as feature extractors with an effective combination of global average pooling, dropout layer, dense layer with a swish activation function, and l2 regularizer, batch normalization, etc. After that, extracted features has been processed through single instance evaluation (SIE) to determine different confidence levels and adjust decision boundary among the imbalanced classes. This study has been conducted on the BC immunohistochemical (BCI) dataset, which is classified by pathologists into four stages of HER2 BC. This proposed approach known as DenseNet201-Xception-SIE with a threshold value of 0.7 surpassed all other existing state-of-art models with an accuracy of 97.12%, precision of 97.15%, and recall of 97.68% on H&E data and, accuracy of 97.56%, precision of 97.57%, and recall of 98.00% on IHC data respectively, maintaining momentous improvement. Finally, Grad-CAM and Guided Grad-CAM have been employed in this study to interpret, how TL-based model works on the histopathology dataset and make decisions from the data.
△ Less
Submitted 26 October, 2023; v1 submitted 1 August, 2023;
originally announced August 2023.