Patch-based field-of-view matching in multi-modal images for electroporation-based ablations
Authors:
Luc Lafitte,
Rémi Giraud,
Cornel Zachiu,
Mario Ries,
Olivier Sutter,
Antoine Petit,
Olivier Seror,
Clair Poignard,
Baudouin Denis de Senneville
Abstract:
Various multi-modal imaging sensors are currently involved at different steps of an interventional therapeutic work-flow. Cone beam computed tomography (CBCT), computed tomography (CT) or Magnetic Resonance (MR) images thereby provides complementary functional and/or structural information of the targeted region and organs at risk. Merging this information relies on a correct spatial alignment of…
▽ More
Various multi-modal imaging sensors are currently involved at different steps of an interventional therapeutic work-flow. Cone beam computed tomography (CBCT), computed tomography (CT) or Magnetic Resonance (MR) images thereby provides complementary functional and/or structural information of the targeted region and organs at risk. Merging this information relies on a correct spatial alignment of the observed anatomy between the acquired images. This can be achieved by the means of multi-modal deformable image registration (DIR), demonstrated to be capable of estimating dense and elastic deformations between images acquired by multiple imaging devices. However, due to the typically different field-of-view (FOV) sampled across the various imaging modalities, such algorithms may severely fail in finding a satisfactory solution.
In the current study we propose a new fast method to align the FOV in multi-modal 3D medical images. To this end, a patch-based approach is introduced and combined with a state-of-the-art multi-modal image similarity metric in order to cope with multi-modal medical images. The occurrence of estimated patch shifts is computed for each spatial direction and the shift value with maximum occurrence is selected and used to adjust the image field-of-view.
We show that a regional registration approach using voxel patches provides a good structural compromise between the voxel-wise and "global shifts" approaches. The method was thereby beneficial for CT to CBCT and MRI to CBCT registration tasks, especially when highly different image FOVs are involved. Besides, the benefit of the method for CT to CBCT and MRI to CBCT image registration is analyzed, including the impact of artifacts generated by percutaneous needle insertions. Additionally, the computational needs are demonstrated to be compatible with clinical constraints in the practical case of on-line procedures.
△ Less
Submitted 9 November, 2020;
originally announced November 2020.
-
MRI-Guided High Intensity Focused Ultrasound of Liver and Kidney
Authors:
Baudouin Denis de Senneville,
Mario Ries,
Wilbert Bartels,
Chrit Moonen
Abstract:
High Intensity Focused Ultrasound (HIFU) can be used to achieve a local temperature increase deep inside the human body in a non-invasive way. MRI guidance of the procedure allows in situ target definition. In addition, MRI can be used to provide continuous temperature map** during HIFU for spatial and temporal control of the heating procedure and prediction of the final lesion based on the rece…
▽ More
High Intensity Focused Ultrasound (HIFU) can be used to achieve a local temperature increase deep inside the human body in a non-invasive way. MRI guidance of the procedure allows in situ target definition. In addition, MRI can be used to provide continuous temperature map** during HIFU for spatial and temporal control of the heating procedure and prediction of the final lesion based on the received thermal dose. Temperature map** of mobile organs as kidney and liver is challenging, as well as real-time processing methods for feedback control of the HIFU procedure. In this paper, recent technological advances are reviewed in MR temperature map** of these organs, in motion compensation of the HIFU beam, in intercostal HIFU sonication, and in volumetric ablation and feedback control strategies. Recent pre-clinical studies have demonstrated the feasibility of each of these novel methods. The perspectives to translate those advances into the clinic are addressed. It can be concluded that MR guided HIFU for ablation in liver and kidney appears feasible but requires further work on integration of technologically advanced methods.
△ Less
Submitted 21 November, 2020;
originally announced November 2020.
-
Deep correction of breathing-related artifacts in real-time MR-thermometry
Authors:
Baudouin Denis de Senneville,
Pierrick Coupé,
Mario Ries,
Laurent Facq,
Chrit Moonen
Abstract:
Real-time MR-imaging has been clinically adapted for monitoring thermal therapies since it can provide on-the-fly temperature maps simultaneously with anatomical information. However, proton resonance frequency based thermometry of moving targets remains challenging since temperature artifacts are induced by the respiratory as well as physiological motion. If left uncorrected, these artifacts lead…
▽ More
Real-time MR-imaging has been clinically adapted for monitoring thermal therapies since it can provide on-the-fly temperature maps simultaneously with anatomical information. However, proton resonance frequency based thermometry of moving targets remains challenging since temperature artifacts are induced by the respiratory as well as physiological motion. If left uncorrected, these artifacts lead to severe errors in temperature estimates and impair therapy guidance. In this study, we evaluated deep learning for on-line correction of motion related errors in abdominal MR-thermometry. For this, a convolutional neural network (CNN) was designed to learn the apparent temperature perturbation from images acquired during a preparative learning stage prior to hyperthermia. The input of the designed CNN is the most recent magnitude image and no surrogate of motion is needed. During the subsequent hyperthermia procedure, the recent magnitude image is used as an input for the CNN-model in order to generate an on-line correction for the current temperature map. The method's artifact suppression performance was evaluated on 12 free breathing volunteers and was found robust and artifact-free in all examined cases. Furthermore, thermometric precision and accuracy was assessed for in vivo ablation using high intensity focused ultrasound. All calculations involved at the different stages of the proposed workflow were designed to be compatible with the clinical time constraints of a therapeutic procedure.
△ Less
Submitted 22 December, 2020; v1 submitted 10 November, 2020;
originally announced November 2020.
-
iDataCool: HPC with Hot-Water Cooling and Energy Reuse
Authors:
Nils Meyer,
Manfred Ries,
Stefan Solbrig,
Tilo Wettig
Abstract:
iDataCool is an HPC architecture jointly developed by the University of Regensburg and the IBM Research and Development Lab Böblingen. It is based on IBM's iDataPlex platform, whose air-cooling solution was replaced by a custom water-cooling solution that allows for cooling water temperatures of 70C/158F. The system is coupled to an adsorption chiller by InvenSor that operates efficiently at these…
▽ More
iDataCool is an HPC architecture jointly developed by the University of Regensburg and the IBM Research and Development Lab Böblingen. It is based on IBM's iDataPlex platform, whose air-cooling solution was replaced by a custom water-cooling solution that allows for cooling water temperatures of 70C/158F. The system is coupled to an adsorption chiller by InvenSor that operates efficiently at these temperatures. Thus a significant portion of the energy spent on HPC can be recovered in the form of chilled water, which can then be used to cool other parts of the computing center. We describe the architecture of iDataCool and present benchmarks of the cooling performance and the energy (reuse) efficiency.
△ Less
Submitted 19 September, 2013;
originally announced September 2013.
-
QPACE -- a QCD parallel computer based on Cell processors
Authors:
H. Baier,
H. Boettiger,
M. Drochner,
N. Eicker,
U. Fischer,
Z. Fodor,
A. Frommer,
C. Gomez,
G. Goldrian,
S. Heybrock,
D. Hierl,
M. Hüsken,
T. Huth,
B. Krill,
J. Lauritsen,
T. Lippert,
T. Maurer,
B. Mendl,
N. Meyer,
A. Nobile,
I. Ouda,
M. Pivanti,
D. Pleiter,
M. Ries,
A. Schäfer
, et al. (10 additional authors not shown)
Abstract:
QPACE is a novel parallel computer which has been developed to be primarily used for lattice QCD simulations. The compute power is provided by the IBM PowerXCell 8i processor, an enhanced version of the Cell processor that is used in the Playstation 3. The QPACE nodes are interconnected by a custom, application optimized 3-dimensional torus network implemented on an FPGA. To achieve the very hig…
▽ More
QPACE is a novel parallel computer which has been developed to be primarily used for lattice QCD simulations. The compute power is provided by the IBM PowerXCell 8i processor, an enhanced version of the Cell processor that is used in the Playstation 3. The QPACE nodes are interconnected by a custom, application optimized 3-dimensional torus network implemented on an FPGA. To achieve the very high packaging density of 26 TFlops per rack a new water cooling concept has been developed and successfully realized. In this paper we give an overview of the architecture and highlight some important technical details of the system. Furthermore, we provide initial performance results and report on the installation of 8 QPACE racks providing an aggregate peak performance of 200 TFlops.
△ Less
Submitted 23 December, 2009; v1 submitted 11 November, 2009;
originally announced November 2009.