Reconstruction of Undersampled 3D Non-Cartesian Image-Based Navigators for Coronary MRA Using an Unrolled Deep Learning Model
Authors:
Mario O. Malavé,
Corey A. Baron,
Srivathsan P. Koundinyan,
Christopher M. Sandino,
Frank Ong,
Joseph Y. Cheng,
Dwight G. Nishimura
Abstract:
Purpose: To rapidly reconstruct undersampled 3D non-Cartesian image-based navigators (iNAVs) using an unrolled deep learning (DL) model for non-rigid motion correction in coronary magnetic resonance angiography (CMRA).
Methods: An unrolled network is trained to reconstruct beat-to-beat 3D iNAVs acquired as part of a CMRA sequence. The unrolled model incorporates a non-uniform FFT operator to per…
▽ More
Purpose: To rapidly reconstruct undersampled 3D non-Cartesian image-based navigators (iNAVs) using an unrolled deep learning (DL) model for non-rigid motion correction in coronary magnetic resonance angiography (CMRA).
Methods: An unrolled network is trained to reconstruct beat-to-beat 3D iNAVs acquired as part of a CMRA sequence. The unrolled model incorporates a non-uniform FFT operator to perform the data consistency operation, and the regularization term is learned by a convolutional neural network (CNN) based on the proximal gradient descent algorithm. The training set includes 6,000 3D iNAVs acquired from 7 different subjects and 11 scans using a variable-density (VD) cones trajectory. For testing, 3D iNAVs from 4 additional subjects are reconstructed using the unrolled model. To validate reconstruction accuracy, global and localized motion estimates from DL model-based 3D iNAVs are compared with those extracted from 3D iNAVs reconstructed with $\textit{l}_{1}$-ESPIRiT. Then, the high-resolution coronary MRA images motion corrected with autofocusing using the $\textit{l}_{1}$-ESPIRiT and DL model-based 3D iNAVs are assessed for differences.
Results: 3D iNAVs reconstructed using the DL model-based approach and conventional $\textit{l}_{1}$-ESPIRiT generate similar global and localized motion estimates and provide equivalent coronary image quality. Reconstruction with the unrolled network completes in a fraction of the time compared to CPU and GPU implementations of $\textit{l}_{1}$-ESPIRiT (20x and 3x speed increases, respectively).
Conclusion: We have developed a deep neural network architecture to reconstruct undersampled 3D non-Cartesian VD cones iNAVs. Our approach decreases reconstruction time for 3D iNAVs, while preserving the accuracy of non-rigid motion information offered by them for correction.
△ Less
Submitted 24 October, 2019;
originally announced October 2019.
Deep Residual Network for Off-Resonance Artifact Correction with Application to Pediatric Body Magnetic Resonance Angiography with 3D Cones
Authors:
David Y Zeng,
Jamil Shaikh,
Dwight G Nishimura,
Shreyas S Vasanawala,
Joseph Y Cheng
Abstract:
Purpose: Off-resonance artifact correction by deep-learning, to facilitate rapid pediatric body imaging with a scan time efficient 3D cones trajectory. Methods: A residual convolutional neural network to correct off-resonance artifacts (Off-ResNet) was trained with a prospective study of 30 pediatric magnetic resonance angiography exams. Each exam acquired a short-readout scan (1.18 ms +- 0.38) an…
▽ More
Purpose: Off-resonance artifact correction by deep-learning, to facilitate rapid pediatric body imaging with a scan time efficient 3D cones trajectory. Methods: A residual convolutional neural network to correct off-resonance artifacts (Off-ResNet) was trained with a prospective study of 30 pediatric magnetic resonance angiography exams. Each exam acquired a short-readout scan (1.18 ms +- 0.38) and a long-readout scan (3.35 ms +- 0.74) at 3T. Short-readout scans, with longer scan times but negligible off-resonance blurring, were used as reference images and augmented with additional off-resonance for supervised training examples. Long-readout scans, with greater off-resonance artifacts but shorter scan time, were corrected by autofocus and Off-ResNet and compared to short-readout scans by normalized root-mean-square error (NRMSE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR). Scans were also compared by scoring on eight anatomical features by two radiologists, using analysis of variance with post-hoc Tukey's test. Reader agreement was determined with intraclass correlation. Results: Long-readout scans were on average 59.3% shorter than short-readout scans. Images from Off-ResNet had superior NRMSE, SSIM, and PSNR compared to uncorrected images across +-1kHz off-resonance (P<0.01). The proposed method had superior NRMSE over -677Hz to +1kHz and superior SSIM and PSNR over +-1kHz compared to autofocus (P<0.01). Radiologic scoring demonstrated that long-readout scans corrected with Off-ResNet were non-inferior to short-readout scans (P<0.01). Conclusion: The proposed method can correct off-resonance artifacts from rapid long-readout 3D cones scans to a non-inferior image quality compared to diagnostically standard short-readout scans.
△ Less
Submitted 28 September, 2018;
originally announced October 2018.