Unsupervised ore/waste classification on open-cut mine faces using close-range hyperspectral data
Authors:
Lloyd Windrim,
Arman Melkumyan,
Richard J. Murphy,
Anna Chlingaryan,
Raymond Leung
Abstract:
The remote map** of minerals and discrimination of ore and waste on surfaces are important tasks for geological applications such as those in mining. Such tasks have become possible using ground-based, close-range hyperspectral sensors which can remotely measure the reflectance properties of the environment with high spatial and spectral resolution. However, autonomous map** of mineral spectra…
▽ More
The remote map** of minerals and discrimination of ore and waste on surfaces are important tasks for geological applications such as those in mining. Such tasks have become possible using ground-based, close-range hyperspectral sensors which can remotely measure the reflectance properties of the environment with high spatial and spectral resolution. However, autonomous map** of mineral spectra measured on an open-cut mine face remains a challenging problem due to the subtleness of differences in spectral absorption features between mineral and rock classes as well as variability in the illumination of the scene. An additional layer of difficulty arises when there is no annotated data available to train a supervised learning algorithm. A pipeline for unsupervised map** of spectra on a mine face is proposed which draws from several recent advances in the hyperspectral machine learning literature. The proposed pipeline brings together unsupervised and self-supervised algorithms in a unified system to map minerals on a mine face without the need for human-annotated training data. The pipeline is evaluated with a hyperspectral image dataset of an open-cut mine face comprising mineral ore martite and non-mineralised shale. The combined system is shown to produce a superior map to its constituent algorithms, and the consistency of its map** capability is demonstrated using data acquired at two different times of day.
△ Less
Submitted 9 February, 2023;
originally announced February 2023.
Pose Estimation of Periacetabular Osteotomy Fragments with Intraoperative X-Ray Navigation
Authors:
Robert B. Grupp,
Rachel A. Hegeman,
Ryan J. Murphy,
Clayton P. Alexander,
Yoshito Otake,
Benjamin A. McArthur,
Mehran Armand,
Russell H. Taylor
Abstract:
Objective: State of the art navigation systems for pelvic osteotomies use optical systems with external fiducials. We propose the use of X-Ray navigation for pose estimation of periacetabular fragments without fiducials. Methods: A 2D/3D registration pipeline was developed to recover fragment pose. This pipeline was tested through an extensive simulation study and 6 cadaveric surgeries. Using oste…
▽ More
Objective: State of the art navigation systems for pelvic osteotomies use optical systems with external fiducials. We propose the use of X-Ray navigation for pose estimation of periacetabular fragments without fiducials. Methods: A 2D/3D registration pipeline was developed to recover fragment pose. This pipeline was tested through an extensive simulation study and 6 cadaveric surgeries. Using osteotomy boundaries in the fluoroscopic images, the preoperative plan is refined to more accurately match the intraoperative shape. Results: In simulation, average fragment pose errors were 1.3°/1.7 mm when the planned fragment matched the intraoperative fragment, 2.2°/2.1 mm when the plan was not updated to match the true shape, and 1.9°/2.0 mm when the fragment shape was intraoperatively estimated. In cadaver experiments, the average pose errors were 2.2°/2.2 mm, 3.8°/2.5 mm, and 3.5°/2.2 mm when registering with the actual fragment shape, a preoperative plan, and an intraoperatively refined plan, respectively. Average errors of the lateral center edge angle were less than 2° for all fragment shapes in simulation and cadaver experiments. Conclusion: The proposed pipeline is capable of accurately reporting femoral head coverage within a range clinically identified for long-term joint survivability. Significance: Human interpretation of fragment pose is challenging and usually restricted to rotation about a single anatomical axis. The proposed pipeline provides an intraoperative estimate of rigid pose with respect to all anatomical axes, is compatible with minimally invasive incisions, and has no dependence on external fiducials.
△ Less
Submitted 9 May, 2019; v1 submitted 21 March, 2019;
originally announced March 2019.