-
Towards a quantitative assessment of neurodegeneration in Alzheimer's disease
Authors:
Oleg Michailovich,
Rinat Mukhometzianov
Abstract:
Alzheimer's disease (AD) is an irreversible neurodegenerative disorder that progressively destroys memory and other cognitive domains of the brain. While effective therapeutic management of AD is still in development, it seems reasonable to expect their prospective outcomes to depend on the severity of baseline pathology. For this reason, substantial research efforts have been invested in the deve…
▽ More
Alzheimer's disease (AD) is an irreversible neurodegenerative disorder that progressively destroys memory and other cognitive domains of the brain. While effective therapeutic management of AD is still in development, it seems reasonable to expect their prospective outcomes to depend on the severity of baseline pathology. For this reason, substantial research efforts have been invested in the development of effective means of non-invasive diagnosis of AD at its earliest possible stages. In pursuit of the same objective, the present paper addresses the problem of the quantitative diagnosis of AD by means of Diffusion Magnetic Resonance Imaging (dMRI). In particular, the paper introduces the notion of a pathology specific imaging contrast (PSIC), which, in addition to supplying a valuable diagnostic score, can serve as a means of visual representation of the spatial extent of neurodegeneration. The values of PSIC are computed by a dedicated deep neural network (DNN), which has been specially adapted to the processing of dMRI signals. Once available, such values can be used for several important purposes, including stratification of study subjects. In particular, experiments confirm the DNN-based classification can outperform a wide range of alternative approaches in application to the basic problem of stratification of cognitively normal (CN) and AD subjects. Notwithstanding its preliminary nature, this result suggests a strong rationale for further extension and improvement of the explorative methodology described in this paper.
△ Less
Submitted 6 November, 2020;
originally announced November 2020.
-
Towards learned optimal q-space sampling in diffusion MRI
Authors:
Tomer Weiss,
Sanketh Vedula,
Ortal Senouf,
Oleg Michailovich,
AlexBronstein
Abstract:
Fiber tractography is an important tool of computational neuroscience that enables reconstructing the spatial connectivity and organization of white matter of the brain. Fiber tractography takes advantage of diffusion Magnetic Resonance Imaging (dMRI) which allows measuring the apparent diffusivity of cerebral water along different spatial directions. Unfortunately, collecting such data comes at t…
▽ More
Fiber tractography is an important tool of computational neuroscience that enables reconstructing the spatial connectivity and organization of white matter of the brain. Fiber tractography takes advantage of diffusion Magnetic Resonance Imaging (dMRI) which allows measuring the apparent diffusivity of cerebral water along different spatial directions. Unfortunately, collecting such data comes at the price of reduced spatial resolution and substantially elevated acquisition times, which limits the clinical applicability of dMRI. This problem has been thus far addressed using two principal strategies. Most of the efforts have been extended towards improving the quality of signal estimation for any, yet fixed sampling scheme (defined through the choice of diffusion-encoding gradients). On the other hand, optimization over the sampling scheme has also proven to be effective. Inspired by the previous results, the present work consolidates the above strategies into a unified estimation framework, in which the optimization is carried out with respect to both estimation model and sampling design {\it concurrently}. The proposed solution offers substantial improvements in the quality of signal estimation as well as the accuracy of ensuing analysis by means of fiber tractography. While proving the optimality of the learned estimation models would probably need more extensive evaluation, we nevertheless claim that the learned sampling schemes can be of immediate use, offering a way to improve the dMRI analysis without the necessity of deploying the neural network used for their estimation. We present a comprehensive comparative analysis based on the Human Connectome Project data. Code and learned sampling designs aviliable at https://github.com/tomer196/Learned_dMRI.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.
-
On segmentation of pectoralis muscle in digital mammograms by means of deep learning
Authors:
Hossein Soleimani,
Oleg V. Michailovich
Abstract:
Computer-aided diagnosis (CAD) has long become an integral part of radiological management of breast disease, facilitating a number of important clinical applications, including quantitative assessment of breast density and early detection of malignancies based on X-ray mammography. Common to such applications is the need to automatically discriminate between breast tissue and adjacent anatomy, wi…
▽ More
Computer-aided diagnosis (CAD) has long become an integral part of radiological management of breast disease, facilitating a number of important clinical applications, including quantitative assessment of breast density and early detection of malignancies based on X-ray mammography. Common to such applications is the need to automatically discriminate between breast tissue and adjacent anatomy, with the latter being predominantly represented by pectoralis major (or pectoral muscle). Especially in the case of mammograms acquired in the mediolateral oblique (MLO) view, the muscle is easily confusable with some elements of breast anatomy due to their morphological and photometric similarity. As a result, the problem of automatic detection and segmentation of pectoral muscle in MLO mammograms remains a challenging task, innovative approaches to which are still required and constantly searched for. To address this problem, the present paper introduces a two-step segmentation strategy based on a combined use of data-driven prediction (deep learning) and graph-based image processing. In particular, the proposed method employs a convolutional neural network (CNN) which is designed to predict the location of breast-pectoral boundary at different levels of spatial resolution. Subsequently, the predictions are used by the second stage of the algorithm, in which the desired boundary is recovered as a solution to the shortest path problem on a specially designed graph. The proposed algorithm has been tested on three different datasets (i.e., MIAS, CBIS-DDSm and InBreast) using a range of quantitative metrics. The results of comparative analysis show considerable improvement over state-of-the-art, while offering the possibility of model-free and fully automatic processing.
△ Less
Submitted 28 August, 2020;
originally announced August 2020.
-
Optimization of Structural Similarity in Mathematical Imaging
Authors:
D. Otero,
D. La Torre,
O. Michailovich,
E. R. Vrscay
Abstract:
It is now generally accepted that Euclidean-based metrics may not always adequately represent the subjective judgement of a human observer. As a result, many image processing methodologies have been recently extended to take advantage of alternative visual quality measures, the most prominent of which is the Structural Similarity Index Measure (SSIM). The superiority of the latter over Euclidean-b…
▽ More
It is now generally accepted that Euclidean-based metrics may not always adequately represent the subjective judgement of a human observer. As a result, many image processing methodologies have been recently extended to take advantage of alternative visual quality measures, the most prominent of which is the Structural Similarity Index Measure (SSIM). The superiority of the latter over Euclidean-based metrics have been demonstrated in several studies. However, being focused on specific applications, the findings of such studies often lack generality which, if otherwise acknowledged, could have provided a useful guidance for further development of SSIM-based image processing algorithms. Accordingly, instead of focusing on a particular image processing task, in this paper, we introduce a general framework that encompasses a wide range of imaging applications in which the SSIM can be employed as a fidelity measure. Subsequently, we show how the framework can be used to cast some standard as well as original imaging tasks into optimization problems, followed by a discussion of a number of novel numerical strategies for their solution.
△ Less
Submitted 7 February, 2020;
originally announced February 2020.
-
PILOT: Physics-Informed Learned Optimized Trajectories for Accelerated MRI
Authors:
Tomer Weiss,
Ortal Senouf,
Sanketh Vedula,
Oleg Michailovich,
Michael Zibulevsky,
Alex Bronstein
Abstract:
Magnetic Resonance Imaging (MRI) has long been considered to be among "the gold standards" of diagnostic medical imaging. The long acquisition times, however, render MRI prone to motion artifacts, let alone their adverse contribution to the relative high costs of MRI examination. Over the last few decades, multiple studies have focused on the development of both physical and post-processing method…
▽ More
Magnetic Resonance Imaging (MRI) has long been considered to be among "the gold standards" of diagnostic medical imaging. The long acquisition times, however, render MRI prone to motion artifacts, let alone their adverse contribution to the relative high costs of MRI examination. Over the last few decades, multiple studies have focused on the development of both physical and post-processing methods for accelerated acquisition of MRI scans. These two approaches, however, have so far been addressed separately. On the other hand, recent works in optical computational imaging have demonstrated growing success of concurrent learning-based design of data acquisition and image reconstruction schemes. Such schemes have already demonstrated substantial effectiveness, leading to considerably shorter acquisition times and improved quality of image reconstruction. Inspired by this initial success, in this work, we propose a novel approach to the learning of optimal schemes for conjoint acquisition and reconstruction of MRI scans, with the optimization carried out simultaneously with respect to the time-efficiency of data acquisition and the quality of resulting reconstructions. To be of a practical value, the schemes are encoded in the form of general k-space trajectories, whose associated magnetic gradients are constrained to obey a set of predefined hardware requirements (as defined in terms of, e.g., peak currents and maximum slew rates of magnetic gradients). With this proviso in mind, we propose a novel algorithm for the end-to-end training of a combined acquisition-reconstruction pipeline using a deep neural network with differentiable forward- and back-propagation operators. We demonstrate its effectiveness on image reconstruction and image segmentation tasks, reporting substantial improvements in terms of acceleration factors as well as the quality of these tasks.
△ Less
Submitted 13 April, 2021; v1 submitted 12 September, 2019;
originally announced September 2019.
-
Self-supervised learning of inverse problem solvers in medical imaging
Authors:
Ortal Senouf,
Sanketh Vedula,
Tomer Weiss,
Alex Bronstein,
Oleg Michailovich,
Michael Zibulevsky
Abstract:
In the past few years, deep learning-based methods have demonstrated enormous success for solving inverse problems in medical imaging. In this work, we address the following question:\textit{Given a set of measurements obtained from real imaging experiments, what is the best way to use a learnable model and the physics of the modality to solve the inverse problem and reconstruct the latent image?}…
▽ More
In the past few years, deep learning-based methods have demonstrated enormous success for solving inverse problems in medical imaging. In this work, we address the following question:\textit{Given a set of measurements obtained from real imaging experiments, what is the best way to use a learnable model and the physics of the modality to solve the inverse problem and reconstruct the latent image?} Standard supervised learning based methods approach this problem by collecting data sets of known latent images and their corresponding measurements. However, these methods are often impractical due to the lack of availability of appropriately sized training sets, and, more generally, due to the inherent difficulty in measuring the "groundtruth" latent image. In light of this, we propose a self-supervised approach to training inverse models in medical imaging in the absence of aligned data. Our method only requiring access to the measurements and the forward model at training. We showcase its effectiveness on inverse problems arising in accelerated magnetic resonance imaging (MRI).
△ Less
Submitted 22 May, 2019;
originally announced May 2019.
-
Joint learning of cartesian undersampling and reconstruction for accelerated MRI
Authors:
Tomer Weiss,
Sanketh Vedula,
Ortal Senouf,
Oleg Michailovich,
Michael Zibulevsky,
Alex Bronstein
Abstract:
Magnetic Resonance Imaging (MRI) is considered today the golden-standard modality for soft tissues. The long acquisition times, however, make it more prone to motion artifacts as well as contribute to the relatively high costs of this examination. Over the years, multiple studies concentrated on designing reduced measurement schemes and image reconstruction schemes for MRI, however, these problems…
▽ More
Magnetic Resonance Imaging (MRI) is considered today the golden-standard modality for soft tissues. The long acquisition times, however, make it more prone to motion artifacts as well as contribute to the relatively high costs of this examination. Over the years, multiple studies concentrated on designing reduced measurement schemes and image reconstruction schemes for MRI, however, these problems have been so far addressed separately. On the other hand, recent works in optical computational imaging have demonstrated growing success of the simultaneous learning-based design of the acquisition and reconstruction schemes manifesting significant improvement in the reconstruction quality with a constrained time budget. Inspired by these successes, in this work, we propose to learn accelerated MR acquisition schemes (in the form of Cartesian trajectories) jointly with the image reconstruction operator. To this end, we propose an algorithm for training the combined acquisition-reconstruction pipeline end-to-end in a differentiable way. We demonstrate the significance of using the learned Cartesian trajectories at different speed up rates.
△ Less
Submitted 5 April, 2020; v1 submitted 22 May, 2019;
originally announced May 2019.
-
Learning beamforming in ultrasound imaging
Authors:
Sanketh Vedula,
Ortal Senouf,
Grigoriy Zurakhov,
Alex Bronstein,
Oleg Michailovich,
Michael Zibulevsky
Abstract:
Medical ultrasound (US) is a widespread imaging modality owing its popularity to cost efficiency, portability, speed, and lack of harmful ionizing radiation. In this paper, we demonstrate that replacing the traditional ultrasound processing pipeline with a data-driven, learnable counterpart leads to significant improvement in image quality. Moreover, we demonstrate that greater improvement can be…
▽ More
Medical ultrasound (US) is a widespread imaging modality owing its popularity to cost efficiency, portability, speed, and lack of harmful ionizing radiation. In this paper, we demonstrate that replacing the traditional ultrasound processing pipeline with a data-driven, learnable counterpart leads to significant improvement in image quality. Moreover, we demonstrate that greater improvement can be achieved through a learning-based design of the transmitted beam patterns simultaneously with learning an image reconstruction pipeline. We evaluate our method on an in-vivo first-harmonic cardiac ultrasound dataset acquired from volunteers and demonstrate the significance of the learned pipeline and transmit beam patterns on the image quality when compared to standard transmit and receive beamformers used in high frame-rate US imaging. We believe that the presented methodology provides a fundamentally different perspective on the classical problem of ultrasound beam pattern design.
△ Less
Submitted 5 April, 2020; v1 submitted 19 December, 2018;
originally announced December 2018.
-
High frame-rate cardiac ultrasound imaging with deep learning
Authors:
Ortal Senouf,
Sanketh Vedula,
Grigoriy Zurakhov,
Alex M. Bronstein,
Michael Zibulevsky,
Oleg Michailovich,
Dan Adam,
David Blondheim
Abstract:
Cardiac ultrasound imaging requires a high frame rate in order to capture rapid motion. This can be achieved by multi-line acquisition (MLA), where several narrow-focused received lines are obtained from each wide-focused transmitted line. This shortens the acquisition time at the expense of introducing block artifacts. In this paper, we propose a data-driven learning-based approach to improve the…
▽ More
Cardiac ultrasound imaging requires a high frame rate in order to capture rapid motion. This can be achieved by multi-line acquisition (MLA), where several narrow-focused received lines are obtained from each wide-focused transmitted line. This shortens the acquisition time at the expense of introducing block artifacts. In this paper, we propose a data-driven learning-based approach to improve the MLA image quality. We train an end-to-end convolutional neural network on pairs of real ultrasound cardiac data, acquired through MLA and the corresponding single-line acquisition (SLA). The network achieves a significant improvement in image quality for both $5-$ and $7-$line MLA resulting in a decorrelation measure similar to that of SLA while having the frame rate of MLA.
△ Less
Submitted 23 August, 2018;
originally announced August 2018.
-
High quality ultrasonic multi-line transmission through deep learning
Authors:
Sanketh Vedula,
Ortal Senouf,
Grigoriy Zurakhov,
Alex M. Bronstein,
Michael Zibulevsky,
Oleg Michailovich,
Dan Adam,
Diana Gaitini
Abstract:
Frame rate is a crucial consideration in cardiac ultrasound imaging and 3D sonography. Several methods have been proposed in the medical ultrasound literature aiming at accelerating the image acquisition. In this paper, we consider one such method called \textit{multi-line transmission} (MLT), in which several evenly separated focused beams are transmitted simultaneously. While MLT reduces the acq…
▽ More
Frame rate is a crucial consideration in cardiac ultrasound imaging and 3D sonography. Several methods have been proposed in the medical ultrasound literature aiming at accelerating the image acquisition. In this paper, we consider one such method called \textit{multi-line transmission} (MLT), in which several evenly separated focused beams are transmitted simultaneously. While MLT reduces the acquisition time, it comes at the expense of a heavy loss of contrast due to the interactions between the beams (cross-talk artifact). In this paper, we introduce a data-driven method to reduce the artifacts arising in MLT. To this end, we propose to train an end-to-end convolutional neural network consisting of correction layers followed by a constant apodization layer. The network is trained on pairs of raw data obtained through MLT and the corresponding \textit{single-line transmission} (SLT) data. Experimental evaluation demonstrates significant improvement both in the visual image quality and in objective measures such as contrast ratio and contrast-to-noise ratio, while preserving resolution unlike traditional apodization-based methods. We show that the proposed method is able to generalize well across different patients and anatomies on real and phantom data.
△ Less
Submitted 23 August, 2018;
originally announced August 2018.
-
Towards CT-quality Ultrasound Imaging using Deep Learning
Authors:
Sanketh Vedula,
Ortal Senouf,
Alex M. Bronstein,
Oleg V. Michailovich,
Michael Zibulevsky
Abstract:
The cost-effectiveness and practical harmlessness of ultrasound imaging have made it one of the most widespread tools for medical diagnosis. Unfortunately, the beam-forming based image formation produces granular speckle noise, blurring, shading and other artifacts. To overcome these effects, the ultimate goal would be to reconstruct the tissue acoustic properties by solving a full wave propagatio…
▽ More
The cost-effectiveness and practical harmlessness of ultrasound imaging have made it one of the most widespread tools for medical diagnosis. Unfortunately, the beam-forming based image formation produces granular speckle noise, blurring, shading and other artifacts. To overcome these effects, the ultimate goal would be to reconstruct the tissue acoustic properties by solving a full wave propagation inverse problem. In this work, we make a step towards this goal, using Multi-Resolution Convolutional Neural Networks (CNN). As a result, we are able to reconstruct CT-quality images from the reflected ultrasound radio-frequency(RF) data obtained by simulation from real CT scans of a human body. We also show that CNN is able to imitate existing computationally heavy despeckling methods, thereby saving orders of magnitude in computations and making them amenable to real-time applications.
△ Less
Submitted 17 October, 2017;
originally announced October 2017.
-
Spatially regularized reconstruction of fibre orientation distributions in the presence of isotropic diffusion
Authors:
Q. Zhou,
O. Michailovich,
Y. Rathi
Abstract:
The connectivity and structural integrity of the white matter of the brain is nowadays known to be implicated into a wide range of brain-related disorders. However, it was not before the advent of diffusion Magnetic Resonance Imaging (dMRI) that researches have been able to examine the properties of white matter in vivo. Presently, among a range of various methods of dMRI, high angular resolution…
▽ More
The connectivity and structural integrity of the white matter of the brain is nowadays known to be implicated into a wide range of brain-related disorders. However, it was not before the advent of diffusion Magnetic Resonance Imaging (dMRI) that researches have been able to examine the properties of white matter in vivo. Presently, among a range of various methods of dMRI, high angular resolution diffusion imaging (HARDI) is known to excel in its ability to provide reliable information about the local orientations of neural fasciculi (aka fibre tracts). Moreover, as opposed to the more traditional diffusion tensor imaging (DTI), HARDI is capable of distinguishing the orientations of multiple fibres passing through a given spatial voxel. Unfortunately, the ability of HARDI to discriminate between neural fibres that cross each other at acute angles is always limited, which is the main reason behind the development of numerous post-processing tools, aiming at the improvement of the directional resolution of HARDI. Among such tools is spherical deconvolution (SD). Due to its ill-posed nature, however, SD standardly relies on a number of a priori assumptions which are to render its results unique and stable. In this paper, we propose a different approach to the problem of SD in HARDI, which accounts for the spatial continuity of neural fibres as well as the presence of isotropic diffusion. Subsequently, we demonstrate how the proposed solution can be used to successfully overcome the effect of partial voluming, while preserving the spatial coherency of cerebral diffusion at moderate-to-severe noise levels. In a series of both in silico and in vivo experiments, the performance of the proposed method is compared with that of several available alternatives, with the comparative results clearly supporting the viability and usefulness of our approach.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
A New Similarity Measure for Non-Local Means Filtering of MRI Images
Authors:
Sudipto Dolui,
Alan Kuurstra,
Iván C. Salgado Patarroyo,
Oleg V. Michailovich
Abstract:
The acquisition of MRI images offers a trade-off in terms of acquisition time, spatial/temporal resolution and signal-to-noise ratio (SNR). Thus, for instance, increasing the time efficiency of MRI often comes at the expense of reduced SNR. This, in turn, necessitates the use of post-processing tools for noise rejection, which makes image de-noising an indispensable component of computer assistanc…
▽ More
The acquisition of MRI images offers a trade-off in terms of acquisition time, spatial/temporal resolution and signal-to-noise ratio (SNR). Thus, for instance, increasing the time efficiency of MRI often comes at the expense of reduced SNR. This, in turn, necessitates the use of post-processing tools for noise rejection, which makes image de-noising an indispensable component of computer assistance diagnosis. In the field of MRI, a multitude of image de-noising methods have been proposed hitherto. In this paper, the application of a particular class of de-noising algorithms - known as non-local mean (NLM) filters - is investigated. Such filters have been recently applied for MRI data enhancement and they have been shown to provide more accurate results as compared to many alternative de-noising algorithms. Unfortunately, virtually all existing methods for NLM filtering have been derived under the assumption of additive white Gaussian (AWG) noise contamination. Since this assumption is known to fail at low values of SNR, an alternative formulation of NLM filtering is required, which would take into consideration the correct Rician statistics of MRI noise. Accordingly, the contribution of the present paper is two-fold. First, it points out some principal disadvantages of the earlier methods of NLM filtering of MRI images and suggests means to rectify them. Second, the paper introduces a new similarity measure for NLM filtering of MRI Images, which is derived under bona fide statistical assumptions and results in more accurate reconstruction of MR scans as compared to alternative NLM approaches. Finally, the utility and viability of the proposed method is demonstrated through a series of numerical experiments using both in silico and in vivo MRI data.
△ Less
Submitted 26 October, 2011;
originally announced October 2011.
-
Spatially regularized compressed sensing of diffusion MRI data
Authors:
Oleg Michailovich,
Yogesh Rathi,
Sudipto Dolui
Abstract:
The present paper introduces a method for substantial reduction of the number of diffusion encoding gradients required for reliable reconstruction of HARDI signals. The method exploits the theory of compressed sensing (CS), which establishes conditions on which a signal of interest can be recovered from its under-sampled measurements, provided that the signal admits a sparse representation in the…
▽ More
The present paper introduces a method for substantial reduction of the number of diffusion encoding gradients required for reliable reconstruction of HARDI signals. The method exploits the theory of compressed sensing (CS), which establishes conditions on which a signal of interest can be recovered from its under-sampled measurements, provided that the signal admits a sparse representation in the domain of a linear transform. In the case at hand, the latter is defined to be spherical ridgelet transformation, which excels in sparsifying HARDI signals. What makes the resulting reconstruction procedure even more accurate is a combination of the sparsity constraints in the diffusion domain with additional constraints imposed on the estimated diffusion field in the spatial domain. Accordingly, the present paper describes a novel way to combine the diffusion- and spatial-domain constraints to achieve a maximal reduction in the number of diffusion measurements, while sacrificing little in terms of reconstruction accuracy. Finally, details are provided on a particularly efficient numerical scheme which can be used to solve the aforementioned reconstruction problem by means of standard and readily available estimation tools. The paper is concluded with experimental results which support the practical value of the proposed reconstruction methodology.
△ Less
Submitted 18 September, 2010; v1 submitted 9 September, 2010;
originally announced September 2010.
-
Image Segmentation Using Weak Shape Priors
Authors:
Robert Sheng Xu,
Oleg Michailovich,
Magdy Salama
Abstract:
The problem of image segmentation is known to become particularly challenging in the case of partial occlusion of the object(s) of interest, background clutter, and the presence of strong noise. To overcome this problem, the present paper introduces a novel approach segmentation through the use of "weak" shape priors. Specifically, in the proposed method, an segmenting active contour is constraine…
▽ More
The problem of image segmentation is known to become particularly challenging in the case of partial occlusion of the object(s) of interest, background clutter, and the presence of strong noise. To overcome this problem, the present paper introduces a novel approach segmentation through the use of "weak" shape priors. Specifically, in the proposed method, an segmenting active contour is constrained to converge to a configuration at which its geometric parameters attain their empirical probability densities closely matching the corresponding model densities that are learned based on training samples. It is shown through numerical experiments that the proposed shape modeling can be regarded as "weak" in the sense that it minimally influences the segmentation, which is allowed to be dominated by data-related forces. On the other hand, the priors provide sufficient constraints to regularize the convergence of segmentation, while requiring substantially smaller training sets to yield less biased results as compared to the case of PCA-based regularization methods. The main advantages of the proposed technique over some existing alternatives is demonstrated in a series of experiments.
△ Less
Submitted 14 June, 2010;
originally announced June 2010.
-
Regularized Richardson-Lucy Algorithm for Sparse Reconstruction of Poissonian Images
Authors:
Elad Shaked,
Oleg Michailovich
Abstract:
Restoration of digital images from their degraded measurements has always been a problem of great theoretical and practical importance in numerous applications of imaging sciences. A specific solution to the problem of image restoration is generally determined by the nature of degradation phenomenon as well as by the statistical properties of measurement noises. The present study is concerned with…
▽ More
Restoration of digital images from their degraded measurements has always been a problem of great theoretical and practical importance in numerous applications of imaging sciences. A specific solution to the problem of image restoration is generally determined by the nature of degradation phenomenon as well as by the statistical properties of measurement noises. The present study is concerned with the case in which the images of interest are corrupted by convolutional blurs and Poisson noises. To deal with such problems, there exists a range of solution methods which are based on the principles originating from the fixed-point algorithm of Richardson and Lucy (RL). In this paper, we provide conceptual and experimental proof that such methods tend to converge to sparse solutions, which makes them applicable only to those images which can be represented by a relatively small number of non-zero samples in the spatial domain. Unfortunately, the set of such images is relatively small, which restricts the applicability of RL-type methods. On the other hand, virtually all practical images admit sparse representations in the domain of a properly designed linear transform. To take advantage of this fact, it is therefore tempting to modify the RL algorithm so as to make it recover representation coefficients, rather than the values of their associated image. Such modification is introduced in this paper. Apart from the generality of its assumptions, the proposed method is also superior to many established reconstruction approaches in terms of estimation accuracy and computational complexity. This and other conclusions of this study are validated through a series of numerical experiments.
△ Less
Submitted 7 April, 2010;
originally announced April 2010.
-
An Iterative Shrinkage Approach to Total-Variation Image Restoration
Authors:
Oleg Michailovich
Abstract:
The problem of restoration of digital images from their degraded measurements plays a central role in a multitude of practically important applications. A particularly challenging instance of this problem occurs in the case when the degradation phenomenon is modeled by an ill-conditioned operator. In such a case, the presence of noise makes it impossible to recover a valuable approximation of th…
▽ More
The problem of restoration of digital images from their degraded measurements plays a central role in a multitude of practically important applications. A particularly challenging instance of this problem occurs in the case when the degradation phenomenon is modeled by an ill-conditioned operator. In such a case, the presence of noise makes it impossible to recover a valuable approximation of the image of interest without using some a priori information about its properties. Such a priori information is essential for image restoration, rendering it stable and robust to noise. Particularly, if the original image is known to be a piecewise smooth function, one of the standard priors used in this case is defined by the Rudin-Osher-Fatemi model, which results in total variation (TV) based image restoration. The current arsenal of algorithms for TV-based image restoration is vast. In the present paper, a different approach to the solution of the problem is proposed based on the method of iterative shrinkage (aka iterated thresholding). In the proposed method, the TV-based image restoration is performed through a recursive application of two simple procedures, viz. linear filtering and soft thresholding. Therefore, the method can be identified as belonging to the group of first-order algorithms which are efficient in dealing with images of relatively large sizes. Another valuable feature of the proposed method consists in its working directly with the TV functional, rather then with its smoothed versions. Moreover, the method provides a single solution for both isotropic and anisotropic definitions of the TV functional, thereby establishing a useful connection between the two formulae.
△ Less
Submitted 26 October, 2009;
originally announced October 2009.
-
Iterative Shrinkage Approach to Restoration of Optical Imagery
Authors:
E. Shaked,
O. Michailovich
Abstract:
The problem of reconstruction of digital images from their degraded measurements is regarded as a problem of central importance in various fields of engineering and imaging sciences. In such cases, the degradation is typically caused by the resolution limitations of an imaging device in use and/or by the destructive influence of measurement noise. Specifically, when the noise obeys a Poisson pro…
▽ More
The problem of reconstruction of digital images from their degraded measurements is regarded as a problem of central importance in various fields of engineering and imaging sciences. In such cases, the degradation is typically caused by the resolution limitations of an imaging device in use and/or by the destructive influence of measurement noise. Specifically, when the noise obeys a Poisson probability law, standard approaches to the problem of image reconstruction are based on using fixed-point algorithms which follow the methodology first proposed by Richardson and Lucy. The practice of using these methods, however, shows that their convergence properties tend to deteriorate at relatively high noise levels. Accordingly, in the present paper, a novel method for de-noising and/or de-blurring of digital images corrupted by Poisson noise is introduced. The proposed method is derived under the assumption that the image of interest can be sparsely represented in the domain of a linear transform. Consequently, a shrinkage-based iterative procedure is proposed, which guarantees the solution to converge to the global maximizer of an associated maximum-a-posteriori criterion. It is shown in a series of both computer-simulated and real-life experiments that the proposed method outperforms a number of existing alternatives in terms of stability, precision, and computational efficiency.
△ Less
Submitted 6 January, 2010; v1 submitted 29 September, 2009;
originally announced September 2009.
-
Information tracking approach to segmentation of ultrasound imagery of prostate
Authors:
Robert Sheng Xu,
Oleg Michailovich,
Magdy Salama
Abstract:
The size and geometry of the prostate are known to be pivotal quantities used by clinicians to assess the condition of the gland during prostate cancer screening. As an alternative to palpation, an increasing number of methods for estimation of the above-mentioned quantities are based on using imagery data of prostate. The necessity to process large volumes of such data creates a need for automa…
▽ More
The size and geometry of the prostate are known to be pivotal quantities used by clinicians to assess the condition of the gland during prostate cancer screening. As an alternative to palpation, an increasing number of methods for estimation of the above-mentioned quantities are based on using imagery data of prostate. The necessity to process large volumes of such data creates a need for automatic segmentation tools which would allow the estimation to be carried out with maximum accuracy and efficiency. In particular, the use of transrectal ultrasound (TRUS) imaging in prostate cancer screening seems to be becoming a standard clinical practice due to the high benefit-to-cost ratio of this imaging modality. Unfortunately, the segmentation of TRUS images is still hampered by relatively low contrast and reduced SNR of the images, thereby requiring the segmentation algorithms to incorporate prior knowledge about the geometry of the gland. In this paper, a novel approach to the problem of segmenting the TRUS images is described. The proposed approach is based on the concept of distribution tracking, which provides a unified framework for modeling and fusing image-related and morphological features of the prostate. Moreover, the same framework allows the segmentation to be regularized via using a new type of "weak" shape priors, which minimally bias the estimation procedure, while rendering the latter stable and robust.
△ Less
Submitted 29 September, 2009;
originally announced September 2009.