-
Tissue Cross-Section and Pen Marking Segmentation in Whole Slide Images
Authors:
Ruben T. Lucassen,
Willeke A. M. Blokx,
Mitko Veta
Abstract:
Tissue segmentation is a routine preprocessing step to reduce the computational cost of whole slide image (WSI) analysis by excluding background regions. Traditional image processing techniques are commonly used for tissue segmentation, but often require manual adjustments to parameter values for atypical cases, fail to exclude all slide and scanning artifacts from the background, and are unable t…
▽ More
Tissue segmentation is a routine preprocessing step to reduce the computational cost of whole slide image (WSI) analysis by excluding background regions. Traditional image processing techniques are commonly used for tissue segmentation, but often require manual adjustments to parameter values for atypical cases, fail to exclude all slide and scanning artifacts from the background, and are unable to segment adipose tissue. Pen marking artifacts in particular can be a potential source of bias for subsequent analyses if not removed. In addition, several applications require the separation of individual cross-sections, which can be challenging due to tissue fragmentation and adjacent positioning. To address these problems, we develop a convolutional neural network for tissue and pen marking segmentation using a dataset of 200 H&E stained WSIs. For separating tissue cross-sections, we propose a novel post-processing method based on clustering predicted centroid locations of the cross-sections in a 2D histogram. On an independent test set, the model achieved a mean Dice score of 0.981$\pm$0.033 for tissue segmentation and a mean Dice score of 0.912$\pm$0.090 for pen marking segmentation. The mean absolute difference between the number of annotated and separated cross-sections was 0.075$\pm$0.350. Our results demonstrate that the proposed model can accurately segment H&E stained tissue cross-sections and pen markings in WSIs while being robust to many common slide and scanning artifacts. The model with trained model parameters and post-processing method are made publicly available as a Python package called SlideSegmenter.
△ Less
Submitted 24 January, 2024;
originally announced January 2024.
-
Gamified Crowdsourcing as a Novel Approach to Lung Ultrasound Dataset Labeling
Authors:
Nicole M Duggan,
Mike **,
Maria Alejandra Duran Mendicuti,
Stephen Hallisey,
Denie Bernier,
Lauren A Selame,
Ameneh Asgari-Targhi,
Chanel E Fischetti,
Ruben Lucassen,
Anthony E Samir,
Erik Duhaime+,
Tina Kapur,
Andrew J Goldsmith
Abstract:
Study Objective: Machine learning models have advanced medical image processing and can yield faster, more accurate diagnoses. Despite a wealth of available medical imaging data, high-quality labeled data for model training is lacking. We investigated whether a gamified crowdsourcing platform enhanced with inbuilt quality control metrics can produce lung ultrasound clip labels comparable to those…
▽ More
Study Objective: Machine learning models have advanced medical image processing and can yield faster, more accurate diagnoses. Despite a wealth of available medical imaging data, high-quality labeled data for model training is lacking. We investigated whether a gamified crowdsourcing platform enhanced with inbuilt quality control metrics can produce lung ultrasound clip labels comparable to those from clinical experts.
Methods: 2,384 lung ultrasound clips were retrospectively collected from 203 patients. Six lung ultrasound experts classified 393 of these clips as having no B-lines, one or more discrete B-lines, or confluent B-lines to create two sets of reference standard labels (195 training set clips and 198 test set clips). Sets were respectively used to A) train users on a gamified crowdsourcing platform, and B) compare concordance of the resulting crowd labels to the concordance of individual experts to reference standards.
Results: 99,238 crowdsourced opinions on 2,384 lung ultrasound clips were collected from 426 unique users over 8 days. On the 198 test set clips, mean labeling concordance of individual experts relative to the reference standard was 85.0% +/- 2.0 (SEM), compared to 87.9% crowdsourced label concordance (p=0.15). When individual experts' opinions were compared to reference standard labels created by majority vote excluding their own opinion, crowd concordance was higher than the mean concordance of individual experts to reference standards (87.4% vs. 80.8% +/- 1.6; p<0.001).
Conclusion: Crowdsourced labels for B-line classification via a gamified approach achieved expert-level quality. Scalable, high-quality labeling approaches may facilitate training dataset creation for machine learning model development.
△ Less
Submitted 11 June, 2023;
originally announced June 2023.
-
Corneal Pachymetry by AS-OCT after Descemet's Membrane Endothelial Keratoplasty
Authors:
Friso G. Heslinga,
Ruben T. Lucassen,
Myrthe A. van den Berg,
Luuk van der Hoek,
Josien P. W. Pluim,
Javier Cabrerizo,
Mark Alberti,
Mitko Veta
Abstract:
Corneal thickness (pachymetry) maps can be used to monitor restoration of corneal endothelial function, for example after Descemet's membrane endothelial keratoplasty (DMEK). Automated delineation of the corneal interfaces in anterior segment optical coherence tomography (AS-OCT) can be challenging for corneas that are irregularly shaped due to pathology, or as a consequence of surgery, leading to…
▽ More
Corneal thickness (pachymetry) maps can be used to monitor restoration of corneal endothelial function, for example after Descemet's membrane endothelial keratoplasty (DMEK). Automated delineation of the corneal interfaces in anterior segment optical coherence tomography (AS-OCT) can be challenging for corneas that are irregularly shaped due to pathology, or as a consequence of surgery, leading to incorrect thickness measurements. In this research, deep learning is used to automatically delineate the corneal interfaces and measure corneal thickness with high accuracy in post-DMEK AS-OCT B-scans. Three different deep learning strategies were developed based on 960 B-scans from 50 patients. On an independent test set of 320 B-scans, corneal thickness could be measured with an error of 13.98 to 15.50 micrometer for the central 9 mm range, which is less than 3% of the average corneal thickness. The accurate thickness measurements were used to construct detailed pachymetry maps. Moreover, follow-up scans could be registered based on anatomical landmarks to obtain differential pachymetry maps. These maps may enable a more comprehensive understanding of the restoration of the endothelial function after DMEK, where thickness often varies throughout different regions of the cornea, and subsequently contribute to a standardized postoperative regime.
△ Less
Submitted 6 April, 2021; v1 submitted 15 February, 2021;
originally announced February 2021.