Resilient Energy Efficient Healthcare Monitoring Infrastructure with Server and Network Protection
Authors:
Ida Syafiza M. Isa,
Taisir E. H. El-Gorashi,
Mohamed O. I. Musa,
J. M. H. Elmirghani
Abstract:
In this paper, a 1+1 server protection scheme is considered where two servers, a primary and a secondary processing server are used to serve ECG monitoring applications concurrently. The infrastructure is designed to be resilient against server failure under two scenarios related to the geographic location of primary and secondary servers and resilient against both server and network failures. A M…
▽ More
In this paper, a 1+1 server protection scheme is considered where two servers, a primary and a secondary processing server are used to serve ECG monitoring applications concurrently. The infrastructure is designed to be resilient against server failure under two scenarios related to the geographic location of primary and secondary servers and resilient against both server and network failures. A Mixed Integer Linear Programming (MILP) model is used to optimise the number and locations of both primary and secondary processing servers so that the energy consumption of the networking equipment and processing are minimised. The results show that considering a scenario for server protection without geographical constraints compared to the non-resilient scenario has resulted in both network and processing energy penalty as the traffic is doubled. The results also reveal that increasing the level of resilience to consider geographical constraints compared to case without geographical constraints resulted in higher network energy penalty when the demand is low as more nodes are utilised to place the processing servers under the geographic constraints. Also, increasing the level of resilience to consider network protection with link and node disjoint selection has resulted in a low network energy penalty at high demands due to the activation of a large part of the network in any case due to the demands. However, the results show that the network energy penalty is reduced with the increasing number of processing servers at each candidate node. Meanwhile, the same energy for processing is consumed regardless of the increasing level of resilience as the same number of processing servers are utilised. A heuristic is developed for each resilience scenario for real-time implementation where the results show that the performance of the heuristic is approaching the results of the MILP model.
△ Less
Submitted 28 October, 2020;
originally announced October 2020.
-
Energy Efficient Fog based Healthcare Monitoring Infrastructure
Authors:
Ida Syafiza M. Isa,
Taisir E. H. El-Gorashi,
Mohamed O. I. Musa,
Jaafar M. H. Elmirghani
Abstract:
Recent advances in mobile technologies and cloud computing services have inspired the development of cloud-based real-time health monitoring systems. However, the transfer of health-related data to the cloud contributes to the burden on the networking infrastructures, leading to high latency and increased power consumption. Fog computing is introduced to relieve this burden by bringing services to…
▽ More
Recent advances in mobile technologies and cloud computing services have inspired the development of cloud-based real-time health monitoring systems. However, the transfer of health-related data to the cloud contributes to the burden on the networking infrastructures, leading to high latency and increased power consumption. Fog computing is introduced to relieve this burden by bringing services to the users proximity. This study proposes a new fog computing architecture for health monitoring applications based on a Gigabit Passive Optical Network (GPON) access network. An Energy-Efficient Fog Computing (EEFC) model is developed using Mixed Integer Linear Programming (MILP) to optimize the number and location of fog devices at the network edge to process and analyze the health data for energy-efficient fog computing. The performance of the EEFC model at low data rates and high data rates health applications is studied. The outcome of the study reveals that a total energy saving of 36% and 52% are attained via processing and analysis the health data at the fog in comparison to conventional processing and analysis at the central cloud for low data rate application and high data rate application, respectively. We also developed a real-time heuristic; Energy Optimized Fog Computing (EOFC) heuristic, with energy consumption performance approaching the EEFC model. Furthermore, we examined the energy efficiency improvements under different scenarios of devices idle power consumption and traffic volume.
△ Less
Submitted 27 July, 2020;
originally announced July 2020.
-
Energy Efficient and Resilient Infrastructure for Fog Computing Health Monitoring Applications
Authors:
Ida Syafiza M. Isa,
Mohamed O. I. Musa,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, we propose a resilient energy efficient and fog computing infrastructure for health monitoring applications. We design the infrastructure to be resilient against server failures under two scenarios; without geographical constraints and with geographical constraints. We consider a heart monitoring application where patients send their 30-seconds recording of Electrocardiogram (ECG) s…
▽ More
In this paper, we propose a resilient energy efficient and fog computing infrastructure for health monitoring applications. We design the infrastructure to be resilient against server failures under two scenarios; without geographical constraints and with geographical constraints. We consider a heart monitoring application where patients send their 30-seconds recording of Electrocardiogram (ECG) signal for processing, analysis and decision making at both primary and backup servers. A Mixed Integer Linear Programming (MILP) model is used to optimize the number and locations of the primary and backup processing servers so that the energy consumption of both the processing and networking equipment are minimized. The results show that considering geographical constraints yields a network energy consumption increase by up to 9% compared to without geographical constraint. The results also show that, increasing the number of processing servers that can be served at each candidate node can reduce the energy consumption of networking equipment besides reducing the rate of energy increase of networking equipment due to increasing level of demand.
△ Less
Submitted 2 April, 2019;
originally announced April 2019.
-
Energy Efficiency of Fog Computing Health Monitoring Applications
Authors:
Ida Syafiza M. Isa,
Mohamed O. I. Musa,
Taisir E. H. El-Gorashi,
Ahmed Q. Lawey,
Jaafar M. H. Elmirghani
Abstract:
Fog computing offers a scalable and effective solution to overcome the increasing processing and networking demands of Internet of Thing (IoT) devices. In this paper, we investigate the use of fog computing for health monitoring applications. We consider a heart monitoring application where patients send their 30 minute recording of Electrocardiogram (ECG) signal for processing, analysis, and deci…
▽ More
Fog computing offers a scalable and effective solution to overcome the increasing processing and networking demands of Internet of Thing (IoT) devices. In this paper, we investigate the use of fog computing for health monitoring applications. We consider a heart monitoring application where patients send their 30 minute recording of Electrocardiogram (ECG) signal for processing, analysis, and decision making at fog processing units within the time constraint recommended by the American Heart Association (AHA) to save heart patients when an abnormality in the ECG signal is detected. The locations of the processing servers are optimized so that the energy consumption of both the processing and networking equipment are minimised. The results show that processing the ECG signal at fog processing units yields a total energy consumption saving of up to 68% compared to processing the at the central cloud.
△ Less
Submitted 18 August, 2018;
originally announced August 2018.