-
Calibration and evaluation of a motion measurement system for PET imaging studies
Authors:
Junxiang Wang,
Ti Wu,
Iulian I. Iordachita,
Peter Kazanzides
Abstract:
Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution is to construct a robotic system that can support an imaging system surrounding the subject's head, and then move the system to accommodate natural motion. This…
▽ More
Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution is to construct a robotic system that can support an imaging system surrounding the subject's head, and then move the system to accommodate natural motion. This requires a system to measure the motion of the head with respect to the imaging ring, for use by both the robotic system and the image reconstruction software. We report here the design, calibration, and experimental evaluation of a parallel string encoder mechanism for sensing this motion. Our results indicate that with kinematic calibration, the measurement system can achieve accuracy within 0.5mm, especially for small motions.
△ Less
Submitted 29 November, 2023;
originally announced November 2023.
-
Evaluation of a motion measurement system for PET imaging studies
Authors:
Junxiang Wang,
Ti Wu,
Iulian I. Iordachita,
Peter Kazanzides
Abstract:
Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution is to construct a robotic system that can support an imaging system surrounding the subject's head, and then move the system to accommodate natural motion. This…
▽ More
Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution is to construct a robotic system that can support an imaging system surrounding the subject's head, and then move the system to accommodate natural motion. This requires a system to measure the motion of the head with respect to the imaging ring, for use by both the robotic system and the image reconstruction software. We report here the design and experimental evaluation of a parallel string encoder mechanism for sensing this motion. Our preliminary results indicate that the measurement system may achieve accuracy within 0.5 mm, especially for small motions, with improved accuracy possible through kinematic calibration.
△ Less
Submitted 5 December, 2023; v1 submitted 29 November, 2023;
originally announced November 2023.
-
Method for robotic motion compensation during PET imaging of mobile subjects
Authors:
Junxiang Wang,
Iulian I. Iordachita,
Peter Kazanzides
Abstract:
Studies of the human brain during natural activities, such as locomotion, would benefit from the ability to image deep brain structures during these activities. While Positron Emission Tomography (PET) can image these structures, the bulk and weight of current scanners are not compatible with the desire for a wearable device. This has motivated the design of a robotic system to support a PET imagi…
▽ More
Studies of the human brain during natural activities, such as locomotion, would benefit from the ability to image deep brain structures during these activities. While Positron Emission Tomography (PET) can image these structures, the bulk and weight of current scanners are not compatible with the desire for a wearable device. This has motivated the design of a robotic system to support a PET imaging system around the subject's head and to move the system to accommodate natural motion. We report here the design and experimental evaluation of a prototype robotic system that senses motion of a subject's head, using parallel string encoders connected between the robot-supported imaging ring and a helmet worn by the subject. This measurement is used to robotically move the imaging ring (coarse motion correction) and to compensate for residual motion during image reconstruction (fine motion correction). Minimization of latency and measurement error are the key design goals, respectively, for coarse and fine motion correction. The system is evaluated using recorded human head motions during locomotion, with a mock imaging system consisting of lasers and cameras, and is shown to provide an overall system latency of about 80 ms, which is sufficient for coarse motion correction and collision avoidance, as well as a measurement accuracy of about 0.5 mm for fine motion correction.
△ Less
Submitted 29 November, 2023;
originally announced November 2023.
-
Haptic-Enhanced Virtual Reality Simulator for Robot-Assisted Femur Fracture Surgery
Authors:
Fayez H. Alruwaili,
David W. Halim-Banoub,
Jessica Rodgers,
Adam Dalkilic,
Christopher Haydel,
Javad Parvizi,
Iulian I. Iordachita,
Mohammad H. Abedin-Nasab
Abstract:
In this paper, we develop a virtual reality (VR) simulator for the Robossis robot-assisted femur fracture surgery. Due to the steep learning curve for such procedures, a VR simulator is essential for training surgeon(s) and staff. The Robossis Surgical Simulator (RSS) is designed to immerse user(s) in a realistic surgery setting using the Robossis system as completed in a previous real-world cadav…
▽ More
In this paper, we develop a virtual reality (VR) simulator for the Robossis robot-assisted femur fracture surgery. Due to the steep learning curve for such procedures, a VR simulator is essential for training surgeon(s) and staff. The Robossis Surgical Simulator (RSS) is designed to immerse user(s) in a realistic surgery setting using the Robossis system as completed in a previous real-world cadaveric procedure. The RSS is designed to interface the Sigma-7 Haptic Controller with the Robossis Surgical Robot (RSR) and the Meta Quest VR headset. Results show that the RSR follows user commands in 6 DOF and prevents the overlap** of bone segments. This development demonstrates a promising avenue for future implementation of the Robossis system.
△ Less
Submitted 29 October, 2023;
originally announced October 2023.
-
Design and Experimental Evaluation of a Haptic Robot-Assisted System for Femur Fracture Surgery
Authors:
Fayez H. Alruwaili,
Michael P. Clancy,
Marzieh S. Saeedi-Hosseiny,
Jacob A. Logar,
Charalampos Papachristou,
Christopher Haydel,
Javad Parvizi,
Iulian I. Iordachita,
Mohammad H. Abedin-Nasab
Abstract:
In the face of challenges encountered during femur fracture surgery, such as the high rates of malalignment and X-ray exposure to operating personnel, robot-assisted surgery has emerged as an alternative to conventional state-of-the-art surgical methods. This paper introduces the development of Robossis, a haptic system for robot-assisted femur fracture surgery. Robossis comprises a 7-DOF haptic c…
▽ More
In the face of challenges encountered during femur fracture surgery, such as the high rates of malalignment and X-ray exposure to operating personnel, robot-assisted surgery has emerged as an alternative to conventional state-of-the-art surgical methods. This paper introduces the development of Robossis, a haptic system for robot-assisted femur fracture surgery. Robossis comprises a 7-DOF haptic controller and a 6-DOF surgical robot. A unilateral control architecture is developed to address the kinematic mismatch and the motion transfer between the haptic controller and the Robossis surgical robot. A real-time motion control pipeline is designed to address the motion transfer and evaluated through experimental testing. The analysis illustrates that the Robossis surgical robot can adhere to the desired trajectory from the haptic controller with an average translational error of 0.32 mm and a rotational error of 0.07 deg. Additionally, a haptic rendering pipeline is developed to resolve the kinematic mismatch by constraining the haptic controller (user hand) movement within the permissible joint limits of the Robossis surgical robot. Lastly, in a cadaveric lab test, the Robossis system assisted surgeons during a mock femur fracture surgery. The result shows that Robossis can provide an intuitive solution for surgeons to perform femur fracture surgery.
△ Less
Submitted 29 October, 2023;
originally announced October 2023.
-
Optical Fiber-Based Needle Shape Sensing in Real Tissue: Single Core vs. Multicore Approaches
Authors:
Dimitri A. Lezcano,
Yernar Zhetpissov,
Alexandra Cheng,
** Seob Kim,
Iulian I. Iordachita
Abstract:
Flexible needle insertion procedures are common for minimally-invasive surgeries for diagnosing and treating prostate cancer. Bevel-tip needles provide physicians the capability to steer the needle during long insertions to avoid vital anatomical structures in the patient and reduce post-operative patient discomfort. To provide needle placement feedback to the physician, sensors are embedded into…
▽ More
Flexible needle insertion procedures are common for minimally-invasive surgeries for diagnosing and treating prostate cancer. Bevel-tip needles provide physicians the capability to steer the needle during long insertions to avoid vital anatomical structures in the patient and reduce post-operative patient discomfort. To provide needle placement feedback to the physician, sensors are embedded into needles for determining the real-time 3D shape of the needle during operation without needing to visualize the needle intra-operatively. Through expansive research in fiber optics, a plethora of bio-compatible, MRI-compatible, optical shape-sensors have been developed to provide real-time shape feedback, such as single-core and multicore fiber Bragg gratings. In this paper, we directly compare single-core fiber-based and multicore fiber-based needle shape-sensing through identically constructed, four-active area sensorized bevel-tip needles inserted into phantom and \exvivo tissue on the same experimental platform. In this work, we found that for shape-sensing in phantom tissue, the two needles performed identically with a $p$-value of $0.164 > 0.05$, but in \exvivo real tissue, the single-core fiber sensorized needle significantly outperformed the multicore fiber configuration with a $p$-value of $0.0005 < 0.05$. This paper also presents the experimental platform and method for directly comparing these optical shape sensors for the needle shape-sensing task, as well as provides direction, insight and required considerations for future work in constructively optimizing sensorized needles.
△ Less
Submitted 8 September, 2023;
originally announced September 2023.
-
Multi-Contact Force-Sensing Guitar for Training and Therapy
Authors:
Zhiyi Ren,
Chun-Cheng Hsu,
Can Kocabalkanli,
Khanh Nguyen,
Iulian I. Iordachita,
Serap Bastepe-Gray,
Nathan Scott
Abstract:
Hand injuries from repetitive high-strain and physical overload can hamper or even end a musician's career. To help musicians develop safer playing habits, we developed a multiplecontact force-sensing array that can substitute as a guitar fretboard. The system consists of 72 individual force sensing modules, each containing a flexure and a photointerrupter that measures the corresponding deflectio…
▽ More
Hand injuries from repetitive high-strain and physical overload can hamper or even end a musician's career. To help musicians develop safer playing habits, we developed a multiplecontact force-sensing array that can substitute as a guitar fretboard. The system consists of 72 individual force sensing modules, each containing a flexure and a photointerrupter that measures the corresponding deflection when forces are applied. The system is capable of measuring forces between 0-25 N applied anywhere within the first 12 frets at a rate of 20 Hz with an average accuracy of 0.4 N and a resolution of 0.1 N. Accompanied with a GUI, the resulting prototype was received positively as a useful tool for learning and injury prevention by novice and expert musicians.
△ Less
Submitted 25 February, 2023;
originally announced April 2023.
-
Spotlight-based 3D Instrument Guidance for Retinal Surgery
Authors:
Mingchuan Zhou,
Jiahao Wu,
Ali Ebrahimi,
Niravkumar Patel,
Changyan He,
Peter Gehlbach,
Russell H Taylor,
Alois Knoll,
M Ali Nasseri,
Iulian I Iordachita
Abstract:
Retinal surgery is a complex activity that can be challenging for a surgeon to perform effectively and safely. Image guided robot-assisted surgery is one of the promising solutions that bring significant surgical enhancement in treatment outcome and reduce the physical limitations of human surgeons. In this paper, we demonstrate a novel method for 3D guidance of the instrument based on the project…
▽ More
Retinal surgery is a complex activity that can be challenging for a surgeon to perform effectively and safely. Image guided robot-assisted surgery is one of the promising solutions that bring significant surgical enhancement in treatment outcome and reduce the physical limitations of human surgeons. In this paper, we demonstrate a novel method for 3D guidance of the instrument based on the projection of spotlight in the single microscope images. The spotlight projection mechanism is firstly analyzed and modeled with a projection on both a plane and a sphere surface. To test the feasibility of the proposed method, a light fiber is integrated into the instrument which is driven by the Steady-Hand Eye Robot (SHER). The spot of light is segmented and tracked on a phantom retina using the proposed algorithm. The static calibration and dynamic test results both show that the proposed method can easily archive 0.5 mm of tip-to-surface distance which is within the clinically acceptable accuracy for intraocular visual guidance.
△ Less
Submitted 11 December, 2020;
originally announced December 2020.