Skip to main content

Showing 1–5 of 5 results for author: Hegeman, R

Searching in archive cs. Search in all archives.
.
  1. Automatic Annotation of Hip Anatomy in Fluoroscopy for Robust and Efficient 2D/3D Registration

    Authors: Robert Grupp, Mathias Unberath, Cong Gao, Rachel Hegeman, Ryan Murphy, Clayton Alexander, Yoshito Otake, Benjamin McArthur, Mehran Armand, Russell Taylor

    Abstract: Fluoroscopy is the standard imaging modality used to guide hip surgery and is therefore a natural sensor for computer-assisted navigation. In order to efficiently solve the complex registration problems presented during navigation, human-assisted annotations of the intraoperative image are typically required. This manual initialization interferes with the surgical workflow and diminishes any advan… ▽ More

    Submitted 18 March, 2020; v1 submitted 16 November, 2019; originally announced November 2019.

    Comments: Revised article to address reviewer comments. Accepted to IPCAI 2020. Supplementary video at https://youtu.be/5AwGlNkcp9o and dataset/code at https://github.com/rg2/DeepFluoroLabeling-IPCAI2020

    Journal ref: International Journal of Computer Assisted Radiology and Surgery 15 (2020) 759-769

  2. Fast and Automatic Periacetabular Osteotomy Fragment Pose Estimation Using Intraoperatively Implanted Fiducials and Single-View Fluoroscopy

    Authors: Robert Grupp, Ryan Murphy, Rachel Hegeman, Clayton Alexander, Mathias Unberath, Yoshito Otake, Benjamin McArthur, Mehran Armand, Russell Taylor

    Abstract: Accurate and consistent mental interpretation of fluoroscopy to determine the position and orientation of acetabular bone fragments in 3D space is difficult. We propose a computer assisted approach that uses a single fluoroscopic view and quickly reports the pose of an acetabular fragment without any user input or initialization. Intraoperatively, but prior to any osteotomies, two constellations o… ▽ More

    Submitted 12 June, 2020; v1 submitted 22 October, 2019; originally announced October 2019.

    Comments: Revised article to address reviewer comments. Under review for Physics in Medicine and Biology. Supplementary video at https://youtu.be/0E0U9G81q8g

    Journal ref: 2020 Phys. Med. Biol. 65 245019

  3. Pose Estimation of Periacetabular Osteotomy Fragments with Intraoperative X-Ray Navigation

    Authors: Robert B. Grupp, Rachel A. Hegeman, Ryan J. Murphy, Clayton P. Alexander, Yoshito Otake, Benjamin A. McArthur, Mehran Armand, Russell H. Taylor

    Abstract: Objective: State of the art navigation systems for pelvic osteotomies use optical systems with external fiducials. We propose the use of X-Ray navigation for pose estimation of periacetabular fragments without fiducials. Methods: A 2D/3D registration pipeline was developed to recover fragment pose. This pipeline was tested through an extensive simulation study and 6 cadaveric surgeries. Using oste… ▽ More

    Submitted 9 May, 2019; v1 submitted 21 March, 2019; originally announced March 2019.

    Comments: Accepted for publication in IEEE Transactions on Biomedical Engineering

    Journal ref: IEEE Transactions on Biomedical Engineering, vol. 67, no. 2, pp. 441-452, Feb. 2020

  4. arXiv:1812.08629  [pdf, other

    cs.RO

    FBG-Based Position Estimation of Highly Deformable Continuum Manipulators: Model-Dependent vs. Data-Driven Approaches

    Authors: Shahriar Sefati, Rachel Hegeman, Farshid Alambeigi, Iulian Iordachita, Mehran Armand

    Abstract: Conventional shape sensing techniques using Fiber Bragg Grating (FBG) involve finding the curvature at discrete FBG active areas and integrating curvature over the length of the continuum dexterous manipulator (CDM) for tip position estimation (TPE). However, due to limited number of sensing locations and many geometrical assumptions, these methods are prone to large error propagation especially w… ▽ More

    Submitted 20 December, 2018; originally announced December 2018.

    Comments: Accepted for International Symposium on Medical Robotics (ISMR) 2019

  5. arXiv:1807.00224  [pdf

    cs.RO

    Inroads Toward Robot-Assisted Internal Fixation of Bone Fractures Using a Bendable Medical Screw and the Curved Drilling Technique

    Authors: Farshid Alambeigi, Mahsan Bakhtiarinejad, Armina Azizi, Rachel Hegeman, Iulian Iordachita, Harpal Khanuja, Mehran Armand

    Abstract: Internal fixation is a common orthopedic procedure in which a rigid screw is used to fix fragments of a fractured bone together and expedite the healing process. However, the rigidity of the screw, geometry of the fractured anatomy (e.g. femur and pelvis), and patient age can cause an array of complications during screw placement, such as improper fracture healing due to misalignment of the bone f… ▽ More

    Submitted 30 June, 2018; originally announced July 2018.

    Comments: 6 pages, To be appeared in the 7th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (BIOROB 2018)