-
Energy Efficient Service Placement for IoT Networks
Authors:
Mohammed A. Alshahrani,
Ahmad Adnan Qidan,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
In recent years, there has been a significant expansion in the Internet of Things (IoT), with a growing number of devices being connected to the internet. This has led to an increase in data collection and analysis as well as the development of new technologies and applications. The rise of IoT has also brought about new challenges, such as security concerns and energy efficiency. This study inves…
▽ More
In recent years, there has been a significant expansion in the Internet of Things (IoT), with a growing number of devices being connected to the internet. This has led to an increase in data collection and analysis as well as the development of new technologies and applications. The rise of IoT has also brought about new challenges, such as security concerns and energy efficiency. This study investigates a layered IoT architecture that combines fog and cloud computing, aiming to assess the impact of service placement on energy efficiency. Through simulations, we analyse energy use across Access Fog, Metro Fog, and Cloud Data Centre layers for different IoT request volumes. Findings indicate that Access Fog is optimal for single requests, while Metro Fog efficiently manages higher demands from multiple devices. The study emphasizes the need for adaptive service deployment, responsive to network load variations, to improve energy efficiency. Hence, we propose the implementation of dynamic service placement strategies within Internet of Things (IoT) environments.
△ Less
Submitted 25 April, 2024;
originally announced April 2024.
-
Access-Point to Access-Point Connectivity for PON-based OWC Spine and Leaf Data Centre Architecture
Authors:
Abrar S. Alhazmi,
Sanaa H. Mohamed,
Ahmad Qidan,
T. E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, we propose incorporating Optical Wireless Communication (OWC) and Passive Optical Network (PON) technologies into next generation spine-and-leaf Data Centre Networks (DCNs). In this work, OWC systems are used to connect the Data Centre (DC) racks through Wavelength Division Multiplexing (WDM) Infrared (IR) transceivers. The transceivers are placed on top of the racks and at distribu…
▽ More
In this paper, we propose incorporating Optical Wireless Communication (OWC) and Passive Optical Network (PON) technologies into next generation spine-and-leaf Data Centre Networks (DCNs). In this work, OWC systems are used to connect the Data Centre (DC) racks through Wavelength Division Multiplexing (WDM) Infrared (IR) transceivers. The transceivers are placed on top of the racks and at distributed Access Points (APs) in the ceiling. Each transceiver on a rack is connected to a leaf switch that connects the servers within the rack. We replace the spine switches by Optical Line Terminal (OLT) and Network Interface Cards (NIC) in the APs to achieve the desired connectivity. We benchmark the power consumption of the proposed OWC-PON-based spine-and-leaf DC against traditional spine-and-leaf DC and report 46% reduction in the power consumption when considering eight racks.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
WDM/TDM over Passive Optical Networks with Cascaded-AWGRs for Data Centers
Authors:
Mohammed Alharthi,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Data centers based on Passive Optical Networks (PONs) can provide high capacity, low cost, scalability, elasticity and high energy-efficiency. This paper introduces the use of WDM-TDM multiple access in a PON-based data center that offers multipath routing via two-tier cascaded Arrayed Waveguide Grating Routers (AWGRs) to improve the utilization of resources. A Mixed Integer Linear Programming (MI…
▽ More
Data centers based on Passive Optical Networks (PONs) can provide high capacity, low cost, scalability, elasticity and high energy-efficiency. This paper introduces the use of WDM-TDM multiple access in a PON-based data center that offers multipath routing via two-tier cascaded Arrayed Waveguide Grating Routers (AWGRs) to improve the utilization of resources. A Mixed Integer Linear Programming (MILP) model is developed to optimize resource allocation while considering multipath routing. The results show that all-to-all connectivity is achieved in the architecture through the use of two different wavelength within different time slots for the communication between racks in the same or different cells, as well as with the OLT switches.
△ Less
Submitted 30 May, 2023;
originally announced May 2023.
-
Energy Efficient Resource Allocation for Demand Intensive Applications in a VLC Based Fog Architecture
Authors:
Wafaa B. M. Fadlelmula,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, we propose an energy efficient passive optical network (PON) architecture for backhaul connectivity in indoor visible light communication (VLC) systems. The proposed network is used to support a fog computing architecture designed to allow users with processing demands to access dedicated fog nodes and idle processing resources in other user devices (UDs) within the same building. T…
▽ More
In this paper, we propose an energy efficient passive optical network (PON) architecture for backhaul connectivity in indoor visible light communication (VLC) systems. The proposed network is used to support a fog computing architecture designed to allow users with processing demands to access dedicated fog nodes and idle processing resources in other user devices (UDs) within the same building. The fog resources within a building complement fog nodes at the access and metro networks and the central cloud data center. A mixed integer linear programming (MILP) model is developed to minimize the total power consumption associated with serving demands over the proposed architecture. A scenario that considers applications with intensive demands is examined to evaluate the energy efficiency of the proposed architecture. A comparison is conducted between allocating the demands in the fog nodes and serving the demands in the conventional cloud data center. Additionally, the proposed architecture is compared with an architecture based on state-of-art Spine-and-Leaf (SL) connectivity. Relative to the SL architecture and serving all the demands in the cloud, the adoption of the PON-based architecture achieves 84% and 86% reductions, respectively.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Cooperative Artificial Neural Networks for Rate-Maximization in Optical Wireless Networks
Authors:
Ahmad Adnan Qidan,
Taisir El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Recently, Optical wireless communication (OWC) have been considered as a key element in the next generation of wireless communications due to its potential in supporting unprecedented communication speeds. In this paper, infrared lasers referred to as vertical-cavity surface-emitting lasers (VCSELs) are used as transmitters sending information to multiple users. In OWC, rate-maximization optimizat…
▽ More
Recently, Optical wireless communication (OWC) have been considered as a key element in the next generation of wireless communications due to its potential in supporting unprecedented communication speeds. In this paper, infrared lasers referred to as vertical-cavity surface-emitting lasers (VCSELs) are used as transmitters sending information to multiple users. In OWC, rate-maximization optimization problems are usually complex due to the high number of optical access points (APs) needed to ensure coverage. Therefore, practical solutions with low computational time are essential to cope with frequent updates in user-requirements that might occur. In this context, we formulate an optimization problem to determine the optimal user association and resource allocation in the network, while the serving time is partitioned into a series of time periods. Therefore, cooperative ANN models are designed to estimate and predict the association and resource allocation variables for each user such that sub-optimal solutions can be obtained within a certain period of time prior to its actual starting, which makes the solutions valid and in accordance with the demands of the users at a given time. The results show the effectiveness of the proposed model in maximizing the sum rate of the network compared with counterpart models. Moreover, ANN-based solutions are close to the optimal ones with low computational time.
△ Less
Submitted 19 January, 2023;
originally announced January 2023.
-
Energy Efficient UAV-Based Service Offloading over Cloud-Fog Architectures
Authors:
Hatem A. Alharbi,
Barzan A. Yosuf,
Mohammad Aldossary,
Jaber Almutairi,
Jaafar M. H. Elmirghani
Abstract:
Unmanned Aerial Vehicles (UAVs) are poised to play a central role in revolutionizing future services offered by the envisioned smart cities, thanks to their agility, flexibility, and cost-efficiency. UAVs are being widely deployed in different verticals including surveillance, search and rescue missions, delivery of items, and as an infrastructure for aerial communications in future wireless netwo…
▽ More
Unmanned Aerial Vehicles (UAVs) are poised to play a central role in revolutionizing future services offered by the envisioned smart cities, thanks to their agility, flexibility, and cost-efficiency. UAVs are being widely deployed in different verticals including surveillance, search and rescue missions, delivery of items, and as an infrastructure for aerial communications in future wireless networks. UAVs can be used to survey target locations, collect raw data from the ground (i.e., video streams), generate computing task(s) and offload it to the available servers for processing. In this work, we formulate a multi-objective optimization framework for both the network resource allocation and the UAV trajectory planning problem using Mixed Integer Linear Programming (MILP) optimization model. In consideration of the different stake holders that may exist in a Cloud-Fog environment, we minimize the sum of a weighted objective function, which allows network operators to tune the weights to emphasize/de-emphasize different cost functions such as the end-to-end network power consumption (EENPC), processing power consumption (PPC), UAVs total flight distance (UAVTFD), and UAVs total power consumption (UAVTPC). Our optimization models and results enable the optimum offloading decisions to be made under different constraints relating to EENPC, PPC, UAVTFD and UAVTPC which we explore in detail. For example, when the UAVs propulsion efficiency (UPE) is at its worst (10% considered), offloading via the macro base station is the best choice and a maximum power saving of 34% can be achieved. Extensive studies on the UAVs coverage path planning (CPP) and computation offloading have been conducted, but none has tackled the issue in a practical Cloud-Fog architecture in which access, metro and core layers are considered in the service offloading in a distributed architecture like the Cloud-Fog.
△ Less
Submitted 14 May, 2022;
originally announced May 2022.
-
High-Speed Imaging Receiver Design for 6G Optical Wireless Communications: A Rate-FOV Trade-Off
Authors:
Mohammad Dehghani Soltani,
Hossein Kazemi,
Elham Sarbazi,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani,
Richard V. Penty,
Ian H. White,
Harald Haas,
Majid Safari
Abstract:
The design of a compact high-speed and wide field of view (FOV) receiver is challenging due to the presence of two well-known trade-offs. The first one is the area-bandwidth trade-off of photodetectors (PDs) and the second one is the gain-FOV trade-off due to the use of optics. The combined effects of these two trade-offs imply that the achievable data rate of an imaging optical receiver is limite…
▽ More
The design of a compact high-speed and wide field of view (FOV) receiver is challenging due to the presence of two well-known trade-offs. The first one is the area-bandwidth trade-off of photodetectors (PDs) and the second one is the gain-FOV trade-off due to the use of optics. The combined effects of these two trade-offs imply that the achievable data rate of an imaging optical receiver is limited by its FOV, i.e., a rate-FOV trade-off. To control the area-bandwidth trade-off, an array of small PDs can be used instead of a single PD. Moreover, in practice, a large-area lens is required to ensure sufficient power collection, which in turn limits the receiver FOV (i.e., gain-FOV trade-off). We propose an imaging receiver design in the form of an array of arrays. To achieve a reasonable receiver FOV, we use individual focusing lens for each PD array rather than a single collection lens for the whole receiver. The proposed array of arrays structure provides an effective method to control both gain-FOV trade-off (via an array of lenses) and area-bandwidth trade-off (via arrays of PDs). We first derive a tractable analytical model for the SNR of an array of PDs where the maximum ratio combining has been employed. Then, we extend the model for the proposed array of arrays structure and the accuracy of the analytical model is verified based on several Optic Studio-based simulations. Next, we formulate an optimization problem to maximize the achievable data rate of the imaging receiver subject to a minimum required FOV. The optimization problem is solved for two commonly used modulation techniques, namely, OOK and direct current biased optical orthogonal frequency division multiplexing with variable rate quadrature amplitude modulation. It is demonstrated that a data rate of ~ 24 Gbps with a FOV of 15 is achievable using OOK with a total receiver size of 2 cm by 2 cm.
△ Less
Submitted 11 May, 2022;
originally announced May 2022.
-
Energy Efficient VM Placement in a Heterogeneous Fog Computing Architecture
Authors:
Abdullah M. Alqahtani,
Barzan Yosuf,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Recent years have witnessed a remarkable development in communication and computing systems, mainly driven by the increasing demands of data and processing intensive applications such as virtual reality, M2M, connected vehicles, IoT services, to name a few. Massive amounts of data will be collected by various mobile and fixed terminals that will need to be processed in order to extract knowledge f…
▽ More
Recent years have witnessed a remarkable development in communication and computing systems, mainly driven by the increasing demands of data and processing intensive applications such as virtual reality, M2M, connected vehicles, IoT services, to name a few. Massive amounts of data will be collected by various mobile and fixed terminals that will need to be processed in order to extract knowledge from the data. Traditionally, a centralized approach is taken for processing the collected data using large data centers connected to a core network. However, due to the scale of the Internet-connected things, transporting raw data all the way to the core network is costly in terms of the power consumption, delay, and privacy. This has compelled researchers to propose different decentralized computing paradigms such as fog computing to process collected data at the network edge close to the terminals and users. In this paper, we study, in a Passive Optical Network (PON)-based collaborative-fog computing system, the impact of the heterogeneity of the fog units capacity and energy-efficiency on the overall energy-efficiency of the fog system. We optimized the virtual machine (VM) placement in this fog system with three fog cells and formulated the problem as a mixed integer linear programming (MILP) optimization model with the objective of minimizing the networking and processing power consumption of the fog system. The results indicate that in our proposed architecture, the processing power consumption is the crucial element to achieve energy efficient VMs placement.
△ Less
Submitted 26 March, 2022;
originally announced March 2022.
-
Energy-Efficient VM Placement in PON-based Data Center Architectures with Cascaded AWGRs
Authors:
Mohammed Alharthi,
Sanaa H. Mohamed,
Barzan Yosuf,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Data centers based on Passive Optical Networks (PONs) can offer scalability, low cost and high energy-efficiency. Application in data centers can use Virtual Machines (VMs) to provide efficient utilization of the physical resources. This paper investigates the impact of VM placement on the energyefficiency in a PON-based data center architecture that utilizes cascaded Arrayed Waveguide Grating Rou…
▽ More
Data centers based on Passive Optical Networks (PONs) can offer scalability, low cost and high energy-efficiency. Application in data centers can use Virtual Machines (VMs) to provide efficient utilization of the physical resources. This paper investigates the impact of VM placement on the energyefficiency in a PON-based data center architecture that utilizes cascaded Arrayed Waveguide Grating Routers (AWGRs). In this paper, we develop a Mixed Integer Linear Programming (MILP) optimization model to optimize the VM placement in the proposed PON-based data center architecture. This optimization aims to minimize the power consumption of the networking and computing by placing the VMs and their demands in the optimum number of resources (i.e., servers and networking devices) in the data center. We first minimize the processing power consumption only and then we minimize the processing and networking power consumption. The results show that a reduction in the networking power consumption by up to 75% is achieved when performing joint minimization of processing and networking power consumption compared to considering the minimization of the processing power consumption only.
△ Less
Submitted 23 March, 2022;
originally announced March 2022.
-
Energy Efficient PON Backhaul Network for a VLC Based Fog Architecture
Authors:
Wafaa B. M. Fadlelmula,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, an energy efficient passive optical network (PON) architecture is proposed for backhaul connectivity in indoor visible light communication (VLC) systems. The proposed network is used to support a fog computing architecture allowing users with processing demands to access dedicated fog nodes and idle processing resources in other user devices within a building. The fog resources with…
▽ More
In this paper, an energy efficient passive optical network (PON) architecture is proposed for backhaul connectivity in indoor visible light communication (VLC) systems. The proposed network is used to support a fog computing architecture allowing users with processing demands to access dedicated fog nodes and idle processing resources in other user devices within a building. The fog resources within a building complement fog nodes at higher layers of the access and metro networks and the central cloud data center. A mixed integer linear programming (MILP) model is developed to minimize the total power consumption associated with serving demands over the proposed architecture. The results show that the PON backhaul network improves the energy efficiency of fog computing by 66% for networking and 12% for processing compared to an architecture based on state-of-the-art Spine-and-Leaf connectivity.
△ Less
Submitted 21 March, 2022;
originally announced March 2022.
-
OWC-enabled Spine and Leaf Architecture Towards Energy Efficient Data Center Networks
Authors:
Abrar S. Alhazmi,
Sanaa H. Mohamed,
T. E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Due to the emergence of new paradigms and services such as 5G/6G, IoT, and more, current deployed wired Data Center Networks (DCNs) are not meeting the required performance metrics due to their limited reconfigurability, scalability, and throughput. To that end, wireless DCNs using technologies such as Optical Wireless Communication (OWC) have become viable and costeffective solutions as they offe…
▽ More
Due to the emergence of new paradigms and services such as 5G/6G, IoT, and more, current deployed wired Data Center Networks (DCNs) are not meeting the required performance metrics due to their limited reconfigurability, scalability, and throughput. To that end, wireless DCNs using technologies such as Optical Wireless Communication (OWC) have become viable and costeffective solutions as they offer higher capacity, better energy efficiency, and better scalability. This paper proposes an OWC-based spine and leaf DCNs where the leaf switches are enabled with OWC transceivers, and the spine switches are replaced by Access Points (APs) in the ceiling connected to a backbone network. The APs are interconnected through a Passive Optical Network (PON) that also connects the architecture with upper network layers. An Infrared (IR) OWC system that employs Wavelength Division Multiplexing (WDM) is proposed to enhance the DCN downlink communication. The simulation (i.e., channel modeling) results show that our proposed data center links achieve good data rates in the data center up to 15 Gbps. For the PON, Arrayed Waveguide Grating Routers (AWGRs) that enable WDM are proposed to connect the APs. We evaluate the performance of the considered architecture in term of its power efficiency compared to traditional spine and leaf data centers. The results show that the OWC-enabled DCN reduces the power consumption by 42% compared to traditional the spine and leaf architecture.
△ Less
Submitted 21 March, 2022;
originally announced March 2022.
-
Random Linear Network Coding in NOMA Optical Wireless Networks
Authors:
Ahmed A. M. Hassan,
Ahmad Adnan Qidan,
Mansourah K. Aljohani,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Optical wireless communication (OWC) has the potential to provide high communication speeds that support the massive use of the Internet that is expected in the near future. In OWC, optical access points (APs) are deployed on the celling to serve multiple users. In this context, efficient multiple access schemes are required to share the resources among the users and align multi-user interference.…
▽ More
Optical wireless communication (OWC) has the potential to provide high communication speeds that support the massive use of the Internet that is expected in the near future. In OWC, optical access points (APs) are deployed on the celling to serve multiple users. In this context, efficient multiple access schemes are required to share the resources among the users and align multi-user interference. Recently, non-orthogonal multiple access (NOMA) has been studied to serve multiple users simultaneously using the same resources, while a different power level is allocated to each user. Despite the acceptable performance of NOMA, users might experience a high packet loss due to high noise, which results from the use of successive interference cancelation (SIC). In this work, random linear network coding (RLNC) is proposed to enhance the performance of NOMA in an optical wireless network where users are divided into multicast groups, and each group contains users that slightly differ in their channel gains. Moreover, a fixed power allocation (FPA) strategy is considered among these groups to avoid complexity. The performance of the proposed scheme is evaluated in terms of total packet success probability. The results show that the proposed scheme is more suitable for the network considered compared to other benchmark schemes such as traditional NOMA and orthogonal transmission schemes. Moreover, the total packet success probability is highly affected by the level of power allocated to each group in all the scenarios.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
Optical Wireless Sytems for Spine and Leaf Data Center Downlinks
Authors:
Abrar S. Alhazmi,
Sanaa H. Mohamed and,
T. E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
The continually growing demands for traffic as a result of advanced technologies in 5G and 6G systems offering services with intensive demands such as IoT and virtual reality applications has resulted in significant performance expectations of data center networks (DCNs). More specifically, DCNs are expected to meet high bandwidth connectivity, high throughput, low latency, and high scalability re…
▽ More
The continually growing demands for traffic as a result of advanced technologies in 5G and 6G systems offering services with intensive demands such as IoT and virtual reality applications has resulted in significant performance expectations of data center networks (DCNs). More specifically, DCNs are expected to meet high bandwidth connectivity, high throughput, low latency, and high scalability requirements. However, the current wired DCN architectures introduce large cabling requirements and limit the ability to reconfigure data centres as they expand. To that end, wireless technologies such as Optical Wireless Communication (OWC) have been proposed as a viable and cost-effective solution to meet the aforementioned requirements. This paper proposes the use of Infrared (IR) OWC systems that employ Wavelength Division Multiplexing (WDM) to enhance the DCN communication in the downlink direction; i.e. from Access Points (APs) in the ceiling, connected to spine switches, to receivers attached to the top of the racks representing leaf switches. The proposed systems utilize Angle Diversity Transmitters (ADTs) mounted on the room ceiling to facilitate inter-rack communication. Two different optical receiver types are considered, namely Angle Diversity Receivers (ADRs) and Wide Field-of-View Receivers (WFOVR). The simulation (i.e. channel modeling) results show that our proposed data center links achieve good data rates in the data centre up to 15 Gbps.
△ Less
Submitted 30 November, 2021;
originally announced November 2021.
-
On Optimizing Rate Splitting in Laser-based Optical Wireless Networks
Authors:
Khulood Alazwary,
Ahmad Adnan Qidan,
Taisir El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Optical wireless communication (OWC) is a promising technology that has the potential to provide Tb/s aggregate rates. In this paper, interference management is studied in a Laser-based optical wireless network where vertical-cavity surface-emitting (VCSEL) lasers are used for data transmission. In particular, rate splitting (RS) and hierarchical rate splitting (HRS) are proposed to align multi-us…
▽ More
Optical wireless communication (OWC) is a promising technology that has the potential to provide Tb/s aggregate rates. In this paper, interference management is studied in a Laser-based optical wireless network where vertical-cavity surface-emitting (VCSEL) lasers are used for data transmission. In particular, rate splitting (RS) and hierarchical rate splitting (HRS) are proposed to align multi-user interference, while maximizing the multiplexing gain of the network. Basically, RS serves multiple users simultaneously by splitting a message of a user into common and private messages, each message with a certain level of power, while on the other side users decode their messages following a specific methodology. The performance of the conventional RS scheme is limited in high density wireless networks. Therefore, the HRS scheme is developed aiming to achieve high rates where users are divided into multiple groups, and a new message called outer common message is used for managing inter-group interference. We formulate an optimization problem that addresses power allocation among the messages of the HRS scheme to further enhance the performance of the network. The results show that the proposed approach provides high achievable rates compared with the conventional RS and HRS schemes in different scenarios.
△ Less
Submitted 14 November, 2021;
originally announced November 2021.
-
Optimized Passive Optical Networks with Cascaded-AWGRs for Data Centers
Authors:
Mohammed Alharthi,
Sanaa H. Mohamed,
Barzan Yosuf,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
The use of Passive Optical Networks (PONs) in modern and future data centers can provide energy efficiency, high capacity, low cost, scalability, and elasticity. This paper introduces a passive optical network design with 2-tier cascaded Arrayed Waveguide Grating Routers (AWGRs) to connect groups of racks (i.e. cells) within a data center. This design employs a Software-Defined Networking (SDN) co…
▽ More
The use of Passive Optical Networks (PONs) in modern and future data centers can provide energy efficiency, high capacity, low cost, scalability, and elasticity. This paper introduces a passive optical network design with 2-tier cascaded Arrayed Waveguide Grating Routers (AWGRs) to connect groups of racks (i.e. cells) within a data center. This design employs a Software-Defined Networking (SDN) controller to manage the routing and assignment of the networking resource while introducing multiple paths between any two cells to improve routing, load balancing and resilience. We provide benchmarking results for the power consumption to compare the energy efficiency of this design to state-of-the-art data centers. The results indicate that the cascaded AWGRs architecture can achieve up to 43% saving in the networking power consumption compared to Fat-Tree data center architecture.
△ Less
Submitted 1 November, 2021;
originally announced November 2021.
-
Angle Diversity Trasmitter For High Speed Data Center Uplink Communications
Authors:
Abrar S. Alhazmi,
Sanaa H. Mohamed,
Osama Z. Alsulami,
T. E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
This paper proposes an uplink optical wireless communication (OWC) link design that can be used by data centers to support communication in spine and leaf architectures between the top of rack leaf switches and large spine switches whose access points are mounted in the ceiling. The use of optical wireless links reduces cabling and allows easy reconfigurability for example when data centres expand…
▽ More
This paper proposes an uplink optical wireless communication (OWC) link design that can be used by data centers to support communication in spine and leaf architectures between the top of rack leaf switches and large spine switches whose access points are mounted in the ceiling. The use of optical wireless links reduces cabling and allows easy reconfigurability for example when data centres expand. We consider three racks in a data center where each rack contains an Angle Diversity Transmitter (ADT) positioned on the top of the rack to realize the uplink function of a top-of-the-rack (ToR) or a leaf switch. Four receivers are considered to be installed on the ceiling where each is connected to a spine switch. Two types of optical receivers are studied which are a Wide Field-of-View Receiver (WFOVR) and an Angle Diversity Receiver (ADR). The performance of the proposed system is evaluated when the links run at data rates higher than 19 Gbps. The results indicate that the proposed approach achieves excellent performance using simple On-Off Keying (OOK)
△ Less
Submitted 29 October, 2021;
originally announced October 2021.
-
Energy Efficient Resource Allocation in Federated Fog Computing Networks
Authors:
Abdullah M. Alqahtani,
Barzan Yosuf,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
There is a continuous growth in demand for time sensitive applications which has shifted the cloud paradigm from a centralized computing architecture towards distributed heterogeneous computing platforms where resources located at the edge of the network are used to provide cloud-like services. This paradigm is widely known as fog computing. Virtual machines (VMs) have been widely utilized in both…
▽ More
There is a continuous growth in demand for time sensitive applications which has shifted the cloud paradigm from a centralized computing architecture towards distributed heterogeneous computing platforms where resources located at the edge of the network are used to provide cloud-like services. This paradigm is widely known as fog computing. Virtual machines (VMs) have been widely utilized in both paradigms to enhance the network scalability, improve resource utilization, and energy efficiency. Moreover, Passive Optical Networks (PONs) are a technology suited to handling the enormous volumes of data generated in the access network due to their energy efficiency and large bandwidth. In this paper, we utilize a PON to provide the connectivity between multiple distributed fog units to achieve federated (i.e. cooperative) computing units in the access network to serve intensive demands. We propose a mixed integer linear program (MILP) to optimize the VM placement in the federated fog computing units with the objective of minimizing the total power consumption while considering inter-VM traffic. The results show a significant power saving as a result of the proposed optimization model by up to 52%, in the VM-allocation compared to a baseline approach that allocates the VM requests while neglecting the power consumption and inter-VMs traffic in the optimization framework.
△ Less
Submitted 28 October, 2021;
originally announced October 2021.
-
Blind Interference Alignment in 6G Optical Wireless Communications
Authors:
Ahmad Adnan Qidan,
Taisir El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
In recent years, the demand for high speed wireless networking has increased considerably due to the enormous number of devices connected to the Internet. In this context, optical wireless communication (OWC) has received tremendous interest in the context of next generation wireless networks where OWC offers a huge unlicensed bandwidth using optical bands. OWC systems are directional and can natu…
▽ More
In recent years, the demand for high speed wireless networking has increased considerably due to the enormous number of devices connected to the Internet. In this context, optical wireless communication (OWC) has received tremendous interest in the context of next generation wireless networks where OWC offers a huge unlicensed bandwidth using optical bands. OWC systems are directional and can naturally provide multiple-input and multiple-output (MIMO) configurations serving multiple users using a high number of transmitters in the indoor environment to ensure coverage. Therefore, multiuser interference must be managed efficiently to enhance the performance of OWC networks considering different metrics. A transmission scheme referred to as blind interference alignment (BIA) is proposed for OWC systems to maximize the multiplexing gain without the need for channel state information (CSI) at the transmitters, which is difficult to achieve in MIMO scenarios. However, standard BIA avoids the need for CSI at the cost of requiring channel coherence time large enough for transmitting the whole transmission block. Moreover, the methodology of BIA results in increased noise with increase in the number of transmitters and users. Therefore, various network topologies such as network centric (NC) and user centric (UC) designs are proposed to relax the limitations of BIA where these topologies divide the receiving area into multiple clusters. The results show a significant enhancement in the performance of topological BIA compared with standard BIA.
△ Less
Submitted 25 September, 2021;
originally announced September 2021.
-
Reinforcement Learning for Resource Allocation in Steerable Laser-based Optical Wireless Systems
Authors:
Abdelrahman S. Elgamal,
Osama Z. Alsulami,
Ahmad Adnan Qidan,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Vertical Cavity Surface Emitting Lasers (VCSELs) have demonstrated suitability for data transmission in indoor optical wireless communication (OWC) systems due to the high modulation bandwidth and low manufacturing cost of these sources. Specifically, resource allocation is one of the major challenges that can affect the performance of multi-user optical wireless systems. In this paper, an optimis…
▽ More
Vertical Cavity Surface Emitting Lasers (VCSELs) have demonstrated suitability for data transmission in indoor optical wireless communication (OWC) systems due to the high modulation bandwidth and low manufacturing cost of these sources. Specifically, resource allocation is one of the major challenges that can affect the performance of multi-user optical wireless systems. In this paper, an optimisation problem is formulated to optimally assign each user to an optical access point (AP) composed of multiple VCSELs within a VCSEL array at a certain time to maximise the signal to interference plus noise ratio (SINR). In this context, a mixed-integer linear programming (MILP) model is introduced to solve this optimisation problem. Despite the optimality of the MILP model, it is considered impractical due to its high complexity, high memory and full system information requirements. Therefore, reinforcement Learning (RL) is considered, which recently has been widely investigated as a practical solution for various optimization problems in cellular networks due to its ability to interact with environments with no previous experience. In particular, a Q-learning (QL) algorithm is investigated to perform resource management in a steerable VCSEL-based OWC systems. The results demonstrate the ability of the QL algorithm to achieve optimal solutions close to the MILP model. Moreover, the adoption of beam steering, using holograms implemented by exploiting liquid crystal devices, results in further enhancement in the performance of the network considered.
△ Less
Submitted 21 June, 2021;
originally announced June 2021.
-
Optical Networks for Composable Data Centers
Authors:
Opeyemi O. Ajibola,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Composable data centers (DCs) have been proposed to enable greater efficiencies as the uptake of on-demand computing services grows. In this article we give an overview of composable DCs by discussing their enabling technologies, benefits, challenges, and research directions. We then describe a network for composable DCs that leverages optical communication technologies and components to implement…
▽ More
Composable data centers (DCs) have been proposed to enable greater efficiencies as the uptake of on-demand computing services grows. In this article we give an overview of composable DCs by discussing their enabling technologies, benefits, challenges, and research directions. We then describe a network for composable DCs that leverages optical communication technologies and components to implement a targeted design. Relative to the implementation of a generic design that requires a (high capacity) dedicated transceiver on each point-to-point link on a mesh optical fabric in a composable DC rack, the targeted design can significantly reduce capital expenditure (by up to 34 times) because fewer transceivers are used. This is achieved with little or no degradation of expected performance in composable DCs.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
Network Topologies for Composable Data Centres
Authors:
Opeyemi O. Ajibola,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Suitable composable data center networks (DCNs) are essential to support the disaggregation of compute components in highly efficient next generation data centers (DCs). However, designing such composable DCNs can be challenging. A composable DCN that adopts a full mesh backplane between disaggregated compute components within a rack and employs dedicated interfaces on each point-to-point link is…
▽ More
Suitable composable data center networks (DCNs) are essential to support the disaggregation of compute components in highly efficient next generation data centers (DCs). However, designing such composable DCNs can be challenging. A composable DCN that adopts a full mesh backplane between disaggregated compute components within a rack and employs dedicated interfaces on each point-to-point link is wasteful and expensive. In this paper, we propose and describe two (i.e., electrical, and electrical-optical) variants of a network for composable DC (NetCoD). NetCoD adopts a targeted design to reduce the number of transceivers required when a mesh physical backplane is deployed between disaggregated compute components in the same rack. The targeted design leverages optical communication techniques and components to achieve this with minimal or no network performance degradation. We formulate a MILP model to evaluate the performance of both variants of NetCoD in rack-scale composable DCs that implement different forms of disaggregation. The electrical-optical variant of NetCoD achieves similar performance as a reference network while utilizing fewer transceivers per compute node. The targeted adoption of optical technologies by both variants of NetCoD achieves greater (4 - 5 times greater) utilization of available network throughput than the reference network which implements a generic design. Under the various forms of disaggregation considered, both variant of NetCoD achieve near-optimal compute energy efficiency in the composable DC while satisfying both compute and network constraints. This is because marginal concession of optimal compute energy efficiency is often required to achieve overall optimal energy efficiency in composable DCs.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
Rate Splitting in VCSEL-based Optical Wireless Networks
Authors:
Khulood Alazwary,
Ahmad Adnan Qidan,
Taisir El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Optical wireless communication is an effective potential solution for enabling high speed next generation cellular networks. In this paper, laser sources, in particular, vertical-cavity surface-emitting (VCSEL) lasers are used for data transmission due to their high modulation speed compared with light emitting diode (LED) sources. To manage multi-user interference, rate splitting (RS) is implemen…
▽ More
Optical wireless communication is an effective potential solution for enabling high speed next generation cellular networks. In this paper, laser sources, in particular, vertical-cavity surface-emitting (VCSEL) lasers are used for data transmission due to their high modulation speed compared with light emitting diode (LED) sources. To manage multi-user interference, rate splitting (RS) is implemented where the message of a user is split into common and private parts. However, the performance of RS is limited in high density networks. Therefore, hierarchical rate splitting (HRS) particularly suited in high density networks is considered. The results demonstrate the high data rate achieved by using VCSELs. Moreover, HRS is more suitable for achieving high performance in optical networks compared with RS.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Q-learning algorithm for resource allocation in WDMA-based optical wireless communication networks
Authors:
Abdelrahman S. Elgamal,
Osama Z. Alsulami,
Ahmad Adnan Qidan,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Visible Light Communication (VLC) has been widely investigated during the last decade due to its ability to provide high data rates with low power consumption. In general, resource management is an important issue in cellular networks that can highly effect their performance. In this paper, an optimisation problem is formulated to assign each user to an optimal access point and a wavelength at a g…
▽ More
Visible Light Communication (VLC) has been widely investigated during the last decade due to its ability to provide high data rates with low power consumption. In general, resource management is an important issue in cellular networks that can highly effect their performance. In this paper, an optimisation problem is formulated to assign each user to an optimal access point and a wavelength at a given time. This problem can be solved using mixed integer linear programming (MILP). However, using MILP is not considered a practical solution due to its complexity and memory requirements. In addition, accurate information must be provided to perform the resource allocation. Therefore, the optimisation problem is reformulated using reinforcement learning (RL), which has recently received tremendous interest due to its ability to interact with any environment without prior knowledge. In this paper, we investigate solving the resource allocation optimisation problem in VLC systems using the basic Q-learning algorithm. Two scenarios are simulated to compare the results with the previously proposed MILP model. The results demonstrate the ability of the Q-learning algorithm to provide optimal solutions close to the MILP model without prior knowledge of the system.
△ Less
Submitted 22 May, 2021;
originally announced May 2021.
-
Energy Minimized Federated Fog Computing over Passive Optical Networks
Authors:
Abdullah M. Alqahtani,
Barzan Yosuf,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
The rapid growth of time-sensitive applications and services has driven enhancements to computing infrastructures. The main challenge that needs addressing for these applications is the optimal placement of the end-users demands to reduce the total power consumption and delay. One of the widely adopted paradigms to address such a challenge is fog computing. Placing fog units close to end-users at…
▽ More
The rapid growth of time-sensitive applications and services has driven enhancements to computing infrastructures. The main challenge that needs addressing for these applications is the optimal placement of the end-users demands to reduce the total power consumption and delay. One of the widely adopted paradigms to address such a challenge is fog computing. Placing fog units close to end-users at the edge of the network can help mitigate some of the latency and energy efficiency issues. Compared to the traditional hyperscale cloud data centres, fog computing units are constrained by computational power, hence, the capacity of fog units plays a critical role in meeting the stringent demands of the end-users due to intensive processing workloads. In this paper, we aim to optimize the placement of virtual machines (VMs) demands originating from end-users in a fog computing setting by formulating a Mixed Integer Linear Programming (MILP) model to minimize the total power consumption through the use of a federated architecture made up of multiple distributed fog cells. The obtained results show an increase in processing capacity in the fog layer and a reduction in the power consumption by up to 26% compared to the Non-Federated fogs network.
△ Less
Submitted 21 May, 2021;
originally announced May 2021.
-
Energy-Efficient Distributed Machine Learning in Cloud Fog Networks
Authors:
Mohammed M. Alenazi,
Barzan A. Yosuf,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Massive amounts of data are expected to be generated by the billions of objects that form the Internet of Things (IoT). A variety of automated services such as monitoring will largely depend on the use of different Machine Learning (ML) algorithms. Traditionally, ML models are processed by centralized cloud data centers, where IoT readings are offloaded to the cloud via multiple networking hops in…
▽ More
Massive amounts of data are expected to be generated by the billions of objects that form the Internet of Things (IoT). A variety of automated services such as monitoring will largely depend on the use of different Machine Learning (ML) algorithms. Traditionally, ML models are processed by centralized cloud data centers, where IoT readings are offloaded to the cloud via multiple networking hops in the access, metro, and core layers. This approach will inevitably lead to excessive networking power consumptions as well as Quality-of-Service (QoS) degradation such as increased latency. Instead, in this paper, we propose a distributed ML approach where the processing can take place in intermediary devices such as IoT nodes and fog servers in addition to the cloud. We abstract the ML models into Virtual Service Requests (VSRs) to represent multiple interconnected layers of a Deep Neural Network (DNN). Using Mixed Integer Linear Programming (MILP), we design an optimization model that allocates the layers of a DNN in a Cloud/Fog Network (CFN) in an energy efficient way. We evaluate the impact of DNN input distribution on the performance of the CFN and compare the energy efficiency of this approach to the baseline where all layers of DNNs are processed in the centralized Cloud Data Center (CDC).
△ Less
Submitted 20 May, 2021;
originally announced May 2021.
-
Energy-Efficient AI over a Virtualized Cloud Fog Network
Authors:
Barzan A. Yosuf,
Sanaa H. Mohamed,
Mohamed Alenazi,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Deep Neural Networks (DNNs) have served as a catalyst in introducing a plethora of next-generation services in the era of Internet of Things (IoT), thanks to the availability of massive amounts of data collected by the objects on the edge. Currently, DNN models are used to deliver many Artificial Intelligence (AI) services that include image and natural language processing, speech recognition, and…
▽ More
Deep Neural Networks (DNNs) have served as a catalyst in introducing a plethora of next-generation services in the era of Internet of Things (IoT), thanks to the availability of massive amounts of data collected by the objects on the edge. Currently, DNN models are used to deliver many Artificial Intelligence (AI) services that include image and natural language processing, speech recognition, and robotics. Accordingly, such services utilize various DNN models that make it computationally intensive for deployment on the edge devices alone. Thus, most AI models are offloaded to distant cloud data centers (CDCs), which tend to consolidate large amounts of computing and storage resources into one or more CDCs. Deploying services in the CDC will inevitably lead to excessive latencies and overall increase in power consumption. Instead, fog computing allows for cloud services to be extended to the edge of the network, which allows for data processing to be performed closer to the end-user device. However, different from cloud data centers, fog nodes have limited computational power and are highly distributed in the network. In this paper, using Mixed Integer Linear Programming (MILP), we formulate the placement of DNN inference models, which is abstracted as a network embedding problem in a Cloud Fog Network (CFN) architecture, where power savings are introduced through trade-offs between processing and networking. We study the performance of the CFN architecture by comparing the energy savings when compared to the baseline approach which is the CDC.
△ Less
Submitted 7 May, 2021;
originally announced May 2021.
-
A Tb/s Indoor MIMO Optical Wireless Backhaul System Using VCSEL Arrays
Authors:
Hossein Kazemi,
Elham Sarbazi,
Mohammad Dehghani Soltani,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani,
Richard V. Penty,
Ian H. White,
Majid Safari,
Harald Haas
Abstract:
In this paper, the design of a multiple-input multiple-output (MIMO) optical wireless communication (OWC) link based on vertical cavity surface emitting laser (VCSEL) arrays is systematically carried out with the aim to support data rates in excess of 1 Tb/s for the backhaul of sixth generation (6G) indoor wireless networks. The proposed design combines direct current optical orthogonal frequency…
▽ More
In this paper, the design of a multiple-input multiple-output (MIMO) optical wireless communication (OWC) link based on vertical cavity surface emitting laser (VCSEL) arrays is systematically carried out with the aim to support data rates in excess of 1 Tb/s for the backhaul of sixth generation (6G) indoor wireless networks. The proposed design combines direct current optical orthogonal frequency division multiplexing (DCO-OFDM) and a spatial multiplexing MIMO architecture. For such an ultra-high-speed line-of-sight (LOS) OWC link with low divergence laser beams, maintaining alignment is of high importance. In this paper, two types of misalignment error between the transmitter and receiver are distinguished, namely, radial displacement error and orientation angle error, and they are thoroughly modeled in a unified analytical framework assuming Gaussian laser beams, resulting in a generalized misalignment model (GMM). The derived GMM is then extended to MIMO arrays and the performance of the MIMO-OFDM OWC system is analyzed in terms of the aggregate data rate. Novel insights are provided into the system performance based on computer simulations by studying various influential factors such as beam waist, array configuration and different misalignment errors, which can be used as guidelines for designing short range Tb/s MIMO OWC systems.
△ Less
Submitted 4 April, 2022; v1 submitted 19 February, 2021;
originally announced February 2021.
-
Power Minimization in Vehicular Cloud Architecture
Authors:
Fatemah S. Behbehani,
Taisir Elgorashi,
Jaafar M. H. Elmirghani
Abstract:
Modern vehicles equipped with on-board units (OBU) are playing an essential role in the smart city revolution. The vehicular processing resources, however, are not used to their fullest potential. The concept of vehicular clouds is proposed to exploit the underutilized vehicular resources to supplement cloud computing services to relieve the burden on cloud data centers and improve quality of serv…
▽ More
Modern vehicles equipped with on-board units (OBU) are playing an essential role in the smart city revolution. The vehicular processing resources, however, are not used to their fullest potential. The concept of vehicular clouds is proposed to exploit the underutilized vehicular resources to supplement cloud computing services to relieve the burden on cloud data centers and improve quality of service. In this paper we introduce a vehicular cloud architecture supported by fixed edge computing nodes and the central cloud. A mixed integer linear programming (MLP) model is developed to optimize the allocation of the computing demands in the distributed architecture while minimizing power consumption. The results show power savings as high as 84% over processing in the conventional cloud. A heuristic with performance approaching that of the MILP model is developed to allocate computing demands in real time.
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
Safety Analysis for Laser-based Optical Wireless Communications: A Tutorial
Authors:
Mohammad Dehghani Soltani,
Elham Sarbazi,
Nikolaos Bamiedakis,
Priyanka de Souza,
Hossein Kazemi,
Jaafar M. H. Elmirghani,
Ian H. White,
Richard V. Penty,
Harald Haas,
Majid Safari
Abstract:
Light amplification by stimulated emission of radiation (laser) sources have many advantages for use in high data rate optical wireless communications. In particular, the low cost and high-bandwidth properties of laser sources such as vertical-cavity surface-emitting lasers (VCSELs) make them attractive for future indoor optical wireless communications. In order to be integrated into future indoor…
▽ More
Light amplification by stimulated emission of radiation (laser) sources have many advantages for use in high data rate optical wireless communications. In particular, the low cost and high-bandwidth properties of laser sources such as vertical-cavity surface-emitting lasers (VCSELs) make them attractive for future indoor optical wireless communications. In order to be integrated into future indoor networks, such lasers should conform to eye safety regulations determined by the international electrotechnical commission (IEC) standards for laser safety. In this paper, we provide a detailed study of beam propagation to evaluate the received power of various laser sources, based on which as well as the maximum permissible exposure (MPE) defined by the IEC 60825-1:2014 standard, we establish a comprehensive framework for eye safety analyses. This framework allows us to calculate the maximum allowable transmit power, which is crucial in the design of a reliable and safe laser-based wireless communication system. Initially, we consider a single-mode Gaussian beam and calculate the maximum permissible transmit power. Subsequently, we generalize this approach for higher-mode beams. It is shown that the M-squared-based approach for analysis of multimode lasers ensures the IEC eye safety limits, however, in some scenarios, it can be too conservative compared to the precise beam decomposition method. Laser safety analyses with consideration of optical elements such as lens and diffuser, as well as for VCSEL array have been also presented. Skin safety, as another significant factor of laser safety, has also been investigated in this paper. We have studied the impacts of various parameters such as wavelength, exposure duration and the divergence angle of laser sources on the safety analysis by presenting insightful results.
△ Less
Submitted 5 May, 2021; v1 submitted 17 February, 2021;
originally announced February 2021.
-
Resilient Architectures for Free Space Optical Wireless Interconnection Systems
Authors:
Sanaa Hamid Mohamed,
Osama Zwaid Alsulami,
Taisir E. H. El-Gorashi,
Mohammed T. Alresheedi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, we propose the use of two Passive Optical Network (PON)-based network architectures to connect free-space Optical Wireless Communication (OWC) Access Points (APs) within a room with multiple users. We optimize through a Mixed Linear Integer Programming (MILP) model the assignment of mobile OWC users to more than one AP to improve the resilience of the fronthaul network, i.e the OWC…
▽ More
In this paper, we propose the use of two Passive Optical Network (PON)-based network architectures to connect free-space Optical Wireless Communication (OWC) Access Points (APs) within a room with multiple users. We optimize through a Mixed Linear Integer Programming (MILP) model the assignment of mobile OWC users to more than one AP to improve the resilience of the fronthaul network, i.e the OWC system and the wired network linked to APs, and study the impact of users distribution and channel characteristics.
△ Less
Submitted 10 February, 2021;
originally announced February 2021.
-
Disaggregation for Energy Efficient Fog in Future 6G Networks
Authors:
Opeyemi O. Ajibola,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
We study the benefits of adopting server disaggregation in the fog computing tier by evaluating energy efficient placement of interactive apps in a future fog 6G network. Using a mixed integer linear programming (MILP) model, we compare the adoption of traditional server (TS) and disaggregated server (DS) architectures in a fog network comprising of selected fog computing sites in the metro and ac…
▽ More
We study the benefits of adopting server disaggregation in the fog computing tier by evaluating energy efficient placement of interactive apps in a future fog 6G network. Using a mixed integer linear programming (MILP) model, we compare the adoption of traditional server (TS) and disaggregated server (DS) architectures in a fog network comprising of selected fog computing sites in the metro and access networks. Relative to the use of TSs, our results show that the adoption of DS improves the energy efficiency of the fog network and enables up to 18% reduction in total fog computing power consumption. More instances of interactive fog apps are provisioned in a fog network that is implemented over a network topology with high delay penalty. This ensures that minimal delay is experienced by distributed users. Our result also shows that the proximity of fog computing sites such as metro-central offices and radio cell sites to geo-distributed users of interactive fog applications make them important edge locations for provisioning moderately delay sensitive fog apps. However, fog applications with more stringent delay thresholds require in situ processing at directly connected radio cell sites or at the location of the requesting users. Finally, we propose a heuristic for energy efficient and delay aware placement of interactive fog apps in a fog network which replicates the trends observed during comprehensive analysis of the exact results obtained by solving the MILP model formulated in this paper. Our results and proposed MILP and heuristic provide a good reference and tool for fog network design and deployment.
△ Less
Submitted 1 February, 2021;
originally announced February 2021.
-
Optimized Energy Efficient Virtualization and Content Caching in 5G Networks
Authors:
Ahmed N. Al-Quzweeni,
Ahmed Q. Lawey,
Taisir E. H. Elgorashi,
Jaafar M. H. Elmirghani
Abstract:
Network function virtualization (NFV) and content caching are two promising technologies that hold great potential for network operators and designers. This paper optimizes the deployment of NFV and content caching in 5G networks and focuses on the associated power consumption savings. In addition, it introduces an approach to combine content caching with NFV in one integrated architecture for ene…
▽ More
Network function virtualization (NFV) and content caching are two promising technologies that hold great potential for network operators and designers. This paper optimizes the deployment of NFV and content caching in 5G networks and focuses on the associated power consumption savings. In addition, it introduces an approach to combine content caching with NFV in one integrated architecture for energy aware 5G networks. A mixed integer linear programming (MILP) model has been developed to minimize the total power consumption by jointly optimizing the cache size, virtual machine (VM) workload, and the locations of both cache nodes and VMs. The results were investigated under the impact of core network virtual machines (CNVMs) inter-traffic. The result show that the optical line terminal (OLT) access network nodes are the optimum location for content caching and for hosting VMs during busy times of the day whilst IP over WDM core network nodes are the optimum locations for caching and VM placement during off-peak time. Furthermore, the results reveal that a virtualization-only approach is better than a caching-only approach for video streaming services where the virtualization-only approach compared to caching-only approach, achieves a maximum power saving of 7% (average 5%) when no CNVMs inter-traffic is considered and 6% (average 4%) with CNVMs inter-traffic at 10% of the total backhaul traffic. On the other hand, the integrated approach has a maximum power saving of 15% (average 9%) with and without CNVMs inter-traffic compared to the virtualization-only approach, and it achieves a maximum power saving of 21% (average 13%) without CNVMs inter-traffic and 20% (average 12%) when CNVMs inter-traffic is considered compared with the caching-only approach. In order to validate the MILP models and achieve real-time operation in our approaches, a heuristic was developed.
△ Less
Submitted 1 February, 2021;
originally announced February 2021.
-
Energy Efficient Placement of Workloads in Composable Data Center Networks
Authors:
Opeyemi O. Ajibola,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
This paper studies the energy efficiency of composable datacentre (DC) infrastructures over network topologies. Using a mixed integer linear programming (MILP) model, we compare the performance of disaggregation at rack-scale and pod-scale over selected electrical, optical and hybrid network topologies relative to a traditional DC. Relative to a pod-scale DC, the results show that physical disaggr…
▽ More
This paper studies the energy efficiency of composable datacentre (DC) infrastructures over network topologies. Using a mixed integer linear programming (MILP) model, we compare the performance of disaggregation at rack-scale and pod-scale over selected electrical, optical and hybrid network topologies relative to a traditional DC. Relative to a pod-scale DC, the results show that physical disaggregation at rack-scale is sufficient for optimal efficiency when the optical network topology is adopted and resource components are allocated in a suitable manner. The optical network topology also enables optimal energy efficiency in composable DCs. The paper also studies logical disaggregation of traditional DC servers over an optical network topology. Relative to physical disaggregation at rack-scale, logical disaggregation of server resources within each rack enables marginal fall in the total DC power consumption (TDPC) due to improved resource demands placement. Hence, an adaptable composable infrastructure that can support both in memory (access) latency sensitive and insensitive workloads is enabled. We also conduct a study of the adoption of micro-service architecture in both traditional and composable DCs. Our results show that increasing the modularity of workloads improves the energy efficiency in traditional DCs, but disproportionate utilization of DC resources persists. A combination of disaggregation and micro-services achieved up to 23% reduction in the TDPC of the traditional DC by enabling optimal resources utilization and energy efficiencies. Finally, we propose a heuristic for energy efficient placement of workloads in composable DCs which replicates the trends produced by the MILP model formulated in this paper.
△ Less
Submitted 20 January, 2021;
originally announced January 2021.
-
Resilient Energy Efficient Healthcare Monitoring Infrastructure with Server and Network Protection
Authors:
Ida Syafiza M. Isa,
Taisir E. H. El-Gorashi,
Mohamed O. I. Musa,
J. M. H. Elmirghani
Abstract:
In this paper, a 1+1 server protection scheme is considered where two servers, a primary and a secondary processing server are used to serve ECG monitoring applications concurrently. The infrastructure is designed to be resilient against server failure under two scenarios related to the geographic location of primary and secondary servers and resilient against both server and network failures. A M…
▽ More
In this paper, a 1+1 server protection scheme is considered where two servers, a primary and a secondary processing server are used to serve ECG monitoring applications concurrently. The infrastructure is designed to be resilient against server failure under two scenarios related to the geographic location of primary and secondary servers and resilient against both server and network failures. A Mixed Integer Linear Programming (MILP) model is used to optimise the number and locations of both primary and secondary processing servers so that the energy consumption of the networking equipment and processing are minimised. The results show that considering a scenario for server protection without geographical constraints compared to the non-resilient scenario has resulted in both network and processing energy penalty as the traffic is doubled. The results also reveal that increasing the level of resilience to consider geographical constraints compared to case without geographical constraints resulted in higher network energy penalty when the demand is low as more nodes are utilised to place the processing servers under the geographic constraints. Also, increasing the level of resilience to consider network protection with link and node disjoint selection has resulted in a low network energy penalty at high demands due to the activation of a large part of the network in any case due to the demands. However, the results show that the network energy penalty is reduced with the increasing number of processing servers at each candidate node. Meanwhile, the same energy for processing is consumed regardless of the increasing level of resilience as the same number of processing servers are utilised. A heuristic is developed for each resilience scenario for real-time implementation where the results show that the performance of the heuristic is approaching the results of the MILP model.
△ Less
Submitted 28 October, 2020;
originally announced October 2020.
-
Cloud Fog Architectures in 6G Networks
Authors:
Barzan A. Yosuf,
Amal A. Alahmadi,
T. E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Prior to the advent of the cloud, storage and processing services were accommodated by specialized hardware, however, this approach introduced a number of challenges in terms of scalability, energy efficiency, and cost. Then came the concept of cloud computing, where to some extent, the issue of massive storage and computation was dealt with by centralized data centers that are accessed via the co…
▽ More
Prior to the advent of the cloud, storage and processing services were accommodated by specialized hardware, however, this approach introduced a number of challenges in terms of scalability, energy efficiency, and cost. Then came the concept of cloud computing, where to some extent, the issue of massive storage and computation was dealt with by centralized data centers that are accessed via the core network. The cloud has remained with us thus far, however, this has introduced further challenges among which, latency and energy efficiency are of the pinnacle. With the increase in embedded devices intelligence came the concept of the Fog. The availability of massive numbers of storage and computational devices at the edge of the network, where some are owned and deployed by the end-users themselves but most by service operators. This means that cloud services are pushed further out from the core towards the edge of the network, hence reduced latency is achieved. Fog nodes are massively distributed in the network, some benefit from wired connections, and others are connected via wireless links. The question of where to allocate services remains an important task and requires extensive attention. This chapter introduces and evaluates cloud fog architectures in 6G networks paying special attention to latency, energy efficiency, scalability, and the trade-offs between distributed and centralized processing resources.
△ Less
Submitted 10 August, 2020;
originally announced August 2020.
-
Optimizing Co-flows Scheduling and Routing in Data Centre Networks for Big Data Applications
Authors:
Sanaa Hamid Mohamed,
Ali Hammadi,
Taisir E. H. El-Gorashi,
Jaafar Mohamed Hashim Elmirghani
Abstract:
This paper optimizes the scheduling and routing of the co-flows of MapReduce shuffling phase in state-of-the-art and proposed Passive Optical Networking (PON)-based Data Centre Network (DCN) architectures. A time-slotted Mixed Integer Linear Programming (MILP) model is developed and used for the optimization with the objective of minimizing either the total energy consumption or the completion tim…
▽ More
This paper optimizes the scheduling and routing of the co-flows of MapReduce shuffling phase in state-of-the-art and proposed Passive Optical Networking (PON)-based Data Centre Network (DCN) architectures. A time-slotted Mixed Integer Linear Programming (MILP) model is developed and used for the optimization with the objective of minimizing either the total energy consumption or the completion time. The DCN architectures include four state-of-the-art electronic switching architectures which are spine-leaf, Fat-tree, BCube, and DCell data centres. The proposed PON-based DCN architectures include two designs that utilize ports in Optical Line Terminal (OLT) line cards for inter and possibly intra data centre networking in addition to passive interconnects for the intra data centre networking between different PON groups (i.e. racks) within a PON cell (i.e. number of PON groups connected to a single OLT port). The first design is a switch-centric design that uses two Arrayed Waveguide Grating Routers (AWGRs) and the second is a server-centric design. The study also considers different traffic patterns defined according to the distribution of map and reduce tasks in the servers and data skewness.
△ Less
Submitted 8 August, 2020;
originally announced August 2020.
-
Energy Efficient Fog based Healthcare Monitoring Infrastructure
Authors:
Ida Syafiza M. Isa,
Taisir E. H. El-Gorashi,
Mohamed O. I. Musa,
Jaafar M. H. Elmirghani
Abstract:
Recent advances in mobile technologies and cloud computing services have inspired the development of cloud-based real-time health monitoring systems. However, the transfer of health-related data to the cloud contributes to the burden on the networking infrastructures, leading to high latency and increased power consumption. Fog computing is introduced to relieve this burden by bringing services to…
▽ More
Recent advances in mobile technologies and cloud computing services have inspired the development of cloud-based real-time health monitoring systems. However, the transfer of health-related data to the cloud contributes to the burden on the networking infrastructures, leading to high latency and increased power consumption. Fog computing is introduced to relieve this burden by bringing services to the users proximity. This study proposes a new fog computing architecture for health monitoring applications based on a Gigabit Passive Optical Network (GPON) access network. An Energy-Efficient Fog Computing (EEFC) model is developed using Mixed Integer Linear Programming (MILP) to optimize the number and location of fog devices at the network edge to process and analyze the health data for energy-efficient fog computing. The performance of the EEFC model at low data rates and high data rates health applications is studied. The outcome of the study reveals that a total energy saving of 36% and 52% are attained via processing and analysis the health data at the fog in comparison to conventional processing and analysis at the central cloud for low data rate application and high data rate application, respectively. We also developed a real-time heuristic; Energy Optimized Fog Computing (EOFC) heuristic, with energy consumption performance approaching the EEFC model. Furthermore, we examined the energy efficiency improvements under different scenarios of devices idle power consumption and traffic volume.
△ Less
Submitted 27 July, 2020;
originally announced July 2020.
-
Optimization of Processing Allocation in Vehicular Edge Cloud based Architecture
Authors:
Amal A. Alahmadi,
T. E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Vehicular edge computing is a new distributed processing architecture that exploits the revolution in the processing capabilities of vehicles to provide energy efficient services and low delay for Internet of Things (IoT)-based systems. Edge computing relies on a set of distributed processing nodes (i.e. vehicles) that are located close to the end user. In this paper, we consider a vehicular edge…
▽ More
Vehicular edge computing is a new distributed processing architecture that exploits the revolution in the processing capabilities of vehicles to provide energy efficient services and low delay for Internet of Things (IoT)-based systems. Edge computing relies on a set of distributed processing nodes (i.e. vehicles) that are located close to the end user. In this paper, we consider a vehicular edge cloud (VEC) consisting of a set of vehicle clusters that form a temporal vehicular cloud by combining their computational resources in the cluster. We tackle the problem of processing allocation in the proposed vehicular edge architecture by develo** a Mixed Integer Linear Programming (MILP) optimization model that jointly minimizes power consumption, propagation delay, and queuing delay. The results show that the closer the processing node (PN) is to the access point (AP), the lower the power consumption and delay, as the distance and number of hops affect the propagation delay and queuing delay. However, the queuing delay at the AP becomes a limiting factor when it operates at a low service rate compared to the traffic arrival rate. Thus, processing tasks at the vehicular nodes (VN) was avoided whenever the objective function included queueing delay and the AP operated at a low service rate. Increase in the AP service rate results in a lower queuing delay and better VN utilization.
△ Less
Submitted 23 July, 2020;
originally announced July 2020.
-
Blackout Resilient Optical Core Network
Authors:
Zaid H. Nasralla,
Taisir E. H. Elgorashi,
Jaafar M. H. Elmirghani
Abstract:
A disaster may not necessarily demolish the telecommunications infrastructure, but instead it might affect the national grid and cause blackouts, consequently disrupting the network operation unless there is an alternative power source(s). In this paper, power outages are considered, and the telecommunication network performance is evaluated during a blackout. Two approaches are presented to minim…
▽ More
A disaster may not necessarily demolish the telecommunications infrastructure, but instead it might affect the national grid and cause blackouts, consequently disrupting the network operation unless there is an alternative power source(s). In this paper, power outages are considered, and the telecommunication network performance is evaluated during a blackout. Two approaches are presented to minimize the impact of power outage and maximize the survival time of the blackout node. A mixed integer linear programming (MILP) model is developed to evaluate the network performance under a single node blackout scenario. The model is used to evaluate the network under the two proposed scenarios. The results show that the proposed approach succeeds in extending the network life time while minimizing the required amount of backup energy.
△ Less
Submitted 23 July, 2020;
originally announced July 2020.
-
Energy Efficient Processing Allocation in Opportunistic Cloud-Fog-Vehicular Edge Cloud Architectures
Authors:
Amal A. Alahmadi,
T. E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
This paper investigates distributed processing in Vehicular Edge Cloud (VECs), where a group of vehicles in a car park, at a charging station or at a road traffic intersection, cluster and form a temporary vehicular cloud by combining their computational resources in the cluster. We investigated the problem of energy efficient processing task allocation in VEC by develo** a Mixed Integer Linear…
▽ More
This paper investigates distributed processing in Vehicular Edge Cloud (VECs), where a group of vehicles in a car park, at a charging station or at a road traffic intersection, cluster and form a temporary vehicular cloud by combining their computational resources in the cluster. We investigated the problem of energy efficient processing task allocation in VEC by develo** a Mixed Integer Linear Programming (MILP) model to minimize power consumption by optimizing the allocation of different processing tasks to the available network resources, cloud resources, fog resources and vehicular processing nodes resources. Three dimensions of processing allocation were investigated. The first dimension compared centralized processing (in the central cloud) to distributed processing (in the multi-layer fog nodes). The second dimension introduced opportunistic processing in the vehicular nodes with low and high vehicular node density. The third dimension considered non-splittable tasks (single allocation) versus splittable tasks (distributed allocation), representing real-time versus non real-time applications respectively. The results revealed that a power savings up to 70% can be achieved by allocating processing to the vehicles. However, many factors have an impact on the power saving such the vehicle processing capacities, vehicles density, workload size, and the number of generated tasks. It was observed that the power saving is improved by exploiting the flexibility offered by task splitting among the available vehicles.
△ Less
Submitted 25 June, 2020;
originally announced June 2020.
-
Fogbanks: Future Dynamic Vehicular Fog Banks for Processing, Sensing and Storage in 6G
Authors:
A. A. Alahmadi,
M. O. I. Musa,
T. E. H. El-Gorashi,
J. M. H. Elmirghani,
S. Grant-Muller,
D. Hutchison,
A. Mauthe,
M. Dianati,
C. Maple,
L. Lefevre,
A. Lason
Abstract:
Fixed edge processing has become a key feature of 5G networks, while playing a key role in reducing latency, improving energy efficiency and introducing flexible compute resource utilization on-demand with added cost savings. Autonomous vehicles are expected to possess significantly more on-board processing capabilities and with improved connectivity. Vehicles continue to be used for a fraction of…
▽ More
Fixed edge processing has become a key feature of 5G networks, while playing a key role in reducing latency, improving energy efficiency and introducing flexible compute resource utilization on-demand with added cost savings. Autonomous vehicles are expected to possess significantly more on-board processing capabilities and with improved connectivity. Vehicles continue to be used for a fraction of the day, and as such there is a potential to increase processing capacity by utilizing these resources while vehicles are in short-term and long-term car parks, in roads and at road intersections. Such car parks and road segments can be transformed, through 6G networks, into vehicular fog clusters, or Fogbanks, that can provide processing, storage and sensing capabilities, making use of underutilized vehicular resources. We introduce the Fogbanks concept, outline current research efforts underway in vehicular clouds, and suggest promising directions for 6G in a world where autonomous driving will become commonplace. Moreover, we study the processing allocation problem in cloud-based Fogbank architecture. We solve this problem using Mixed Integer Programming (MILP) to minimize the total power consumption of the proposed architecture, taking into account two allocation strategies, single allocation of tasks and distributed allocation. Finally, we describe additional future directions needed to establish reliability, security, virtualisation, energy efficiency, business models and standardization.
△ Less
Submitted 10 May, 2020;
originally announced May 2020.
-
VM placement over WDM-TDM AWGR PON Based Data Centre Architecture
Authors:
Azza E. A. Eltraify,
Sanaa Hamid Mohamed,
Jaafar M. H. Elmirghani
Abstract:
Passive optical networks (PON) can play a vital role in data centres and access fog solutions by providing scalable, cost and energy efficient architectures. This paper proposes a Mixed Integer Linear Programming (MILP) model to optimize the placement of virtual machines (VMs) over an energy efficient WDM-TDM AWGR PON based data centre architecture. In this optimization, the use of VMs and their r…
▽ More
Passive optical networks (PON) can play a vital role in data centres and access fog solutions by providing scalable, cost and energy efficient architectures. This paper proposes a Mixed Integer Linear Programming (MILP) model to optimize the placement of virtual machines (VMs) over an energy efficient WDM-TDM AWGR PON based data centre architecture. In this optimization, the use of VMs and their requirements affect the optimum number of servers utilized in the data centre when minimizing the power consumption and enabling more efficient utilization of servers is considered. Two power consumption minimization objectives were examined for up to 20 VMs with different computing and networking requirements. The results indicate that considering the minimization of the processing and networking power consumption in the allocation of VMs in the WDM-TDM AWGR PON can reduce the networking power consumption by up to 70% compared to the minimization of the processing power consumption.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Caching Video-on-Demand in Metro and Access Fog Data Centres
Authors:
Wafaa B. M. Fadlelmula,
Sanaa Hamid Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
This paper examines the utilization of metro fog data centres and access fog datacentres with integrated solar cells and Energy Storage Devices (ESDs) to assist cloud data centres in caching Video-on-Demand content and hence, reduce the networking power consumption. A Mixed Integer Linear Programming (MILP) model is used to optimize the delivery of the content from cloud, metro fog, or access fog…
▽ More
This paper examines the utilization of metro fog data centres and access fog datacentres with integrated solar cells and Energy Storage Devices (ESDs) to assist cloud data centres in caching Video-on-Demand content and hence, reduce the networking power consumption. A Mixed Integer Linear Programming (MILP) model is used to optimize the delivery of the content from cloud, metro fog, or access fog datacentres. The results for a range of data centre parameters show that savings by up to 38% in the transport network power consumption can be achieved when VoD is optimally served from fully renewable-powered cloud or metro fog data centres or from access fog data centres with 250 m2 solar cells. Additional 8% savings can be achieved when using ESDs of 100 kWh capacity in the access fog data centres.
△ Less
Submitted 6 May, 2020;
originally announced May 2020.
-
Evaluation of Applications Latency in Server Centric Passive Optical Network Based Data Centre Architectures
Authors:
Azza E. A. Eltraify,
Mohamed O. I. Musa,
Ahmed Al-Quzweeni,
Jaafar M. H. Elmirghani
Abstract:
The number of applications running in the cloud has dramatically increased in the past decade as well as the number of users accessing them. Data centres resources, architectures and conditions define the performance of the applications running on them. One of the main measures of the network efficiency is the latency, which can have a huge effect on resources utilisation, power consumption and th…
▽ More
The number of applications running in the cloud has dramatically increased in the past decade as well as the number of users accessing them. Data centres resources, architectures and conditions define the performance of the applications running on them. One of the main measures of the network efficiency is the latency, which can have a huge effect on resources utilisation, power consumption and the overall performance. In this paper, the performance of a fog network is evaluated by measuring the latency while running a facial recognition software. The network consists of two processing cells, a core network and a PON cell. The results show how network latency is affected by running the facial recognition software in the end-to-end network setup introduced in this paper.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
NOMA Visible Light Communication System with Angle Diversity Receivers
Authors:
Mansourah K. Aljohani,
Osama Zwaid Alsulami,
Khulood D. Alazwary,
Mohamed O. I. Musa,
T. E. H. El-Gorashi,
Mohammed T. Alresheedi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, a non-orthogonal multiple access (NOMA) visible light communication (VLC) system is investigated. The system uses angle diversity receivers (ADRs) to provide high data rates. The ADR has 4 branches, each directed to a different direction. An 8m x 4m sized room is modelled to study the resource allocation to users according to their channel conditions to maximize the data rate. The r…
▽ More
In this paper, a non-orthogonal multiple access (NOMA) visible light communication (VLC) system is investigated. The system uses angle diversity receivers (ADRs) to provide high data rates. The ADR has 4 branches, each directed to a different direction. An 8m x 4m sized room is modelled to study the resource allocation to users according to their channel conditions to maximize the data rate. The results show that using ADRs improves the data rate by an average of 35% compared to a system using wide FOV receivers.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
Impact of user distribution on optical wireless systems
Authors:
Khulood D. Alazwary,
Osama Zwaid Alsulami,
Sarah O. M. Saeed,
Sanaa Hamid Mohamed,
T. E. H. El-Gorashi,
Mohammed T. Alresheedi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, we investigate the impact of user distribution on resource allocation in visible light communication (VLC) systems, using a wavelength division multiple access (WDMA) scheme. Two different room layouts are examined in this study. Three 10-user scenarios are considered, while an optical angle diversity receiver (ADR) with four faces is used. A mixed-integer linear programming (MILP)…
▽ More
In this paper, we investigate the impact of user distribution on resource allocation in visible light communication (VLC) systems, using a wavelength division multiple access (WDMA) scheme. Two different room layouts are examined in this study. Three 10-user scenarios are considered, while an optical angle diversity receiver (ADR) with four faces is used. A mixed-integer linear programming (MILP) model is utilized to identify the optimum wavelengths and access point (AP) allocation in each scenario. The results show that a change in user distribution can affect the level of channel bandwidth and SINR. However, a uniform distribution of users in the room can provide a higher channel bandwidth as well as high SINR above the threshold (15.6 dB) for all users compared to clustered users, which is a scenario that has the lowest SINR with supported data rate above 3.2 Gbps.
△ Less
Submitted 4 May, 2020;
originally announced May 2020.
-
Standards for Energy Efficient Virtualization, Content Distribution and Big Data in Beyond 5G Networks
Authors:
Jaafar M. H. Elmirghani,
Hatem Alharbi,
Azza Eltraify,
Sanaa Hamid Mohamed,
Barzan A. Yosuf,
Taisir E. H. El-Gorashi
Abstract:
Power consumption in communication networks and the supporting computing systems continues to increase due to the increase in traffic and processing requirements, and due to the relatively slower improvements in energy efficiency. Future networks are expected to continue to move computing algorithms and capabilities into the network including increased use of analytics, machine learning and intell…
▽ More
Power consumption in communication networks and the supporting computing systems continues to increase due to the increase in traffic and processing requirements, and due to the relatively slower improvements in energy efficiency. Future networks are expected to continue to move computing algorithms and capabilities into the network including increased use of analytics, machine learning and intelligence applied to big data in the network, with content caching and virtualization. This article summarizes the key features of five new IEEE standards currently being developed to improve the energy efficiency of networks beyond 5G.
△ Less
Submitted 4 May, 2020;
originally announced May 2020.
-
Data center top of rack switch to multiple spine switches optical wireless uplinks
Authors:
Abrar S. Alhazmi,
Osama Zwaid Alsulami,
T. E. H. El-Gorashi,
Mohammed T. Alresheedi,
Jaafar M. H. Elmirghani
Abstract:
Infrared (IR) uplinks can achieve high data rates, which are essential in a range of applications. This paper introduces a novel approach to enable data centre uplink communication. We introduce a novel method to enable communication between racks and spine switches. In our proposed data centre, we consider three racks, each of which has its own angle diversity transmitter (ADT) that is located on…
▽ More
Infrared (IR) uplinks can achieve high data rates, which are essential in a range of applications. This paper introduces a novel approach to enable data centre uplink communication. We introduce a novel method to enable communication between racks and spine switches. In our proposed data centre, we consider three racks, each of which has its own angle diversity transmitter (ADT) that is located on top of the rack. Four wide field of view receivers are fixed to the ceiling of the data centre. Each such receiver is connected to a spine switch. We evaluate the performance of our proposed system when each link operates at a data rate above 2.8 Gb/s. Multiple links can be used to achieve higher data rates using the space or wavelength dimensions. The results show that our proposed system has the ability to work at a high data rate with good performance while using simple on-off-keying.
△ Less
Submitted 3 May, 2020;
originally announced May 2020.
-
Energy Efficient Neural Network Embedding in IoT over Passive Optical Networks
Authors:
Mohammed Moawad Alenazi,
Barzan A. Yosuf,
Taisir El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
In the near future, IoT based application services are anticipated to collect massive amounts of data on which complex and diverse tasks are expected to be performed. Machine learning algorithms such as Artificial Neural Networks (ANN) are increasingly used in smart environments to predict the output for a given problem based on a set of tuning parameters as the input. To this end, we present an e…
▽ More
In the near future, IoT based application services are anticipated to collect massive amounts of data on which complex and diverse tasks are expected to be performed. Machine learning algorithms such as Artificial Neural Networks (ANN) are increasingly used in smart environments to predict the output for a given problem based on a set of tuning parameters as the input. To this end, we present an energy efficient neural network (EE-NN) service embedding framework for IoT based smart homes. The developed framework considers the idea of Service Oriented Architecture (SOA) to provide service abstraction for multiple complex modules of a NN which can be used by a higher application layer. We utilize Mixed Integer Linear Programming (MILP) to formulate the embedding problem to minimize the total power consumption of networking and processing simultaneously. The results of the MILP model show that our optimized NN can save up to 86% by embedding processing modules in IoT devices and up to 72% in fog nodes due to the limited capacity of IoT devices.
△ Less
Submitted 2 May, 2020;
originally announced May 2020.
-
PON-based connectivity for fog computing
Authors:
Abdullah M. Alqahtani,
Sanaa H. Mohamed,
Taisir E. H. El-Gorashi,
Jaafar M. H. Elmirghani
Abstract:
Fog computing plays a crucial role in satisfying the requirements of delay-sensitive applications such as connected vehicles, smart grids, and actuator networks by moving data processing close to end users. Passive optical networks (PONs) are widely used in access networks to reduce the power consumption while providing high bandwidth to end users under flexible designs. Typically, distributed fog…
▽ More
Fog computing plays a crucial role in satisfying the requirements of delay-sensitive applications such as connected vehicles, smart grids, and actuator networks by moving data processing close to end users. Passive optical networks (PONs) are widely used in access networks to reduce the power consumption while providing high bandwidth to end users under flexible designs. Typically, distributed fog computing units in access networks have limited processing and storage capacities that can be under or over utilized depending on instantaneous demands. To extend the available capacity in access network, this paper proposes a fog computing architecture based on SDN-enabled PONs to achieve full connectivity among distributed fog computing servers. The power consumption results show that this architecture can achieve up to about 80% power savings in comparison to legacy fog computing based on spine and leaf data centers with the same number of servers.
△ Less
Submitted 2 May, 2020;
originally announced May 2020.