Two-Stage Deep Learning Framework for Quality Assessment of Left Atrial Late Gadolinium Enhanced MRI Images
Authors:
K M Arefeen Sultan,
Benjamin Orkild,
Alan Morris,
Eugene Kholmovski,
Erik Bieging,
Eugene Kwan,
Ravi Ranjan,
Ed DiBella,
Shireen Elhabian
Abstract:
Accurate assessment of left atrial fibrosis in patients with atrial fibrillation relies on high-quality 3D late gadolinium enhancement (LGE) MRI images. However, obtaining such images is challenging due to patient motion, changing breathing patterns, or sub-optimal choice of pulse sequence parameters. Automated assessment of LGE-MRI image diagnostic quality is clinically significant as it would en…
▽ More
Accurate assessment of left atrial fibrosis in patients with atrial fibrillation relies on high-quality 3D late gadolinium enhancement (LGE) MRI images. However, obtaining such images is challenging due to patient motion, changing breathing patterns, or sub-optimal choice of pulse sequence parameters. Automated assessment of LGE-MRI image diagnostic quality is clinically significant as it would enhance diagnostic accuracy, improve efficiency, ensure standardization, and contributes to better patient outcomes by providing reliable and high-quality LGE-MRI scans for fibrosis quantification and treatment planning. To address this, we propose a two-stage deep-learning approach for automated LGE-MRI image diagnostic quality assessment. The method includes a left atrium detector to focus on relevant regions and a deep network to evaluate diagnostic quality. We explore two training strategies, multi-task learning, and pretraining using contrastive learning, to overcome limited annotated data in medical imaging. Contrastive Learning result shows about $4\%$, and $9\%$ improvement in F1-Score and Specificity compared to Multi-Task learning when there's limited data.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI
Authors:
Sajan Goud Lingala,
Edward DiBella,
Mathews Jacob
Abstract:
We propose a novel deformation corrected compressed sensing (DC-CS) framework to recover dynamic magnetic resonance images from undersampled measurements. We introduce a generalized formulation that is capable of handling a wide class of sparsity/compactness priors on the deformation corrected dynamic signal. In this work, we consider example compactness priors such as sparsity in temporal Fourier…
▽ More
We propose a novel deformation corrected compressed sensing (DC-CS) framework to recover dynamic magnetic resonance images from undersampled measurements. We introduce a generalized formulation that is capable of handling a wide class of sparsity/compactness priors on the deformation corrected dynamic signal. In this work, we consider example compactness priors such as sparsity in temporal Fourier domain, sparsity in temporal finite difference domain, and nuclear norm penalty to exploit low rank structure. Using variable splitting, we decouple the complex optimization problem to simpler and well understood sub problems; the resulting algorithm alternates between simple steps of shrinkage based denoising, deformable registration, and a quadratic optimization step. Additionally, we employ efficient continuation strategies to minimize the risk of convergence to local minima. The proposed formulation contrasts with existing DC-CS schemes that are customized for free breathing cardiac cine applications, and other schemes that rely on fully sampled reference frames or navigator signals to estimate the deformation parameters. The efficient decoupling enabled by the proposed scheme allows its application to a wide range of applications including contrast enhanced dynamic MRI. Through experiments on numerical phantom and in vivo myocardial perfusion MRI datasets, we demonstrate the utility of the proposed DC-CS scheme in providing robust reconstructions with reduced motion artifacts over classical compressed sensing schemes that utilize the compact priors on the original deformation un-corrected signal.
△ Less
Submitted 2 September, 2014; v1 submitted 29 May, 2014;
originally announced May 2014.