Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking
Authors:
Miha Dezman,
Charlotte Marquardt,
Adnan Ugur,
Tamim Asfour
Abstract:
Exoskeleton devices impose kinematic constraints on a user's motion and affect their stability due to added mass but also due to the simplified mechanical design. This paper investigates how these constraints resulting from simplified mechanical designs impact the gait kinematics and stability of users by wearing an ankle exoskeleton with changeable degree of freedom (DoF). The exoskeleton used in…
▽ More
Exoskeleton devices impose kinematic constraints on a user's motion and affect their stability due to added mass but also due to the simplified mechanical design. This paper investigates how these constraints resulting from simplified mechanical designs impact the gait kinematics and stability of users by wearing an ankle exoskeleton with changeable degree of freedom (DoF). The exoskeleton used in this paper allows one, two, or three DoF at the ankle, simulating different levels of mechanical complexity. This effect was evaluated in a pilot study consisting of six participants walking on a straight path. The results show that increasing the exoskeleton DoF results in an improvement of several metrics, including kinematics and gait parameters. The transition from 1 DoF to 2 DoF is shown to have a larger effect than the transition from 2 DoF to 3 DoF for an ankle exoskeleton. However, an exoskeleton with 3 DoF at the ankle featured the best results. Increasing the number of DoF resulted in stability values closer the values when walking without the exoskeleton, despite the added weight of the exoskeleton.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
The JSI-KneExo: Active, Quasi-Passive, Pneumatic, Portable Knee Exo with Bidirectional Energy Flow for Air Recovery in Sit-Stand Tasks
Authors:
Luka Mišković,
Tilen Brecelj,
Miha Dežman,
Tadej Petrič
Abstract:
While existing literature encompasses exoskeleton-assisted sit-stand tasks, the integration of energy recovery mechanisms remains unexplored. To push these boundaries further, this study introduces a portable pneumatic knee exoskeleton that operates in both quasi-passive and active modes, where active mode is utilized for aiding in standing up (power generation), thus the energy flows from the exo…
▽ More
While existing literature encompasses exoskeleton-assisted sit-stand tasks, the integration of energy recovery mechanisms remains unexplored. To push these boundaries further, this study introduces a portable pneumatic knee exoskeleton that operates in both quasi-passive and active modes, where active mode is utilized for aiding in standing up (power generation), thus the energy flows from the exoskeleton to the user, and quasi-passive mode for aiding in sitting down (power absorption), where the device absorbs and can store energy in the form of compressed air, leading to energy savings in active mode. The absorbed energy can be stored and later reused without compromising exoskeleton transparency in the meantime. In active mode, a small air pump inflates the pneumatic artificial muscle (PAM), which stores the compressed air, that can then be released into a pneumatic cylinder to generate torque. All electronic and pneumatic components are integrated into the system, and the exoskeleton weighs 3.9 kg with a maximum torque of 20 Nm at the knee joint. The paper describes the mechatronic design, mathematical model and includes a pilot study with an able-bodied subject performing sit-to-stand tasks. The results show that the exoskeleton can recover energy while assisting the subject and reducing muscle activity. Furthermore, results underscore air regeneration's impact on energy-saving in portable pneumatic exoskeletons.
△ Less
Submitted 6 September, 2023; v1 submitted 28 June, 2023;
originally announced June 2023.