-
Towards Robotic Knee Arthroscopy: Multi-Scale Network for Tissue-Tool Segmentation
Authors:
Shahnewaz Ali,
Prof. Ross Crawford,
Dr. Frederic Maire,
Assoc. Prof. Ajay K. Pandey
Abstract:
Tissue awareness has a great demand to improve surgical accuracy in minimally invasive procedures. In arthroscopy, it is one of the challenging tasks due to surgical sites exhibit limited features and textures. Moreover, arthroscopic surgical video shows high intra-class variations. Arthroscopic videos are recorded with endoscope known as arthroscope which records tissue structures at proximity, t…
▽ More
Tissue awareness has a great demand to improve surgical accuracy in minimally invasive procedures. In arthroscopy, it is one of the challenging tasks due to surgical sites exhibit limited features and textures. Moreover, arthroscopic surgical video shows high intra-class variations. Arthroscopic videos are recorded with endoscope known as arthroscope which records tissue structures at proximity, therefore, frames contain minimal joint structure. As consequences, fully conventional network-based segmentation model suffers from long- and short- term dependency problems. In this study, we present a densely connected shape aware multi-scale segmentation model which captures multi-scale features and integrates shape features to achieve tissue-tool segmentations. The model has been evaluated with three distinct datasets. Moreover, with the publicly available polyp dataset our proposed model achieved 5.09 % accuracy improvement.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
Surgery Scene Restoration for Robot Assisted Minimally Invasive Surgery
Authors:
Shahnewaz Ali,
Yaqub Jonmohamadi,
Ross Crawford,
Davide Fontanarosa,
Ajay K. Pandey
Abstract:
Minimally invasive surgery (MIS) offers several advantages including minimum tissue injury and blood loss, and quick recovery time, however, it imposes some limitations on surgeons ability. Among others such as lack of tactile or haptic feedback, poor visualization of the surgical site is one of the most acknowledged factors that exhibits several surgical drawbacks including unintentional tissue d…
▽ More
Minimally invasive surgery (MIS) offers several advantages including minimum tissue injury and blood loss, and quick recovery time, however, it imposes some limitations on surgeons ability. Among others such as lack of tactile or haptic feedback, poor visualization of the surgical site is one of the most acknowledged factors that exhibits several surgical drawbacks including unintentional tissue damage. To the context of robot assisted surgery, lack of frame contextual details makes vision task challenging when it comes to tracking tissue and tools, segmenting scene, and estimating pose and depth. In MIS the acquired frames are compromised by different noises and get blurred caused by motions from different sources. Moreover, when underwater environment is considered for instance knee arthroscopy, mostly visible noises and blur effects are originated from the environment, poor control on illuminations and imaging conditions. Additionally, in MIS, procedure like automatic white balancing and transformation between the raw color information to its standard RGB color space are often absent due to the hardware miniaturization. There is a high demand of an online preprocessing framework that can circumvent these drawbacks. Our proposed method is able to restore a latent clean and sharp image in standard RGB color space from its noisy, blur and raw observation in a single preprocessing stage.
△ Less
Submitted 6 September, 2021;
originally announced September 2021.
-
3D Semantic Map** from Arthroscopy using Out-of-distribution Pose and Depth and In-distribution Segmentation Training
Authors:
Yaqub Jonmohamadi,
Shahnewaz Ali,
Fengbei Liu,
Jonathan Roberts,
Ross Crawford,
Gustavo Carneiro,
Ajay K. Pandey
Abstract:
Minimally invasive surgery (MIS) has many documented advantages, but the surgeon's limited visual contact with the scene can be problematic. Hence, systems that can help surgeons navigate, such as a method that can produce a 3D semantic map, can compensate for the limitation above. In theory, we can borrow 3D semantic map** techniques developed for robotics, but this requires finding solutions t…
▽ More
Minimally invasive surgery (MIS) has many documented advantages, but the surgeon's limited visual contact with the scene can be problematic. Hence, systems that can help surgeons navigate, such as a method that can produce a 3D semantic map, can compensate for the limitation above. In theory, we can borrow 3D semantic map** techniques developed for robotics, but this requires finding solutions to the following challenges in MIS: 1) semantic segmentation, 2) depth estimation, and 3) pose estimation. In this paper, we propose the first 3D semantic map** system from knee arthroscopy that solves the three challenges above. Using out-of-distribution non-human datasets, where pose could be labeled, we jointly train depth+pose estimators using selfsupervised and supervised losses. Using an in-distribution human knee dataset, we train a fully-supervised semantic segmentation system to label arthroscopic image pixels into femur, ACL, and meniscus. Taking testing images from human knees, we combine the results from these two systems to automatically create 3D semantic maps of the human knee. The result of this work opens the pathway to the generation of intraoperative 3D semantic map**, registration with pre-operative data, and robotic-assisted arthroscopy
△ Less
Submitted 10 June, 2021;
originally announced June 2021.
-
Arthroscopic Multi-Spectral Scene Segmentation Using Deep Learning
Authors:
Shahnewaz Ali,
Dr. Yaqub Jonmohamadi,
Yu Takeda,
Jonathan Roberts,
Ross Crawford,
Cameron Brown,
Dr. Ajay K. Pandey
Abstract:
Knee arthroscopy is a minimally invasive surgical (MIS) procedure which is performed to treat knee-joint ailment. Lack of visual information of the surgical site obtained from miniaturized cameras make this surgical procedure more complex. Knee cavity is a very confined space; therefore, surgical scenes are captured at close proximity. Insignificant context of knee atlas often makes them unrecogni…
▽ More
Knee arthroscopy is a minimally invasive surgical (MIS) procedure which is performed to treat knee-joint ailment. Lack of visual information of the surgical site obtained from miniaturized cameras make this surgical procedure more complex. Knee cavity is a very confined space; therefore, surgical scenes are captured at close proximity. Insignificant context of knee atlas often makes them unrecognizable as a consequence unintentional tissue damage often occurred and shows a long learning curve to train new surgeons. Automatic context awareness through labeling of the surgical site can be an alternative to mitigate these drawbacks. However, from the previous studies, it is confirmed that the surgical site exhibits several limitations, among others, lack of discriminative contextual information such as texture and features which drastically limits this vision task. Additionally, poor imaging conditions and lack of accurate ground-truth labels are also limiting the accuracy. To mitigate these limitations of knee arthroscopy, in this work we proposed a scene segmentation method that successfully segments multi structures.
△ Less
Submitted 3 March, 2021;
originally announced March 2021.
-
A deep learning-facilitated radiomics solution for the prediction of lung lesion shrinkage in non-small cell lung cancer trials
Authors:
Antong Chen,
Jennifer Saouaf,
Bo Zhou,
Randolph Crawford,
Jianda Yuan,
Junshui Ma,
Richard Baumgartner,
Shubing Wang,
Gregory Goldmacher
Abstract:
Herein we propose a deep learning-based approach for the prediction of lung lesion response based on radiomic features extracted from clinical CT scans of patients in non-small cell lung cancer trials. The approach starts with the classification of lung lesions from the set of primary and metastatic lesions at various anatomic locations. Focusing on the lung lesions, we perform automatic segmentat…
▽ More
Herein we propose a deep learning-based approach for the prediction of lung lesion response based on radiomic features extracted from clinical CT scans of patients in non-small cell lung cancer trials. The approach starts with the classification of lung lesions from the set of primary and metastatic lesions at various anatomic locations. Focusing on the lung lesions, we perform automatic segmentation to extract their 3D volumes. Radiomic features are then extracted from the lesion on the pre-treatment scan and the first follow-up scan to predict which lesions will shrink at least 30% in diameter during treatment (either Pembrolizumab or combinations of chemotherapy and Pembrolizumab), which is defined as a partial response by the Response Evaluation Criteria In Solid Tumors (RECIST) guidelines. A 5-fold cross validation on the training set led to an AUC of 0.84 +/- 0.03, and the prediction on the testing dataset reached AUC of 0.73 +/- 0.02 for the outcome of 30% diameter shrinkage.
△ Less
Submitted 5 March, 2020;
originally announced March 2020.
-
Real-time Joint Motion Analysis and Instrument Tracking for Robot-Assisted Orthopaedic Surgery
Authors:
Mario Strydom,
Artur Banach,
Liao Wu,
Ross Crawford,
Jonathan Roberts,
Anjali Jaiprakash
Abstract:
Robotic-assisted orthopaedic surgeries demand accurate, automated leg manipulation for improved spatial accuracy to reduce iatrogenic damage. In this study, we propose novel rigid body designs and an optical tracking volume setup for tracking of the femur, tibia and surgical instruments. Anatomical points inside the leg are measured using Computed Tomography with an accuracy of 0.3mm. Combined wit…
▽ More
Robotic-assisted orthopaedic surgeries demand accurate, automated leg manipulation for improved spatial accuracy to reduce iatrogenic damage. In this study, we propose novel rigid body designs and an optical tracking volume setup for tracking of the femur, tibia and surgical instruments. Anatomical points inside the leg are measured using Computed Tomography with an accuracy of 0.3mm. Combined with kinematic modelling, we can express these points relative to any frame and across joints to sub-millimetre accuracy. It enables the setup of vectors on the mechanical axes of the femur and tibia for kinematic analysis. Cadaveric experiments are used to verify the tracking of internal anatomies and joint motion analysis. The proposed integrated solution is a first step in the automation of leg manipulation and can be used as a ground-truth for future robot-assisted orthopaedic research.
△ Less
Submitted 6 September, 2019;
originally announced September 2019.
-
Geometric interpretation of the general POE model for a serial-link robot via conversion into D-H parameterization
Authors:
Liao Wu,
Ross Crawford,
Jonathan Roberts
Abstract:
While Product of Exponentials (POE) formula has been gaining increasing popularity in modeling the kinematics of a serial-link robot, the Denavit-Hartenberg (D-H) notation is still the most widely used due to its intuitive and concise geometric interpretation of the robot. This paper has developed an analytical solution to automatically convert a POE model into a D-H model for a robot with revolut…
▽ More
While Product of Exponentials (POE) formula has been gaining increasing popularity in modeling the kinematics of a serial-link robot, the Denavit-Hartenberg (D-H) notation is still the most widely used due to its intuitive and concise geometric interpretation of the robot. This paper has developed an analytical solution to automatically convert a POE model into a D-H model for a robot with revolute, prismatic, and helical joints, which are the complete set of three basic one degree of freedom lower pair joints for constructing a serial-link robot. The conversion algorithm developed can be used in applications such as calibration where it is necessary to convert the D-H model to the POE model for identification and then back to the D-H model for compensation. The equivalence of the two models proved in this paper also benefits the analysis of the identifiability of the kinematic parameters. It is found that the maximum number of identifiable parameters in a general POE model is 5h+4r +2t +n+6 where h, r, t, and n stand for the number of helical, revolute, prismatic, and general joints, respectively. It is also suggested that the identifiability of the base frame and the tool frame in the D-H model is restricted rather than the arbitrary six parameters as assumed previously.
△ Less
Submitted 25 January, 2024; v1 submitted 1 February, 2019;
originally announced February 2019.
-
A Progressively-trained Scale-invariant and Boundary-aware Deep Neural Network for the Automatic 3D Segmentation of Lung Lesions
Authors:
Bo Zhou,
Randolph Crawford,
Belma Dogdas,
Gregory Goldmacher,
Antong Chen
Abstract:
Volumetric segmentation of lesions on CT scans is important for many types of analysis, including lesion growth kinetic modeling in clinical trials and machine learning of radiomic features. Manual segmentation is laborious, and impractical for large-scale use. For routine clinical use, and in clinical trials that apply the Response Evaluation Criteria In Solid Tumors (RECIST), clinicians typicall…
▽ More
Volumetric segmentation of lesions on CT scans is important for many types of analysis, including lesion growth kinetic modeling in clinical trials and machine learning of radiomic features. Manual segmentation is laborious, and impractical for large-scale use. For routine clinical use, and in clinical trials that apply the Response Evaluation Criteria In Solid Tumors (RECIST), clinicians typically outline the boundaries of a lesion on a single slice to extract diameter measurements. In this work, we have collected a large-scale database, named LesionVis, with pixel-wise manual 2D lesion delineations on the RECIST-slices. To extend the 2D segmentations to 3D, we propose a volumetric progressive lesion segmentation (PLS) algorithm to automatically segment the 3D lesion volume from 2D delineations using a scale-invariant and boundary-aware deep convolutional network (SIBA-Net). The SIBA-Net copes with the size transition of a lesion when the PLS progresses from the RECIST-slice to the edge-slices, as well as when performing longitudinal assessment of lesions whose size change over multiple time points. The proposed PLS-SiBA-Net (P-SiBA) approach is assessed on the lung lesion cases from LesionVis. Our experimental results demonstrate that the P-SiBA approach achieves mean Dice similarity coefficients (DSC) of 0.81, which significantly improves 3D segmentation accuracy compared with the approaches proposed previously (highest mean DSC at 0.78 on LesionVis). In summary, by leveraging the limited 2D delineations on the RECIST-slices, P-SiBA is an effective semi-supervised approach to produce accurate lesion segmentations in 3D.
△ Less
Submitted 11 November, 2018;
originally announced November 2018.