-
Scalable and RISC-V Programmable Near-Memory Computing Architectures for Edge Nodes
Authors:
Michele Caon,
Clément Choné,
Pasquale Davide Schiavone,
Alexandre Levisse,
Guido Masera,
Maurizio Martina,
David Atienza
Abstract:
The widespread adoption of data-centric algorithms, particularly Artificial Intelligence (AI) and Machine Learning (ML), has exposed the limitations of centralized processing infrastructures, driving a shift towards edge computing. This necessitates stringent constraints on energy efficiency, which traditional von Neumann architectures struggle to meet. The Compute-In-Memory (CIM) paradigm has eme…
▽ More
The widespread adoption of data-centric algorithms, particularly Artificial Intelligence (AI) and Machine Learning (ML), has exposed the limitations of centralized processing infrastructures, driving a shift towards edge computing. This necessitates stringent constraints on energy efficiency, which traditional von Neumann architectures struggle to meet. The Compute-In-Memory (CIM) paradigm has emerged as a superior candidate due to its efficient exploitation of available memory bandwidth. However, existing CIM solutions require high implementation effort and lack flexibility from a software integration standpoint. This work proposes a novel, software-friendly, general-purpose, and low-integration-effort Near-Memory Computing (NMC) approach, paving the way for the adoption of CIM-based systems in the next generation of edge computing nodes. Two architectural variants, NM-Caesar and NM-Carus, are proposed and characterized to target different trade-offs in area efficiency, performance, and flexibility, covering a wide range of embedded microcontrollers. Post-layout simulations show up to $25.8\times$ and $50.0\times$ lower execution time and $23.2\times$ and $33.1\times$ higher energy efficiency at the system level, respectively, compared to executing the same tasks on a state-of-the-art RISC-V CPU (RV32IMC). NM-Carus achieves a peak energy efficiency of $306.7$ GOPS/W in 8-bit matrix multiplications, surpassing recent state-of-the-art in- and near-memory circuits.
△ Less
Submitted 20 June, 2024;
originally announced June 2024.
-
ATOMMIC: An Advanced Toolbox for Multitask Medical Imaging Consistency to facilitate Artificial Intelligence applications from acquisition to analysis in Magnetic Resonance Imaging
Authors:
Dimitrios Karkalousos,
Ivana Išgum,
Henk A. Marquering,
Matthan W. A. Caan
Abstract:
AI is revolutionizing MRI along the acquisition and processing chain. Advanced AI frameworks have been developed to apply AI in various successive tasks, such as image reconstruction, quantitative parameter map estimation, and image segmentation. Existing frameworks are often designed to perform tasks independently or are focused on specific models or datasets, limiting generalization. We introduc…
▽ More
AI is revolutionizing MRI along the acquisition and processing chain. Advanced AI frameworks have been developed to apply AI in various successive tasks, such as image reconstruction, quantitative parameter map estimation, and image segmentation. Existing frameworks are often designed to perform tasks independently or are focused on specific models or datasets, limiting generalization. We introduce ATOMMIC, an open-source toolbox that streamlines AI applications for accelerated MRI reconstruction and analysis. ATOMMIC implements several tasks using DL networks and enables MultiTask Learning (MTL) to perform related tasks integrated, targeting generalization in the MRI domain. We first review the current state of AI frameworks for MRI through a comprehensive literature search and by parsing 12,479 GitHub repositories. We benchmark 25 DL models on eight publicly available datasets to present distinct applications of ATOMMIC on accelerated MRI reconstruction, image segmentation, quantitative parameter map estimation, and joint accelerated MRI reconstruction and image segmentation utilizing MTL. Our findings demonstrate that ATOMMIC is the only MTL framework with harmonized complex-valued and real-valued data support. Evaluations on single tasks show that physics-based models, which enforce data consistency by leveraging the physical properties of MRI, outperform other models in reconstructing highly accelerated acquisitions. Physics-based models that produce high reconstruction quality can accurately estimate quantitative parameter maps. When high-performing reconstruction models are combined with robust segmentation networks utilizing MTL, performance is improved in both tasks. ATOMMIC facilitates MRI reconstruction and analysis by standardizing workflows, enhancing data interoperability, integrating unique features like MTL, and effectively benchmarking DL models.
△ Less
Submitted 30 April, 2024;
originally announced April 2024.
-
Deep Learning-based Intraoperative MRI Reconstruction
Authors:
Jon André Ottesen,
Tryggve Storas,
Svein Are Sirirud Vatnehol,
Grethe Løvland,
Einar O. Vik-Mo,
Till Schellhorn,
Karoline Skogen,
Christopher Larsson,
Atle Bjørnerud,
Inge Rasmus Groote-Eindbaas,
Matthan W. A. Caan
Abstract:
Purpose: To evaluate the quality of deep learning reconstruction for prospectively accelerated intraoperative magnetic resonance imaging (iMRI) during resective brain tumor surgery.
Materials and Methods: Accelerated iMRI was performed during brain surgery using dual surface coils positioned around the area of resection. A deep learning (DL) model was trained on the fastMRI neuro dataset to mimi…
▽ More
Purpose: To evaluate the quality of deep learning reconstruction for prospectively accelerated intraoperative magnetic resonance imaging (iMRI) during resective brain tumor surgery.
Materials and Methods: Accelerated iMRI was performed during brain surgery using dual surface coils positioned around the area of resection. A deep learning (DL) model was trained on the fastMRI neuro dataset to mimic the data from the iMRI protocol. Evaluation was performed on imaging material from 40 patients imaged between 01.11.2021 - 01.06.2023 that underwent iMRI during tumor resection surgery. A comparative analysis was conducted between the conventional compressed sense (CS) method and the trained DL reconstruction method. Blinded evaluation of multiple image quality metrics was performed by two working neuro-radiologists and a working neurosurgeon on a 1 to 5 Likert scale (1=non diagnostic, 2=poor, 3=acceptable, 4=good, 5=excellent), and the favored reconstruction variant.
Results: The DL reconstruction was strongly favored or favored over the CS reconstruction for 33/40, 39/40, and 8/40 of cases for reader 1, 2, and 3, respectively. Two of three readers consistently assigned higher ratings for the DL reconstructions, and the DL reconstructions had a higher score than their respective CS counterparts for 72%, 72%, and 14% of the cases for reader 1, 2, and 3, respectively. Still, the DL reconstructions exhibited shortcomings such as a stri** artifact and reduced signal.
Conclusion: DL shows promise to allow for high-quality reconstructions of intraoperative MRI with equal to or improved perceived spatial resolution, signal-to-noise ratio, diagnostic confidence, diagnostic conspicuity, and spatial resolution compared to compressed sense.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
Error Correcting Codes From General Linear Groups
Authors:
Mahir Bilen Can
Abstract:
The parameters of the AG codes on general linear groups are found. The hyperplane sections having the minimum (or maximum) number of rational points are determined.
The parameters of the AG codes on general linear groups are found. The hyperplane sections having the minimum (or maximum) number of rational points are determined.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Smart Journey in Istanbul: A Mobile Application in Smart Cities for Traffic Estimation by Harnessing Time Series
Authors:
Senem Tanberk,
Mustafa Can
Abstract:
In recent decades, mobile applications (apps) have gained enormous popularity. Smart services for smart cities increasingly gain attention. The main goal of the proposed research is to present a new AI-powered mobile application on Istanbul's traffic congestion forecast by using traffic density data. It addresses the research question by using time series approaches (LSTM, Transformer, and XGBoost…
▽ More
In recent decades, mobile applications (apps) have gained enormous popularity. Smart services for smart cities increasingly gain attention. The main goal of the proposed research is to present a new AI-powered mobile application on Istanbul's traffic congestion forecast by using traffic density data. It addresses the research question by using time series approaches (LSTM, Transformer, and XGBoost) based on past data over the traffic load dataset combined with meteorological conditions. Analysis of simulation results on predicted models will be discussed according to performance indicators such as MAPE, MAE, and RMSE. And then, it was observed that the Transformer model made the most accurate traffic prediction. The developed traffic forecasting prototype is expected to be a starting point on future products for a mobile application suitable for citizens' daily use.
△ Less
Submitted 13 December, 2022;
originally announced December 2022.
-
A Densely Interconnected Network for Deep Learning Accelerated MRI
Authors:
Jon Andre Ottesen,
Matthan W. A. Caan,
Inge Rasmus Groote,
Atle Bjørnerud
Abstract:
Objective: To improve accelerated MRI reconstruction through a densely connected cascading deep learning reconstruction framework.
Materials and Methods: A cascading deep learning reconstruction framework (baseline model) was modified by applying three architectural modifications: Input-level dense connections between cascade inputs and outputs, an improved deep learning sub-network, and long-ra…
▽ More
Objective: To improve accelerated MRI reconstruction through a densely connected cascading deep learning reconstruction framework.
Materials and Methods: A cascading deep learning reconstruction framework (baseline model) was modified by applying three architectural modifications: Input-level dense connections between cascade inputs and outputs, an improved deep learning sub-network, and long-range skip-connections between subsequent deep learning networks. An ablation study was performed, where five model configurations were trained on the NYU fastMRI neuro dataset with an end-to-end scheme conjunct on four- and eight-fold acceleration. The trained models were evaluated by comparing their respective structural similarity index measure (SSIM), normalized mean square error (NMSE) and peak signal to noise ratio (PSNR).
Results: The proposed densely interconnected residual cascading network (DIRCN), utilizing all three suggested modifications, achieved a SSIM improvement of 8% and 11% for four- and eight-fold acceleration, respectively. For eight-fold acceleration, the model achieved a 23% decrease in the NMSE when compared to the baseline model. In an ablation study, the individual architectural modifications all contributed to this improvement, by reducing the SSIM and NMSE with approximately 3% and 5% for four-fold acceleration, respectively.
Conclusion: The proposed architectural modifications allow for simple adjustments on an already existing cascading framework to further improve the resulting reconstructions.
△ Less
Submitted 22 May, 2023; v1 submitted 5 July, 2022;
originally announced July 2022.
-
Assessment of Data Consistency through Cascades of Independently Recurrent Inference Machines for fast and robust accelerated MRI reconstruction
Authors:
D. Karkalousos,
S. Noteboom,
H. E. Hulst,
F. M. Vos,
M. W. A. Caan
Abstract:
Machine Learning methods can learn how to reconstruct Magnetic Resonance Images and thereby accelerate acquisition, which is of paramount importance to the clinical workflow. Physics-informed networks incorporate the forward model of accelerated MRI reconstruction in the learning process. With increasing network complexity, robustness is not ensured when reconstructing data unseen during training.…
▽ More
Machine Learning methods can learn how to reconstruct Magnetic Resonance Images and thereby accelerate acquisition, which is of paramount importance to the clinical workflow. Physics-informed networks incorporate the forward model of accelerated MRI reconstruction in the learning process. With increasing network complexity, robustness is not ensured when reconstructing data unseen during training. We aim to embed data consistency (DC) in deep networks while balancing the degree of network complexity. While doing so, we will assess whether either explicit or implicit enforcement of DC in varying network architectures is preferred to optimize performance. We propose a scheme called Cascades of Independently Recurrent Inference Machines (CIRIM) to assess DC through unrolled optimization. Herein we assess DC both implicitly by gradient descent and explicitly by a designed term. Extensive comparison of the CIRIM to CS as well as to other methods is performed: the E2EVN, CascadeNet, KIKINet, LPDNet, RIM, IRIM, and UNet. Models were trained and evaluated on T1-weighted and FLAIR contrast brain data, and T2-weighted knee data. Both 1D and 2D undersampling patterns were evaluated. Robustness was tested by reconstructing 7.5x prospectively undersampled 3D FLAIR MRI data of Multiple Sclerosis (MS) patients with white matter lesions. The CIRIM performed best when implicitly enforcing DC, while the E2EVN required an explicit DC formulation. In reconstructing MS patient data, prospectively acquired with a sampling pattern unseen during model training, the CIRIM maintained lesion contrast while efficiently denoising the images. The CIRIM showed highly promising generalization capabilities maintaining a very fair trade-off between reconstructed image quality and fast reconstruction times, which is crucial in the clinical workflow.
△ Less
Submitted 4 April, 2022; v1 submitted 30 November, 2021;
originally announced November 2021.
-
Effect of Visual Cues on Pointing Tasks in Co-located Augmented Reality Collaboration
Authors:
Lei Chen,
Yilin Liu,
Yue Li,
Lingyun Yu,
BoYu Gao,
Maurizio Caon,
Yong Yue,
Hai-Ning Liang
Abstract:
Visual cues are essential in computer-mediated communication. It is especially important when communication happens in a collaboration scenario that requires focusing several users' attention on aspecific object among other similar ones. This paper explores the effect of visual cues on pointing tasks in co-located Augmented Reality (AR) collaboration. A user study (N = 32, 16 pairs) was conducted…
▽ More
Visual cues are essential in computer-mediated communication. It is especially important when communication happens in a collaboration scenario that requires focusing several users' attention on aspecific object among other similar ones. This paper explores the effect of visual cues on pointing tasks in co-located Augmented Reality (AR) collaboration. A user study (N = 32, 16 pairs) was conducted to compare two types of visual cues: Pointing Line (PL)and Moving Track (MT). Both are head-based visual techniques.Through a series of collaborative pointing tasks on objects with different states (static and dynamic) and density levels (low, mediumand high), the results showed that PL was better on task performance and usability, but MT was rated higher on social presenceand user preference. Based on our results, some design implicationsare provided for pointing tasks in co-located AR collaboration.
△ Less
Submitted 8 October, 2021;
originally announced October 2021.
-
Recurrent Inference Machines as inverse problem solvers for MR relaxometry
Authors:
E. R. Sabidussi,
S. Klein,
M. W. A. Caan,
S. Bazrafkan,
A. J. den Dekker,
J. Sijbers,
W. J. Niessen,
D. H. J. Poot
Abstract:
In this paper, we propose the use of Recurrent Inference Machines (RIMs) to perform T1 and T2 map**. The RIM is a neural network framework that learns an iterative inference process based on the signal model, similar to conventional statistical methods for quantitative MRI (QMRI), such as the Maximum Likelihood Estimator (MLE). This framework combines the advantages of both data-driven and model…
▽ More
In this paper, we propose the use of Recurrent Inference Machines (RIMs) to perform T1 and T2 map**. The RIM is a neural network framework that learns an iterative inference process based on the signal model, similar to conventional statistical methods for quantitative MRI (QMRI), such as the Maximum Likelihood Estimator (MLE). This framework combines the advantages of both data-driven and model-based methods, and, we hypothesize, is a promising tool for QMRI. Previously, RIMs were used to solve linear inverse reconstruction problems. Here, we show that they can also be used to optimize non-linear problems and estimate relaxometry maps with high precision and accuracy. The developed RIM framework is evaluated in terms of accuracy and precision and compared to an MLE method and an implementation of the ResNet. The results show that the RIM improves the quality of estimates compared to the other techniques in Monte Carlo experiments with simulated data, test-retest analysis of a system phantom, and in-vivo scans. Additionally, inference with the RIM is 150 times faster than the MLE, and robustness to (slight) variations of scanning parameters is demonstrated. Hence, the RIM is a promising and flexible method for QMRI. Coupled with an open-source training data generation tool, it presents a compelling alternative to previous methods.
△ Less
Submitted 8 June, 2021;
originally announced June 2021.
-
Toric Codes from Order Polytopes
Authors:
Mahir Bilen Can,
Takayuki Hibi
Abstract:
In this article we investigate a class of linear error correcting codes in relation with the order polytopes. In particular we consider the order polytopes of tree posets and bipartite posets. We calculate the parameters of the associated toric variety codes.
In this article we investigate a class of linear error correcting codes in relation with the order polytopes. In particular we consider the order polytopes of tree posets and bipartite posets. We calculate the parameters of the associated toric variety codes.
△ Less
Submitted 27 July, 2021; v1 submitted 6 February, 2021;
originally announced February 2021.
-
Domain-adaptive Fall Detection Using Deep Adversarial Training
Authors:
Kai-Chun Liu,
Michael Can,
Heng-Cheng Kuo,
Chia-Yeh Hsieh,
Hsiang-Yun Huang,
Chia-Tai Chan,
Yu Tsao
Abstract:
Fall detection (FD) systems are important assistive technologies for healthcare that can detect emergency fall events and alert caregivers. However, it is not easy to obtain large-scale annotated fall events with various specifications of sensors or sensor positions during the implementation of accurate FD systems. Moreover, the knowledge obtained through machine learning has been restricted to ta…
▽ More
Fall detection (FD) systems are important assistive technologies for healthcare that can detect emergency fall events and alert caregivers. However, it is not easy to obtain large-scale annotated fall events with various specifications of sensors or sensor positions during the implementation of accurate FD systems. Moreover, the knowledge obtained through machine learning has been restricted to tasks in the same domain. The mismatch between different domains might hinder the performance of FD systems. Cross-domain knowledge transfer is very beneficial for machine-learning-based FD systems to train a reliable FD model with well-labeled data in new environments. In this study, we propose domain-adaptive fall detection (DAFD) using deep adversarial training (DAT) to tackle cross-domain problems, such as cross-position and cross-configuration. The proposed DAFD can transfer knowledge from the source domain to the target domain by minimizing the domain discrepancy to avoid mismatch problems. The experimental results show that the average F1-score improvement when using DAFD ranges from 1.5% to 7% in the cross-position scenario, and from 3.5% to 12% in the cross-configuration scenario, compared to using the conventional FD model without domain adaptation training. The results demonstrate that the proposed DAFD successfully helps to deal with cross-domain problems and to achieve better detection performance.
△ Less
Submitted 14 June, 2021; v1 submitted 20 December, 2020;
originally announced December 2020.
-
Multi-Coil MRI Reconstruction Challenge -- Assessing Brain MRI Reconstruction Models and their Generalizability to Varying Coil Configurations
Authors:
Youssef Beauferris,
Jonas Teuwen,
Dimitrios Karkalousos,
Nikita Moriakov,
Mattha Caan,
George Yiasemis,
Lívia Rodrigues,
Alexandre Lopes,
Hélio Pedrini,
Letícia Rittner,
Maik Dannecker,
Viktor Studenyak,
Fabian Gröger,
Devendra Vyas,
Shahrooz Faghih-Roohi,
Amrit Kumar Jethi,
Jaya Chandra Raju,
Mohanasankar Sivaprakasam,
Mike Lasby,
Nikita Nogovitsyn,
Wallace Loos,
Richard Frayne,
Roberto Souza
Abstract:
Deep-learning-based brain magnetic resonance imaging (MRI) reconstruction methods have the potential to accelerate the MRI acquisition process. Nevertheless, the scientific community lacks appropriate benchmarks to assess MRI reconstruction quality of high-resolution brain images, and evaluate how these proposed algorithms will behave in the presence of small, but expected data distribution shifts…
▽ More
Deep-learning-based brain magnetic resonance imaging (MRI) reconstruction methods have the potential to accelerate the MRI acquisition process. Nevertheless, the scientific community lacks appropriate benchmarks to assess MRI reconstruction quality of high-resolution brain images, and evaluate how these proposed algorithms will behave in the presence of small, but expected data distribution shifts. The Multi-Coil Magnetic Resonance Image (MC-MRI) Reconstruction Challenge provides a benchmark that aims at addressing these issues, using a large dataset of high-resolution, three-dimensional, T1-weighted MRI scans. The challenge has two primary goals: 1) to compare different MRI reconstruction models on this dataset and 2) to assess the generalizability of these models to data acquired with a different number of receiver coils. In this paper, we describe the challenge experimental design, and summarize the results of a set of baseline and state of the art brain MRI reconstruction models. We provide relevant comparative information on the current MRI reconstruction state-of-the-art and highlight the challenges of obtaining generalizable models that are required prior to broader clinical adoption. The MC-MRI benchmark data, evaluation code and current challenge leaderboard are publicly available. They provide an objective performance assessment for future developments in the field of brain MRI reconstruction.
△ Less
Submitted 21 December, 2021; v1 submitted 9 November, 2020;
originally announced November 2020.
-
i-RIM applied to the fastMRI challenge
Authors:
Patrick Putzky,
Dimitrios Karkalousos,
Jonas Teuwen,
Nikita Miriakov,
Bart Bakker,
Matthan Caan,
Max Welling
Abstract:
We, team AImsterdam, summarize our submission to the fastMRI challenge (Zbontar et al., 2018). Our approach builds on recent advances in invertible learning to infer models as presented in Putzky and Welling (2019). Both, our single-coil and our multi-coil model share the same basic architecture.
We, team AImsterdam, summarize our submission to the fastMRI challenge (Zbontar et al., 2018). Our approach builds on recent advances in invertible learning to infer models as presented in Putzky and Welling (2019). Both, our single-coil and our multi-coil model share the same basic architecture.
△ Less
Submitted 20 October, 2019;
originally announced October 2019.
-
Predicting brain age with deep learning from raw imaging data results in a reliable and heritable biomarker
Authors:
James H Cole,
Rudra PK Poudel,
Dimosthenis Tsagkrasoulis,
Matthan WA Caan,
Claire Steves,
Tim D Spector,
Giovanni Montana
Abstract:
Machine learning analysis of neuroimaging data can accurately predict chronological age in healthy people and deviations from healthy brain ageing have been associated with cognitive impairment and disease. Here we sought to further establish the credentials of "brain-predicted age" as a biomarker of individual differences in the brain ageing process, using a predictive modelling approach based on…
▽ More
Machine learning analysis of neuroimaging data can accurately predict chronological age in healthy people and deviations from healthy brain ageing have been associated with cognitive impairment and disease. Here we sought to further establish the credentials of "brain-predicted age" as a biomarker of individual differences in the brain ageing process, using a predictive modelling approach based on deep learning, and specifically convolutional neural networks (CNN), and applied to both pre-processed and raw T1-weighted MRI data. Firstly, we aimed to demonstrate the accuracy of CNN brain-predicted age using a large dataset of healthy adults (N = 2001). Next, we sought to establish the heritability of brain-predicted age using a sample of monozygotic and dizygotic female twins (N = 62). Thirdly, we examined the test-retest and multi-centre reliability of brain-predicted age using two samples (within-scanner N = 20; between-scanner N = 11). CNN brain-predicted ages were generated and compared to a Gaussian Process Regression (GPR) approach, on all datasets. Input data were grey matter (GM) or white matter (WM) volumetric maps generated by Statistical Parametric Map** (SPM) or raw data. Brain-predicted age represents an accurate, highly reliable and genetically-valid phenotype, that has potential to be used as a biomarker of brain ageing. Moreover, age predictions can be accurately generated on raw T1-MRI data, substantially reducing computation time for novel data, bringing the process closer to giving real-time information on brain health in clinical settings.
△ Less
Submitted 8 December, 2016;
originally announced December 2016.