MyoPS: A Benchmark of Myocardial Pathology Segmentation Combining Three-Sequence Cardiac Magnetic Resonance Images
Authors:
Lei Li,
Fu** Wu,
Sihan Wang,
Xinzhe Luo,
Carlos Martin-Isla,
Shuwei Zhai,
Jianpeng Zhang,
Yanfei Liu7,
Zhen Zhang,
Markus J. Ankenbrand,
Haochuan Jiang,
Xiaoran Zhang,
Linhong Wang,
Tewodros Weldebirhan Arega,
Elif Altunok,
Zhou Zhao,
Feiyan Li,
Jun Ma,
** Yang,
Elodie Puybareau,
Ilkay Oksuz,
Stephanie Bricq,
Weisheng Li,
Kumaradevan Punithakumar,
Sotirios A. Tsaftaris
, et al. (7 additional authors not shown)
Abstract:
Assessment of myocardial viability is essential in diagnosis and treatment management of patients suffering from myocardial infarction, and classification of pathology on myocardium is the key to this assessment. This work defines a new task of medical image analysis, i.e., to perform myocardial pathology segmentation (MyoPS) combining three-sequence cardiac magnetic resonance (CMR) images, which…
▽ More
Assessment of myocardial viability is essential in diagnosis and treatment management of patients suffering from myocardial infarction, and classification of pathology on myocardium is the key to this assessment. This work defines a new task of medical image analysis, i.e., to perform myocardial pathology segmentation (MyoPS) combining three-sequence cardiac magnetic resonance (CMR) images, which was first proposed in the MyoPS challenge, in conjunction with MICCAI 2020. The challenge provided 45 paired and pre-aligned CMR images, allowing algorithms to combine the complementary information from the three CMR sequences for pathology segmentation. In this article, we provide details of the challenge, survey the works from fifteen participants and interpret their methods according to five aspects, i.e., preprocessing, data augmentation, learning strategy, model architecture and post-processing. In addition, we analyze the results with respect to different factors, in order to examine the key obstacles and explore potential of solutions, as well as to provide a benchmark for future research. We conclude that while promising results have been reported, the research is still in the early stage, and more in-depth exploration is needed before a successful application to the clinics. Note that MyoPS data and evaluation tool continue to be publicly available upon registration via its homepage (www.sdspeople.fudan.edu.cn/zhuangxiahai/0/myops20/).
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
MRI-PET Registration with Automated Algorithm in Pre-clinical Studies
Authors:
Nathanael L. Baisa,
Stéphanie Bricq,
Alain Lalande
Abstract:
Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) automatic 3-D registration is implemented and validated for small animal image volumes so that the high-resolution anatomical MRI information can be fused with the low spatial resolution of functional PET information for the localization of lesion that is currently in high demand in the study of tumor of cancer (oncology) and…
▽ More
Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) automatic 3-D registration is implemented and validated for small animal image volumes so that the high-resolution anatomical MRI information can be fused with the low spatial resolution of functional PET information for the localization of lesion that is currently in high demand in the study of tumor of cancer (oncology) and its corresponding preparation of pharmaceutical drugs. Though many registration algorithms are developed and applied on human brain volumes, these methods may not be as efficient on small animal datasets due to lack of intensity information and often the high anisotropy in voxel dimensions. Therefore, a fully automatic registration algorithm which can register not only assumably rigid small animal volumes such as brain but also deformable organs such as kidney, cardiac and chest is developed using a combination of global affine and local B-spline transformation models in which mutual information is used as a similarity criterion. The global affine registration uses a multi-resolution pyramid on image volumes of 3 levels whereas in local B-spline registration, a multi-resolution scheme is applied on the B-spline grid of 2 levels on the finest resolution of the image volumes in which only the transform itself is affected rather than the image volumes. Since mutual information lacks sufficient spatial information, PCA is used to inject it by estimating initial translation and rotation parameters. It is computationally efficient since it is implemented using C++ and ITK library, and is qualitatively and quantitatively shown that this PCA-initialized global registration followed by local registration is in close agreement with expert manual registration and outperforms the one without PCA initialization tested on small animal brain and kidney.
△ Less
Submitted 23 May, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.