-
Optimized Energy Efficient Virtualization and Content Caching in 5G Networks
Authors:
Ahmed N. Al-Quzweeni,
Ahmed Q. Lawey,
Taisir E. H. Elgorashi,
Jaafar M. H. Elmirghani
Abstract:
Network function virtualization (NFV) and content caching are two promising technologies that hold great potential for network operators and designers. This paper optimizes the deployment of NFV and content caching in 5G networks and focuses on the associated power consumption savings. In addition, it introduces an approach to combine content caching with NFV in one integrated architecture for ene…
▽ More
Network function virtualization (NFV) and content caching are two promising technologies that hold great potential for network operators and designers. This paper optimizes the deployment of NFV and content caching in 5G networks and focuses on the associated power consumption savings. In addition, it introduces an approach to combine content caching with NFV in one integrated architecture for energy aware 5G networks. A mixed integer linear programming (MILP) model has been developed to minimize the total power consumption by jointly optimizing the cache size, virtual machine (VM) workload, and the locations of both cache nodes and VMs. The results were investigated under the impact of core network virtual machines (CNVMs) inter-traffic. The result show that the optical line terminal (OLT) access network nodes are the optimum location for content caching and for hosting VMs during busy times of the day whilst IP over WDM core network nodes are the optimum locations for caching and VM placement during off-peak time. Furthermore, the results reveal that a virtualization-only approach is better than a caching-only approach for video streaming services where the virtualization-only approach compared to caching-only approach, achieves a maximum power saving of 7% (average 5%) when no CNVMs inter-traffic is considered and 6% (average 4%) with CNVMs inter-traffic at 10% of the total backhaul traffic. On the other hand, the integrated approach has a maximum power saving of 15% (average 9%) with and without CNVMs inter-traffic compared to the virtualization-only approach, and it achieves a maximum power saving of 21% (average 13%) without CNVMs inter-traffic and 20% (average 12%) when CNVMs inter-traffic is considered compared with the caching-only approach. In order to validate the MILP models and achieve real-time operation in our approaches, a heuristic was developed.
△ Less
Submitted 1 February, 2021;
originally announced February 2021.
-
Evaluation of Applications Latency in Server Centric Passive Optical Network Based Data Centre Architectures
Authors:
Azza E. A. Eltraify,
Mohamed O. I. Musa,
Ahmed Al-Quzweeni,
Jaafar M. H. Elmirghani
Abstract:
The number of applications running in the cloud has dramatically increased in the past decade as well as the number of users accessing them. Data centres resources, architectures and conditions define the performance of the applications running on them. One of the main measures of the network efficiency is the latency, which can have a huge effect on resources utilisation, power consumption and th…
▽ More
The number of applications running in the cloud has dramatically increased in the past decade as well as the number of users accessing them. Data centres resources, architectures and conditions define the performance of the applications running on them. One of the main measures of the network efficiency is the latency, which can have a huge effect on resources utilisation, power consumption and the overall performance. In this paper, the performance of a fog network is evaluated by measuring the latency while running a facial recognition software. The network consists of two processing cells, a core network and a PON cell. The results show how network latency is affected by running the facial recognition software in the end-to-end network setup introduced in this paper.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
Experimental Evaluation of Server Centric Passive Optical Network Based Data Centre Architecture
Authors:
Azza E. A. Eltraify,
Mohamed O. I. Musa,
Ahmed Al-Quzweeni,
Jaafar M. H. Elmirghani
Abstract:
Passive optical networks (PON) technology has recently been proposed as a solution for scalability, energy efficiency, high capacity, low cost, flexibility and oversubscription issues in data centres. This paper experimentally demonstrates and discusses the implementation of a server centric PON based data centre architecture with high speed and reliability. The architecture is set up using a set…
▽ More
Passive optical networks (PON) technology has recently been proposed as a solution for scalability, energy efficiency, high capacity, low cost, flexibility and oversubscription issues in data centres. This paper experimentally demonstrates and discusses the implementation of a server centric PON based data centre architecture with high speed and reliability. The architecture is set up using a set of servers grouped into racks directly connected together and to the Optical Line Terminal (OLT) through gateway servers. The switching and routing functionalities have been embedded into servers using 4x10GE Xilinx NetFPGA. Flow continuity has been observed through live video streaming using IP cameras transmitting over up to 110 km optical connections through WDM nodes and the PON network.
△ Less
Submitted 9 April, 2019;
originally announced April 2019.
-
Energy Efficient virtualization framework for 5G F-RAN
Authors:
Yu Zeng,
Ahmed Al-Quzweeni,
Taisir E. H. Elgorashi,
Jaafar M. H. Elmirghani
Abstract:
Fog radio access network (F-RAN) and virtualisation are promising technologies for 5G networks. In F-RAN, the fog and cloud computing are integrated where the conventional C-RAN functions are diverged to the edge devices of radio access networks. F-RAN is adopted to mitigate the burden of front-haul and improve the end to end (E2E) latency. On other hand, virtualization and network function virtua…
▽ More
Fog radio access network (F-RAN) and virtualisation are promising technologies for 5G networks. In F-RAN, the fog and cloud computing are integrated where the conventional C-RAN functions are diverged to the edge devices of radio access networks. F-RAN is adopted to mitigate the burden of front-haul and improve the end to end (E2E) latency. On other hand, virtualization and network function virtualization (NFV) are IT techniques that aim to convert the functions from hardware to software based functions. Many merits could be brought by the employment of NFV in mobile networks including a high degree of reliability, flexibility and energy efficiency. In this paper, a virtualization framework is introduced for F-RAN to improve the energy efficiency in 5G networks. In this framework, a gigabit passive optical network (GPON) is leveraged as a backbone network for the proposed F-RAN architecture where it connects several evolved nodes B (eNodeBs) via fibre cables. The energy-efficiency of the proposed F-RAN architecture has been investigated and compared with the conventional C-RAN architecture in two different scenarios using mixed integer linear programming (MILP) models. The MILP results indicate that on average a 30% power saving can be achieved by the F-RAN architecture compared with the C-RAN architecture.
△ Less
Submitted 4 April, 2019;
originally announced April 2019.
-
Optimized Energy Aware 5G Network Function Virtualization
Authors:
Ahmed N. Al-Quzweeni,
Ahmed Q. Lawey,
Taisir E. H. Elgorashi,
Jaafar M. H. Elmirghani
Abstract:
In this paper, network function virtualization (NFV) is identified as a promising key technology that can contribute to energy-efficiency improvement in 5G networks. an optical network supported architecture is proposed and investigated in this work to provide the wired infrastructure needed in 5G networks and to support NFV towards an energy efficient 5G networks. In this architecture the mobile…
▽ More
In this paper, network function virtualization (NFV) is identified as a promising key technology that can contribute to energy-efficiency improvement in 5G networks. an optical network supported architecture is proposed and investigated in this work to provide the wired infrastructure needed in 5G networks and to support NFV towards an energy efficient 5G networks. In this architecture the mobile core network functions as well as baseband function are virtualized and provided as VMs. the impact of the total number of active users in the network, backhaul/fronthaul configurations and VM inter-traffic are investigated. A mixed integer linear programming (MILP) optimising model is developed with the objective of minimising the total power consumption by optimizing the VMs location and VMs servers' utilisation. The MILP model results show that virtualization can result in up to 38% (average 34) energy saving. The results also reveal how the total number of active users affects the baseband VMs optimal distribution whilst the core network VMs distribution is affected mainly by the inter-traffic between the VMs. For real-time implementation, two heuristics are developed an Energy Efficient NFV without CNVMs inter-traffic (EENFVnoITr) heuristic and an Energy Efficient NFV with CNVMs inter-traffic (EENFVwithITr) heuristic, both produce comparable results to the optimal MILP results
△ Less
Submitted 21 December, 2018;
originally announced December 2018.
-
Experimental Evaluation of Passive Optical Network Based Data Centre Architecture
Authors:
AEA Eltraify,
M. Musa,
A. Al-Quzweeni,
J. Elmirghani
Abstract:
Passive optical networks (PON) technology is increasingly becoming an attractive solution in modern data centres as it provides energy efficient, high capacity, low cost, scalable and flexible connectivity. In this paper we report the implementation of a PON based data centre architecture that provides high resilience and high speed interconnections by providing alternative communication routes be…
▽ More
Passive optical networks (PON) technology is increasingly becoming an attractive solution in modern data centres as it provides energy efficient, high capacity, low cost, scalable and flexible connectivity. In this paper we report the implementation of a PON based data centre architecture that provides high resilience and high speed interconnections by providing alternative communication routes between servers in different racks. Each rack is divided into several groups of servers and connects to other racks and the Optical Line Terminal (OLT) through a set of server that acts as relay servers. We implement the switching and routing functionalities within servers using 4x10GE Xilinx NetFPGA, and demonstrate end-to-end communication using IP cameras live video streaming over up to 100 km optical connections through WDM nodes and the PON network.
△ Less
Submitted 18 August, 2018;
originally announced August 2018.