Skip to main content

Showing 1–7 of 7 results for author: Woods, E V

Searching in archive cond-mat. Search in all archives.
.
  1. arXiv:2402.04608  [pdf

    cond-mat.mtrl-sci cond-mat.soft

    Analysis of water ice in nanoporous copper needles using cryo atom probe tomography

    Authors: Levi Tegg, Ingrid E. McCarroll, Se-Ho Kim, Renelle Dubosq, Eric V. Woods, Ayman A. El-Zoka, Baptiste Gault, Julie M. Cairney

    Abstract: The application of atom probe tomography (APT) to frozen liquids is limited by difficulties in specimen preparation. Here, we report on the use of nanoporous Cu needles as a physical framework to hold water ice for investigation using APT. Nanoporous Cu needles are prepared by the electropolishing and dealloying of Cu-Mn matchstick precursors. Cryogenic scanning electron microscopy and focused-ion… ▽ More

    Submitted 7 February, 2024; originally announced February 2024.

  2. arXiv:2311.13224  [pdf

    cond-mat.mtrl-sci physics.app-ph

    Nanoporous gold thin films as substrates to analyze liquids by cryo-atom probe tomography

    Authors: E. V. Woods, A. Saksena, A. A. El-Zoka, L. T. Stephenson, T. M. Schwarz, M. P. Singh, L. S. Aota, S. -H. Kim, J. Schneider, B. Gault

    Abstract: Cryogenic atom probe tomography (cryo-APT) is being developed to enable nanoscale compositional analyses of frozen liquids. Yet, the availability of readily available substrates that allow for the fixation of liquids while providing sufficient strength to their interface, is still an issue. Here we propose the use of 1-2 microns thick binary alloy film of gold-silver (AuAg) sputtered onto flat sil… ▽ More

    Submitted 22 November, 2023; originally announced November 2023.

  3. arXiv:2309.07842  [pdf

    cond-mat.mtrl-sci

    Facilitating the systematic nanoscale study of battery materials by atom probe tomography through in-situ metal coating

    Authors: Mahander P Singh, Eric V Woods, Se Ho Kim, Chanwon Jung, Leonardo S. Aota, Baptiste Gault

    Abstract: Through its capability for 3D map** of Li at the nanoscale, atom probe tomography (APT) is poised to play a key role in understanding the microstructural degradation of lithium-ion batteries (LIB) during successive charge and discharge cycles. However, APT application to materials for LIB is plagued by the field induced delithiation (deintercalation) of Li-ions during the analysis itself that pr… ▽ More

    Submitted 14 September, 2023; originally announced September 2023.

  4. arXiv:2308.16672  [pdf

    physics.app-ph cond-mat.soft

    Scalable Substrate Development for Aqueous Biological Samples for Atom Probe Tomography

    Authors: Eric V. Woods, Se-Ho Kim, Ayman A. El-Zoka, Leigh T. Stephenson, Baptiste Gault

    Abstract: Reliable and consistent preparation of atom probe tomography (APT) specimens from aqueous and hydrated biological specimens remains a significant challenge. One particularly difficult process step is the use of a focused ion beam (FIB) instrument for preparing the required needle-shaped specimen, typically involving a "lift-out" procedure of a small sample of material. Here, two alternative substr… ▽ More

    Submitted 31 August, 2023; originally announced August 2023.

  5. arXiv:2303.18048  [pdf

    physics.app-ph cond-mat.mtrl-sci

    A versatile and reproducible cryo-sample preparation methodology for atom probe studies

    Authors: Eric V. Woods, Mahander P. Singh, Se-Ho Kim, Tim M. Schwarz, James O. Douglas, Ayman El-Zoka, Finn Giulani, Baptiste Gault

    Abstract: Repeatable and reliable site-specific preparation of specimens for atom probe tomography (APT) at cryogenic temperatures has proven challenging. A generalized workflow is required for cryogenic-specimen preparation including lift-out via focused-ion beam and in-situ deposition of cap** layers, to strengthen specimens that will be exposed to high electric field and stresses during field evaporati… ▽ More

    Submitted 31 March, 2023; originally announced March 2023.

  6. arXiv:2207.08154  [pdf

    cond-mat.mtrl-sci

    Understanding the degradation of a model Si-anode in Li-ion battery at the atomic-scale

    Authors: Se-Ho Kim, Kang Dong, Huan Zhao, Ayman A. El-Zoka, Xuyang Zhou, Eric V. Woods, Finn Giuliani, Ingo Manke, Dierk Raabe, Baptiste Gault

    Abstract: Si-anodes have long been candidates thanks to an expected ten-fold increase in capacity compared to graphite. However, details of the mechanisms governing their degradation remain elusive, hindering science-guided development of long-lived Si-based anodes. Here we demonstrate how the latest developments in cryo-atom probe tomography enable the in-depth analysis of the electrode and electrolyte, an… ▽ More

    Submitted 17 July, 2022; originally announced July 2022.

  7. arXiv:2102.01954  [pdf

    cond-mat.mtrl-sci

    Status and direction of atom probe analysis of frozen liquids

    Authors: Patrick Stender, Baptiste Gault, Tim M. Schwarz, Eric V. Woods, Se-Ho Kim, Jonas Ott, Leigh T. Stephenson, Guido Schmitz, Christoph Freysoldt, Johannes Kästner, Ayman A. El-Zoka

    Abstract: Imaging of liquids and cryogenic biological materials by electron microscopy has been recently enabled by innovative approaches for specimen preparation and the fast development of optimised instruments for cryo-enabled electron microscopy (cryo-EM). Yet, Cryo-EM typically lacks advanced analytical capabilities, in particular for light elements. With the development of protocols for frozen wet spe… ▽ More

    Submitted 3 February, 2021; originally announced February 2021.

    Comments: submitted for publication assocaited to the APT&M 2020 conference