Analysis of water ice in nanoporous copper needles using cryo atom probe tomography
Authors:
Levi Tegg,
Ingrid E. McCarroll,
Se-Ho Kim,
Renelle Dubosq,
Eric V. Woods,
Ayman A. El-Zoka,
Baptiste Gault,
Julie M. Cairney
Abstract:
The application of atom probe tomography (APT) to frozen liquids is limited by difficulties in specimen preparation. Here, we report on the use of nanoporous Cu needles as a physical framework to hold water ice for investigation using APT. Nanoporous Cu needles are prepared by the electropolishing and dealloying of Cu-Mn matchstick precursors. Cryogenic scanning electron microscopy and focused-ion…
▽ More
The application of atom probe tomography (APT) to frozen liquids is limited by difficulties in specimen preparation. Here, we report on the use of nanoporous Cu needles as a physical framework to hold water ice for investigation using APT. Nanoporous Cu needles are prepared by the electropolishing and dealloying of Cu-Mn matchstick precursors. Cryogenic scanning electron microscopy and focused-ion beam milling reveal a hierarchical, dendritic, highly-wettable microstructure. The atom probe mass spectrum is dominated by peaks of Cu+ and H(H2O)n+ up to n <= 3, and the reconstructed volume shows the protrusion of a Cu ligament into an ice-filled pore. The continuous Cu ligament network electrically connects the apex to the cryostage, leading to enhanced electric field at the apex and increased cooling, both of which simplify the mass spectrum compared to previous reports.
△ Less
Submitted 7 February, 2024;
originally announced February 2024.
-
Nanoporous gold thin films as substrates to analyze liquids by cryo-atom probe tomography
Authors:
E. V. Woods,
A. Saksena,
A. A. El-Zoka,
L. T. Stephenson,
T. M. Schwarz,
M. P. Singh,
L. S. Aota,
S. -H. Kim,
J. Schneider,
B. Gault
Abstract:
Cryogenic atom probe tomography (cryo-APT) is being developed to enable nanoscale compositional analyses of frozen liquids. Yet, the availability of readily available substrates that allow for the fixation of liquids while providing sufficient strength to their interface, is still an issue. Here we propose the use of 1-2 microns thick binary alloy film of gold-silver (AuAg) sputtered onto flat sil…
▽ More
Cryogenic atom probe tomography (cryo-APT) is being developed to enable nanoscale compositional analyses of frozen liquids. Yet, the availability of readily available substrates that allow for the fixation of liquids while providing sufficient strength to their interface, is still an issue. Here we propose the use of 1-2 microns thick binary alloy film of gold-silver (AuAg) sputtered onto flat silicon, with sufficient adhesion without an additional layer. Through chemical dealloying, we successfully fabricate a nanoporous substrate, with open-pore structure, which is mounted on a microarray of Si posts by lift out in the focused-ion beam, allowing for cryogenic fixation of liquids. We present cryo-APT results obtained after cryogenic sharpening, vacuum cryo-transfer and analysis of pure water on top and inside the nanoporous film. We demonstrate that this new substrate has the requisite characteristics for facilitating cryo-APT of frozen liquids, with a relatively lower volume of precious metals. This complete workflow represents an improved approach for frozen liquid analysis, from preparation of the films to the successful fixation of the liquid in the porous network, to cryo-atom probe tomography.
△ Less
Submitted 22 November, 2023;
originally announced November 2023.
-
Facilitating the systematic nanoscale study of battery materials by atom probe tomography through in-situ metal coating
Authors:
Mahander P Singh,
Eric V Woods,
Se Ho Kim,
Chanwon Jung,
Leonardo S. Aota,
Baptiste Gault
Abstract:
Through its capability for 3D map** of Li at the nanoscale, atom probe tomography (APT) is poised to play a key role in understanding the microstructural degradation of lithium-ion batteries (LIB) during successive charge and discharge cycles. However, APT application to materials for LIB is plagued by the field induced delithiation (deintercalation) of Li-ions during the analysis itself that pr…
▽ More
Through its capability for 3D map** of Li at the nanoscale, atom probe tomography (APT) is poised to play a key role in understanding the microstructural degradation of lithium-ion batteries (LIB) during successive charge and discharge cycles. However, APT application to materials for LIB is plagued by the field induced delithiation (deintercalation) of Li-ions during the analysis itself that prevents the precise assessment of the Li distribution. Here, we showcase how a thin Cr-coating, in-situ formed on APT specimens of NMC811 in the focused-ion beam (FIB), preserves the sample's integrity and circumvent this deleterious delithiation. Cr-coated specimens demonstrated remarkable improvements in data quality and virtually eliminated premature specimen failures, allowing for more precise measurements via. improved statistics. Through improved data analysis, we reveal substantial cation fluctuations in commercial grade NMC811, including complete grains of LiMnO. The current methodology stands out for its simplicity and cost-effectiveness and is a viable approach to prepare battery cathodes and anodes for systematic APT studies.
△ Less
Submitted 14 September, 2023;
originally announced September 2023.
-
Scalable Substrate Development for Aqueous Biological Samples for Atom Probe Tomography
Authors:
Eric V. Woods,
Se-Ho Kim,
Ayman A. El-Zoka,
Leigh T. Stephenson,
Baptiste Gault
Abstract:
Reliable and consistent preparation of atom probe tomography (APT) specimens from aqueous and hydrated biological specimens remains a significant challenge. One particularly difficult process step is the use of a focused ion beam (FIB) instrument for preparing the required needle-shaped specimen, typically involving a "lift-out" procedure of a small sample of material. Here, two alternative substr…
▽ More
Reliable and consistent preparation of atom probe tomography (APT) specimens from aqueous and hydrated biological specimens remains a significant challenge. One particularly difficult process step is the use of a focused ion beam (FIB) instrument for preparing the required needle-shaped specimen, typically involving a "lift-out" procedure of a small sample of material. Here, two alternative substrate designs are introduced that enable using FIB only for sharpening, along with example APT datasets. The first design is a laser-cut FIB-style half-grid close to those used for transmission-electron microscopy, that can be used in a grid holder compatible with APT pucks. The second design is a larger, standalone self-supporting substrate called a "crown", with several specimen positions that self-aligns in APT pucks, prepared by electrical discharge machining (EDM). Both designs are made nanoporous, to provide strength to the liquid-substrate interface, using chemical and vacuum dealloying. We select alpha brass a simple, widely available, lower-cost alternative to previously proposed substrates. We present the resulting designs, APT data, and provide suggestions to help drive wider community adoption.
△ Less
Submitted 31 August, 2023;
originally announced August 2023.
-
A versatile and reproducible cryo-sample preparation methodology for atom probe studies
Authors:
Eric V. Woods,
Mahander P. Singh,
Se-Ho Kim,
Tim M. Schwarz,
James O. Douglas,
Ayman El-Zoka,
Finn Giulani,
Baptiste Gault
Abstract:
Repeatable and reliable site-specific preparation of specimens for atom probe tomography (APT) at cryogenic temperatures has proven challenging. A generalized workflow is required for cryogenic-specimen preparation including lift-out via focused-ion beam and in-situ deposition of cap** layers, to strengthen specimens that will be exposed to high electric field and stresses during field evaporati…
▽ More
Repeatable and reliable site-specific preparation of specimens for atom probe tomography (APT) at cryogenic temperatures has proven challenging. A generalized workflow is required for cryogenic-specimen preparation including lift-out via focused-ion beam and in-situ deposition of cap** layers, to strengthen specimens that will be exposed to high electric field and stresses during field evaporation in APT, and protect them from environment during transfer into the atom probe. Here, we build on existing protocols, and showcase preparation and analysis of a variety of metals, oxides and supported frozen liquids and battery materials. We demonstrate reliable in-situ deposition of a metallic cap** layer that significantly improve the atom probe data quality for challenging material systems, particularly battery cathode materials which are subjected to delithiation during the atom probe analysis itself. Our workflow designed is versatile and transferable widely to other instruments.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
Understanding the degradation of a model Si-anode in Li-ion battery at the atomic-scale
Authors:
Se-Ho Kim,
Kang Dong,
Huan Zhao,
Ayman A. El-Zoka,
Xuyang Zhou,
Eric V. Woods,
Finn Giuliani,
Ingo Manke,
Dierk Raabe,
Baptiste Gault
Abstract:
Si-anodes have long been candidates thanks to an expected ten-fold increase in capacity compared to graphite. However, details of the mechanisms governing their degradation remain elusive, hindering science-guided development of long-lived Si-based anodes. Here we demonstrate how the latest developments in cryo-atom probe tomography enable the in-depth analysis of the electrode and electrolyte, an…
▽ More
Si-anodes have long been candidates thanks to an expected ten-fold increase in capacity compared to graphite. However, details of the mechanisms governing their degradation remain elusive, hindering science-guided development of long-lived Si-based anodes. Here we demonstrate how the latest developments in cryo-atom probe tomography enable the in-depth analysis of the electrode and electrolyte, and their interface at atomic-level.
△ Less
Submitted 17 July, 2022;
originally announced July 2022.
-
Status and direction of atom probe analysis of frozen liquids
Authors:
Patrick Stender,
Baptiste Gault,
Tim M. Schwarz,
Eric V. Woods,
Se-Ho Kim,
Jonas Ott,
Leigh T. Stephenson,
Guido Schmitz,
Christoph Freysoldt,
Johannes Kästner,
Ayman A. El-Zoka
Abstract:
Imaging of liquids and cryogenic biological materials by electron microscopy has been recently enabled by innovative approaches for specimen preparation and the fast development of optimised instruments for cryo-enabled electron microscopy (cryo-EM). Yet, Cryo-EM typically lacks advanced analytical capabilities, in particular for light elements. With the development of protocols for frozen wet spe…
▽ More
Imaging of liquids and cryogenic biological materials by electron microscopy has been recently enabled by innovative approaches for specimen preparation and the fast development of optimised instruments for cryo-enabled electron microscopy (cryo-EM). Yet, Cryo-EM typically lacks advanced analytical capabilities, in particular for light elements. With the development of protocols for frozen wet specimen preparation, atom probe tomography (APT) could advantageously complement insights gained by cryo-EM. Here, we report on different approaches that have been recently proposed to enable the analysis of relatively large volumes of frozen liquids from either a flat substrate or the fractured surface of a wire. Both allowed for analysing water ice layers which are several microns thick consisting of pure water, pure heavy-water and aqueous solutions. We discuss the merits of both approaches, and prospects for further developments in this area. Preliminary results raise numerous questions, in part concerning the physics underpinning field evaporation. We discuss these aspects and lay out some of the challenges regarding the APT analysis of frozen liquids.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.