-
Magnetic Force Microscopy: High Quality Factor Two-Pass Mode
Authors:
Christopher Habenschaden,
Sibylle Sievers,
Alexander Klasen,
Andrea Cerreta,
Hans Werner Schumacher
Abstract:
Magnetic force microscopy (MFM) is a well-established technique in scanning probe microscopy (SPM) that allows the imaging of magnetic samples with spatial resolution of tens of nm and stray fields down to the mT range. Spatial resolution and field sensitivity can be improved significantly by measuring in vacuum conditions. This effect originates from the higher quality factor (Q-factor) of the ca…
▽ More
Magnetic force microscopy (MFM) is a well-established technique in scanning probe microscopy (SPM) that allows the imaging of magnetic samples with spatial resolution of tens of nm and stray fields down to the mT range. Spatial resolution and field sensitivity can be improved significantly by measuring in vacuum conditions. This effect originates from the higher quality factor (Q-factor) of the cantilevers oscillation in vacuum compared to ambient conditions. However, while high Q-factors are desirable as they directly improve the magnetic measurement signal, they pose a challenge when pursuing a standard MFM two-pass (lift) mode measurement. At high Q-factors amplitude-based topography measurements become impossible and MFM phase response behaves non-linear. Here we present an implementation of a modified two-pass mode into a vacuum atomic force microscope (AFM) that overcomes these issues. By controlling Q in the first pass and using a phase-locked loop (PLL) technique in the second pass, high Q-factor measurements in vacuum are enabled. By measuring the cantilevers frequency shift instead of phase shift, otherwise emerging non-linearities are eliminated. The achievable improvements in resolution and sensitivity are demonstrated on patterned magnetic nanostructured samples. Elimination of non-linear response is showcased by a measurement of a very well-known calculable multilayer reference sample that is used for tip calibration in quantitative MFM (qMFM).
△ Less
Submitted 25 June, 2024;
originally announced June 2024.
-
Influence of the magneto-volume effect on the transient reflectivity of MnSi
Authors:
J. Kalin,
S. Sievers,
H. Füser,
A. Bauer,
C. Pfleiderer,
H. W. Schumacher,
M. Bieler
Abstract:
The magneto-volume effect is a well-established yet frequently overlooked phenomenon in magnetic materials that may affect a wide range of physical properties. Our study explores the influence of the magneto-volume effect on the transient reflectivity of MnSi, a well-known chiral magnet with strong magnetoelastic coupling. We observe a unipolar reflectivity transient in the paramagnetic phase, con…
▽ More
The magneto-volume effect is a well-established yet frequently overlooked phenomenon in magnetic materials that may affect a wide range of physical properties. Our study explores the influence of the magneto-volume effect on the transient reflectivity of MnSi, a well-known chiral magnet with strong magnetoelastic coupling. We observe a unipolar reflectivity transient in the paramagnetic phase, contrasting with a bipolar response in phases with magnetic long-range order. Comparing our findings with thermal expansion from literature, we establish that the bipolar response originates in the magneto-volume effect which dominates the thermal expansion and influences the optical reflectivity. Our results highlight not only that the magneto-volume effect must be considered when discussing transient reflectivity measurements of magnetic materials but also that such measurements permit to study the characteristic time scales of the magneto-volume effect itself, contributing to a deeper understanding of this often-neglected phenomenon.
△ Less
Submitted 13 May, 2024; v1 submitted 3 February, 2024;
originally announced February 2024.
-
arXiv:2401.04793
[pdf]
cond-mat.mtrl-sci
cond-mat.mes-hall
cond-mat.str-el
cond-mat.supr-con
quant-ph
2024 Roadmap on Magnetic Microscopy Techniques and Their Applications in Materials Science
Authors:
D. V. Christensen,
U. Staub,
T. R. Devidas,
B. Kalisky,
K. C. Nowack,
J. L. Webb,
U. L. Andersen,
A. Huck,
D. A. Broadway,
K. Wagner,
P. Maletinsky,
T. van der Sar,
C. R. Du,
A. Yacoby,
D. Collomb,
S. Bending,
A. Oral,
H. J. Hug,
A. -O. Mandru,
V. Neu,
H. W. Schumacher,
S. Sievers,
H. Saito,
A. A. Khajetoorians,
N. Hauptmann
, et al. (28 additional authors not shown)
Abstract:
Considering the growing interest in magnetic materials for unconventional computing, data storage, and sensor applications, there is active research not only on material synthesis but also characterisation of their properties. In addition to structural and integral magnetic characterisations, imaging of magnetization patterns, current distributions and magnetic fields at nano- and microscale is of…
▽ More
Considering the growing interest in magnetic materials for unconventional computing, data storage, and sensor applications, there is active research not only on material synthesis but also characterisation of their properties. In addition to structural and integral magnetic characterisations, imaging of magnetization patterns, current distributions and magnetic fields at nano- and microscale is of major importance to understand the material responses and qualify them for specific applications. In this roadmap, we aim to cover a broad portfolio of techniques to perform nano- and microscale magnetic imaging using SQUIDs, spin center and Hall effect magnetometries, scanning probe microscopies, x-ray- and electron-based methods as well as magnetooptics and nanoMRI. The roadmap is aimed as a single access point of information for experts in the field as well as the young generation of students outlining prospects of the development of magnetic imaging technologies for the upcoming decade with a focus on physics, materials science, and chemistry of planar, 3D and geometrically curved objects of different material classes including 2D materials, complex oxides, semi-metals, multiferroics, skyrmions, antiferromagnets, frustrated magnets, magnetic molecules/nanoparticles, ionic conductors, superconductors, spintronic and spinorbitronic materials.
△ Less
Submitted 9 January, 2024;
originally announced January 2024.
-
Suppression of the spin waves nonreciprocity due to interfacial Dzyaloshinskii Moriya interaction by lateral confinement in magnetic nanostructures
Authors:
S. Tacchi,
R. Silvani,
M. Kuepferling,
A. Fernandez Scarioni,
S. Sievers,
H. W. Schumacher,
E. Darwin,
M. -A. Syskaki,
G. Jakob,
M. Klaui,
G. Carlotti
Abstract:
Despite the huge recent interest towards chiral magnetism related to the interfacial Dzyaloshinskii Moriya interaction (iDMI) in layered systems, there is a lack of experimental data on the effect of iDMI on the spin waves eigenmodes of laterally confined nanostructures. Here we exploit Brillouin Light Scattering (BLS) to analyze the spin wave eigenmodes of non-interacting circular and elliptical…
▽ More
Despite the huge recent interest towards chiral magnetism related to the interfacial Dzyaloshinskii Moriya interaction (iDMI) in layered systems, there is a lack of experimental data on the effect of iDMI on the spin waves eigenmodes of laterally confined nanostructures. Here we exploit Brillouin Light Scattering (BLS) to analyze the spin wave eigenmodes of non-interacting circular and elliptical dots, as well as of long stripes, patterned starting from a Pt(3.4 nm)/CoFeB(0.8 nm) bilayer, with lateral dimensions ranging from 100 nm to 400 nm. Our experimental results, corroborated by micromagnetic simulations based on the GPU-accelerated MuMax3 software package, provide evidence for a strong suppression of the frequency asymmetry between counter-propagating spin waves (corresponding to either Stokes or anti-Stokes peaks in BLS spectra), when the lateral confinement is reduced from 400 nm to 100 nm, i.e. when it becomes lower than the light wavelength. Such an evolution reflects the modification of the spin wave character from propagating to stationary and indicates that the BLS based method of quantifying the i-DMI strength from the frequency difference of counter propagating spin waves is not applicable in the case of magnetic elements with lateral dimension below about 400 nm.
△ Less
Submitted 28 June, 2023;
originally announced June 2023.
-
Optical creation and annihilation of skyrmion patches in a bulk chiral magnet
Authors:
Jantje Kalin,
Sibylle Sievers,
Daniel Kalin,
Andreas Bauer,
Robin Abram,
Heiko Füser,
Hans Werner Schumacher,
Christian Pfleiderer,
Mark Bieler
Abstract:
A key challenge for the realization of future skyrmion devices comprises the controlled creation, annihilation and detection of these topologically non-trivial magnetic spin textures. In this study, we report an all-optical approach for writing, deleting, and reading skyrmions in the cubic chiral magnet Fe$_{0.25}$Co$_{0.75}$Si based on thermal quenching. Using focused femtosecond laser pulses, pa…
▽ More
A key challenge for the realization of future skyrmion devices comprises the controlled creation, annihilation and detection of these topologically non-trivial magnetic spin textures. In this study, we report an all-optical approach for writing, deleting, and reading skyrmions in the cubic chiral magnet Fe$_{0.25}$Co$_{0.75}$Si based on thermal quenching. Using focused femtosecond laser pulses, patches of a skyrmion state are created and annihilated locally, demonstrating unprecedented control of thermally metastable skyrmions in a bulk compound. The skyrmion state is read-out by analyzing the microwave spin excitations in time-resolved magneto-optical Kerr effect measurements. Extracting the magnetic field and laser fluence dependence, we find well-separated magnetic field regimes and different laser fluence thresholds for the laser-induced creation and annihilation of metastable skyrmions. The all-optical skyrmion control, as established in this study for a model system, represents a promising and energy-efficient approach for the realization of skyrmions as magnetic bits in future storage devices, reminiscent of magneto-optical storage devices in the past.
△ Less
Submitted 31 May, 2023;
originally announced June 2023.
-
Optically excited spin dynamics of thermally metastable skyrmions in Fe$_{0.75}$Co$_{0.25}$Si
Authors:
Jantje Kalin,
Sibylle Sievers,
Heiko Füser,
Hans Werner Schumacher,
Felipe García-Sánchez,
Andreas Bauer,
Christian Pfleiderer,
Mark Bieler
Abstract:
We investigate the microwave spin excitations of the cubic chiral magnet Fe$_{0.75}$Co$_{0.25}$Si as driven by the thermal modulation of magnetic interactions via laser heating and probed by time-resolved measurements of the magneto-optical Kerr effect. Focusing on the topologically nontrivial skyrmion lattice state, the dynamic properties in thermodynamic equilibrium are compared with those of a…
▽ More
We investigate the microwave spin excitations of the cubic chiral magnet Fe$_{0.75}$Co$_{0.25}$Si as driven by the thermal modulation of magnetic interactions via laser heating and probed by time-resolved measurements of the magneto-optical Kerr effect. Focusing on the topologically nontrivial skyrmion lattice state, the dynamic properties in thermodynamic equilibrium are compared with those of a metastable state prepared by means of rapid field cooling. In both cases, we find precessional and exponential contributions to the dynamic response, characteristic of a breathing mode and energy dissipation, respectively. When taking into account the universal scaling as a function of temperature, the precession frequencies in the equilibrium and metastable skyrmion state are in excellent quantitative agreement. This finding highlights that skyrmion states far from thermal equilibrium promise great flexibility, for instance with respect to temperature and field scales, both for possible microwave applications and the study of fundamental properties.
△ Less
Submitted 29 June, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
A Ti/Pt/Co multilayer stack for transfer function based magnetic force microscopy calibrations
Authors:
Baha Sakar,
Sibylle Sievers,
Alexander Fernandez Scarioni,
Felipe Garcia-Sanchez,
Ilker Oztoprak,
Hans Werner Schumacher,
Osman Ozturk
Abstract:
Magnetic force microscopy is a widespread technique for imaging magnetic structures with a resolution of some 10 nanometers. MFM can be calibrated to obtain quantitative spatially resolved magnetization data in units of A/m by determining the calibrated point spread function of the instrument, its instrument calibration function (ICF), from a measurement of a well-known reference sample. Beyond qu…
▽ More
Magnetic force microscopy is a widespread technique for imaging magnetic structures with a resolution of some 10 nanometers. MFM can be calibrated to obtain quantitative spatially resolved magnetization data in units of A/m by determining the calibrated point spread function of the instrument, its instrument calibration function (ICF), from a measurement of a well-known reference sample. Beyond quantifying the MFM data, a deconvolution of the MFM image data with the ICF also corrects the smearing caused by the finite width of the MFM tip stray field distribution. However, the quality of the calibration depends critically on the calculability of the magnetization distribution of the reference sample. Here, we discuss a Ti/Pt/Co multilayer stack that shows a stripe domain pattern as a suitable reference material. A precise control of the fabrication process, combined with a characterization of the sample micromagnetic parameters, allows reliable calculation of the sample's magnetic stray field, proven by a very good agreement between micromagnetic simulations and qMFM measurements. A calibrated qMFM measurement using the Ti/Pt/Co stack as a reference sample is shown and validated, and the application area for quantitative MFM measurements calibrated with the Ti/Pt/Co stack is discussed
△ Less
Submitted 24 January, 2022;
originally announced January 2022.
-
Quantum calibrated magnetic force microscopy
Authors:
Baha Sakar,
Yan Liu,
Sibylle Sievers,
Volker Neu,
Johannes Lang,
Christian Osterkamp,
Matthew L. Markham,
Osman Öztürk,
Fedor Jelezko,
Hans W. Schumacher
Abstract:
We report the quantum calibration of a magnetic force microscope (MFM) by measuring the two-dimensional magnetic stray field distribution of the MFM tip using a single nitrogen vacancy (NV) center in diamond. From the measured stray field distribution and the mechanical properties of the cantilever a calibration function is derived allowing to convert MFM images to quantum calibrated stray field m…
▽ More
We report the quantum calibration of a magnetic force microscope (MFM) by measuring the two-dimensional magnetic stray field distribution of the MFM tip using a single nitrogen vacancy (NV) center in diamond. From the measured stray field distribution and the mechanical properties of the cantilever a calibration function is derived allowing to convert MFM images to quantum calibrated stray field maps. This novel approach overcomes limitations of prior MFM calibration schemes and allows quantum calibrated nanoscale stray field measurements in a field range inaccessible to scanning NV magnetometry. Quantum calibrated measurements of a stray field reference sample allow its use as a transfer standard, opening the road towards fast and easily accessible quantum traceable calibrations of virtually any MFM.
△ Less
Submitted 6 December, 2021; v1 submitted 25 March, 2021;
originally announced March 2021.
-
Thermoelectric signature of individual skyrmions
Authors:
Alexander Fernández Scarioni,
Craig Barton,
Héctor Corte-León,
Sibylle Sievers,
Xiukun Hu,
Fernando Ajejas,
William Legrand,
Nicolas Reyren,
Vincent Cros,
Olga Kazakova,
Hans W. Schumacher
Abstract:
We experimentally study the thermoelectrical signature of individual skyrmions in chiral Pt/Co/Ru multilayers. Using a combination of controlled nucleation, single skyrmion annihilation, and magnetic field dependent measurements the thermoelectric signature of individual skyrmions is characterized. The observed signature is explained by the anomalous Nernst effect of the skyrmions spin structure.…
▽ More
We experimentally study the thermoelectrical signature of individual skyrmions in chiral Pt/Co/Ru multilayers. Using a combination of controlled nucleation, single skyrmion annihilation, and magnetic field dependent measurements the thermoelectric signature of individual skyrmions is characterized. The observed signature is explained by the anomalous Nernst effect of the skyrmions spin structure. Possible topological contributions to the observed thermoelectrical signature are discussed. Such thermoelectrical characterization allows for non-invasive detection and counting of skyrmions and enables fundamental studies of topological thermoelectric effects on the nano scale
△ Less
Submitted 17 April, 2020; v1 submitted 28 January, 2020;
originally announced January 2020.
-
Uncertainty Analysis of Stray Field Measurements by Quantitative Magnetic Force Microscopy
Authors:
Xiukun Hu,
Gaoliang Dai,
Sibylle Sievers,
Alexander Fernández Scarioni,
Volker Neu,
Mark Bieler,
Hans Werner Schumacher
Abstract:
Magnetic force microscopy (MFM) measurements generally provide phase images which represent the signature of domain structures on the surface of nanomaterials. To quantitatively determine magnetic stray fields based on an MFM image requires calibrated properties of the magnetic tip. In this work, an approach is presented for calibrating a magnetic tip using a Co/Pt multilayered film as a reference…
▽ More
Magnetic force microscopy (MFM) measurements generally provide phase images which represent the signature of domain structures on the surface of nanomaterials. To quantitatively determine magnetic stray fields based on an MFM image requires calibrated properties of the magnetic tip. In this work, an approach is presented for calibrating a magnetic tip using a Co/Pt multilayered film as a reference sample which shows stable well-known magnetic properties and well-defined perpendicular band domains. The approach is based on a regularized deconvolution process in Fourier domain with a Wiener filter and the L-curve method for determining a suitable regularization parameter to get a physically reasonable result. The calibrated tip is applied for a traceable quantitative determination of the stray fields of a test sample which has a patial frequency spectrum covered by that of the reference sample. According to the "Guide to the expression of uncertainty in measurement", uncertainties of the processing algorithm are estimated considering the fact that the regularization influences significantly the quantitative analysis. We discuss relevant uncertainty components and their propagations between real domain and Fourier domain for both, the tip calibration procedure and the stray field calculation, and propose an uncertainty evaluation procedure for quantitative magnetic force microscopy.
△ Less
Submitted 19 February, 2020; v1 submitted 18 December, 2019;
originally announced December 2019.
-
Excitation and coherent control of magnetization dynamics in magnetic tunnel junctions using acoustic pulses
Authors:
H. F. Yang,
F. Garcia-Sanchez,
X. K. Hu,
S. Sievers,
T. Böhnert,
J. D. Costa,
M. Tarequzzaman,
R. Ferreira,
M. Bieler,
H. W. Schumacher
Abstract:
We experimentally study magnetization dynamics in magnetic tunnel junctions driven by femtosecond-laser-induced surface acoustic waves. The acoustic pulses induce a magnetization precession in the free layer of the magnetic tunnel junction through magnetoelastic coupling. The frequency and amplitude of the precession shows a pronounced dependence on the applied magnetic field and the laser excitat…
▽ More
We experimentally study magnetization dynamics in magnetic tunnel junctions driven by femtosecond-laser-induced surface acoustic waves. The acoustic pulses induce a magnetization precession in the free layer of the magnetic tunnel junction through magnetoelastic coupling. The frequency and amplitude of the precession shows a pronounced dependence on the applied magnetic field and the laser excitation position. Comparing the acoustic-wave-induced precession frequencies with precession induced by charge currents and with micromagnetic simulations we identify spatially non-uniform magnetization modes localized close the edge regions as being responsible for the optically induced magnetization dynamics. The experimental scheme even allows us to coherently control the magnetization precession using two acoustic pulses. This might prove important for future applications requiring ultrafast spin manipulation. Additionally, our results directly pinpoint the importance of acoustic pulses since they could be relevant when investigating optically-induced temperature effects in magnetic structures.
△ Less
Submitted 27 April, 2018;
originally announced April 2018.
-
Investigation of a possible electronic phase separation in the magnetic semiconductors Ga$_{1-x}$Mn$_{x}$As and Ga$_{1-x}$Mn$_{x}$P by means of fluctuation spectroscopy
Authors:
Martin Lonsky,
Jan Teschabai-Oglu,
Klaus Pierz,
Sibylle Sievers,
Hans Werner Schumacher,
Ye Yuan,
Roman Böttger,
Shengqiang Zhou,
Jens Müller
Abstract:
We present systematic temperature-dependent resistance noise measurements on a series of ferromagnetic Ga$_{1-x}$Mn$_{x}$As epitaxial thin films covering a large parameter space in terms of the Mn content $x$ and other variations regarding sample fabrication. We infer that the electronic noise is dominated by switching processes related to impurities in the entire temperature range. While metallic…
▽ More
We present systematic temperature-dependent resistance noise measurements on a series of ferromagnetic Ga$_{1-x}$Mn$_{x}$As epitaxial thin films covering a large parameter space in terms of the Mn content $x$ and other variations regarding sample fabrication. We infer that the electronic noise is dominated by switching processes related to impurities in the entire temperature range. While metallic compounds with $x>2$ % do not exhibit any significant change in the low-frequency resistance noise around the Curie temperature $T_\mathrm{C}$, we find indications for an electronic phase separation in films with $x<2$ % in the vicinity of $T_\mathrm{C}$, manifesting itself in a maximum in the noise power spectral density. These results are compared with noise measurements on an insulating Ga$_{1-x}$Mn$_{x}$P reference sample, for which the evidence for an electronic phase separation is even stronger and a possible percolation of bound magnetic polarons is discussed. Another aspect addressed in this work is the effect of ion-irradiation induced disorder on the electronic properties of Ga$_{1-x}$Mn$_{x}$As films and, in particular, whether any electronic inhomogeneities can be observed in this case. Finally, we put our findings into the context of the ongoing debate on the electronic structure and the development of spontaneous magnetization in these materials.
△ Less
Submitted 17 November, 2017; v1 submitted 8 May, 2017;
originally announced May 2017.
-
Domain wall magneto-Seebeck effect
Authors:
Patryk Krzysteczko,
Xiukun Hu,
Niklas Liebing,
Sibylle Sievers,
Hans W. Schumacher
Abstract:
The interplay between charge, spin, and heat currents in magnetic nano systems subjected to a temperature gradient has lead to a variety of novel effects and promising applications studied in the fast-growing field of spincaloritronics. Here we explore the magnetothermoelectrical properties of an individual magnetic domain wall in a permalloy nanowire. In thermal gradients of the order of few Kelv…
▽ More
The interplay between charge, spin, and heat currents in magnetic nano systems subjected to a temperature gradient has lead to a variety of novel effects and promising applications studied in the fast-growing field of spincaloritronics. Here we explore the magnetothermoelectrical properties of an individual magnetic domain wall in a permalloy nanowire. In thermal gradients of the order of few Kelvin per micrometer along the long wire axis, we find a clear magneto-Seebeck signature due to the presence of a single domain wall. The observed domain wall magneto-Seebeck effect can be explained by the magnetization-dependent Seebeck coefficient of permalloy in combination with the local spin configuration of the domain wall.
△ Less
Submitted 29 December, 2014;
originally announced December 2014.
-
Towards wafer scale inductive characterization of spin transfer torque critical current density of magnetic tunnel junction stacks
Authors:
Sibylle Sievers,
Niklas Liebing,
Santiago Serrano-Guisan,
Ricardo Ferreira,
Elvira Paz,
Ambra Caprile,
Alessandra Manzin,
Massimo Pasquale,
Witold Skowroński,
Tomasz Stobiecki,
Karsten Rott,
Günter Reiss,
Jürgen Langer,
Berthold Ocker,
Hans Werner Schumacher
Abstract:
We explore the prospects of wafer scale inductive probing of the critical current density $j^{c0}$ for spin transfer torque switching of a CoFeB/MgO/CoFeB magnetic tunnel junction with varying MgO thickness. From inductive measurements magnetostatic parameters and the effective dam** are derived and $j^{c0}$ is calculated based on spin transfer torque equations. The inductive values compare well…
▽ More
We explore the prospects of wafer scale inductive probing of the critical current density $j^{c0}$ for spin transfer torque switching of a CoFeB/MgO/CoFeB magnetic tunnel junction with varying MgO thickness. From inductive measurements magnetostatic parameters and the effective dam** are derived and $j^{c0}$ is calculated based on spin transfer torque equations. The inductive values compare well to the values derived from current induced switching measurements on individual nanopillars. Using a wafer scale inductive probe head could in the future enable wafer probe station based metrology of $j^{c0}$.
△ Less
Submitted 18 November, 2014;
originally announced November 2014.
-
Towards wafer scale inductive determination of magnetostatic and dynamic parameters of magnetic thin films and multilayers
Authors:
Sibylle Sievers,
Niklas Liebing,
Paul Nass,
Santiago Serrano-Guisan,
Massimo Pasquale,
Hans Werner Schumacher
Abstract:
We investigate an inductive probe head suitable for non-invasive characterization of the magnetostatic and dynamic parameters of magnetic thin films and multilayers on the wafer scale. The probe is based on a planar waveguide with rearward high frequency connectors that can be brought in close contact to the wafer surface. Inductive characterization of the magnetic material is carried out by vecto…
▽ More
We investigate an inductive probe head suitable for non-invasive characterization of the magnetostatic and dynamic parameters of magnetic thin films and multilayers on the wafer scale. The probe is based on a planar waveguide with rearward high frequency connectors that can be brought in close contact to the wafer surface. Inductive characterization of the magnetic material is carried out by vector network analyzer ferromagnetic resonance. Analysis of the field dispersion of the resonance allows the determination of key material parameters such as the saturation magnetization MS or the effective dam** parameter Meff. Three waveguide designs are tested. The broadband frequency response is characterized and the suitability for inductive determination of MS and Meff is compared. Integration of such probes in a wafer prober could in the future allow wafer scale in-line testing of magnetostatic and dynamic key material parameters of magnetic thin films and multilayers.
△ Less
Submitted 24 October, 2013;
originally announced October 2013.
-
Broadband ferromagnetic resonance characterization of GaMnAs thin films
Authors:
Aymen Ben Hamida,
Sibylle Sievers,
Klaus Pierz,
Hans Werner Schumacher
Abstract:
The precessional magnetization dynamics of GaMnAs thin films are characterized by broadband network analyzer ferromagnetic resonance (FMR) in a coplanar geometry at cryogenic temperatures. The FMR frequencies are characterized as function of in-plane field angle and field amplitude. Using an extended Kittel model of the FMR dispersion the magnetic film parameters such as saturation magnetization a…
▽ More
The precessional magnetization dynamics of GaMnAs thin films are characterized by broadband network analyzer ferromagnetic resonance (FMR) in a coplanar geometry at cryogenic temperatures. The FMR frequencies are characterized as function of in-plane field angle and field amplitude. Using an extended Kittel model of the FMR dispersion the magnetic film parameters such as saturation magnetization and anisotropies are derived. The modification of the FMR behavior and of the magnetic parameters of the thin film upon annealing is analyzed.
△ Less
Submitted 6 August, 2013;
originally announced August 2013.
-
The influence of individual lattice defects on the domain structure in magnetic antidot lattices
Authors:
X. K. Hu,
S. Sievers,
A. Müller,
H. W. Schumacher
Abstract:
We numerically and experimentally investigate the influence of single defects consisting of a missing antidot on the spin configurations in rectangular permalloy antidot lattices. The introduction of such lattice defects leads to the nucleation of complex domain structures after the decay of a saturating magnetic field. Micromagnetic simulations yield four typical domain configurations around the…
▽ More
We numerically and experimentally investigate the influence of single defects consisting of a missing antidot on the spin configurations in rectangular permalloy antidot lattices. The introduction of such lattice defects leads to the nucleation of complex domain structures after the decay of a saturating magnetic field. Micromagnetic simulations yield four typical domain configurations around the defect having distinct energy densities. The existence of the four spin configurations is confirmed by magnetic force microscopy on antidot lattices containing individual defects.
△ Less
Submitted 14 March, 2013; v1 submitted 5 April, 2012;
originally announced April 2012.
-
Classification of super domains and super domain walls in permalloy antidot lattices
Authors:
X. K. Hu,
S. Sievers,
A. Müller,
V. Janke,
H. W. Schumacher
Abstract:
We study the remanent domain configurations of rectangular permalloy antidot lattices over a range of lattice parameters. The influence of antidot diameter, antidot spacing, and the aspect ratio of the lattice on the remanent domain configuration are investigated by magnetic force microscopy and supported by micromagnetic simulations. In the remanent state, areas of cells with the same orientation…
▽ More
We study the remanent domain configurations of rectangular permalloy antidot lattices over a range of lattice parameters. The influence of antidot diameter, antidot spacing, and the aspect ratio of the lattice on the remanent domain configuration are investigated by magnetic force microscopy and supported by micromagnetic simulations. In the remanent state, areas of cells with the same orientation of average magnetization form magnetic super domains separated by super domain walls (SDWs). Two types of SDWs are identified. The first type is characterized by low stray field energy, is linear, and expands over many lattice constants. In contrast the second type shows high stray field energy and is situated at kinks of low energy SDWs. Its width can vary from a minimum of two lattice cells up to several lattice constants, depending on the lattice parameters. The occurrence and structure of these two types of SDWs as function of lattice parameters are classified and discussed in terms of the interplay of stray field and exchange energy.
△ Less
Submitted 22 July, 2011; v1 submitted 2 March, 2011;
originally announced March 2011.
-
Quantitative measurement of the magnetic moment of an individual magnetic nanoparticle by magnetic force microscopy
Authors:
Kai-Felix Braun,
Sibylle Sievers,
Dietmar Eberbeck,
Stefan Gustafsson,
Eva Olsson,
Hans Werner Schumacher,
Uwe Siegner
Abstract:
We demonstrate the quantitative measurement of the magnetization of individual magnetic nanoparticles (MNP) using a magnetic force microscope (MFM). The quantitative measurement is realized by calibration of the MFM signal using an MNP reference sample with traceably determined magnetization. A resolution of the magnetic moment of the order of 10^(-18) Am^2 under ambient conditions is demonstrat…
▽ More
We demonstrate the quantitative measurement of the magnetization of individual magnetic nanoparticles (MNP) using a magnetic force microscope (MFM). The quantitative measurement is realized by calibration of the MFM signal using an MNP reference sample with traceably determined magnetization. A resolution of the magnetic moment of the order of 10^(-18) Am^2 under ambient conditions is demonstrated which is presently limited by the tip's magnetic moment and the noise level of the instrument. The calibration scheme can be applied to practically any MFM and tip thus allowing a wide range of future applications e.g. in nanomagnetism and biotechnology.
△ Less
Submitted 19 February, 2010;
originally announced February 2010.