-
Ferrimagnetic Heusler tunnel junctions with fast spin-transfer torque switching enabled by low magnetization
Authors:
Chirag Garg,
Panagiotis Ch. Filippou,
Ikhtiar,
Yari Ferrante,
See-Hun Yang,
Brian Hughes,
Charles T. Rettner,
Timothy Phung,
Sergey Faleev,
Teya Topuria,
Mahesh G. Samant,
Jaewoo Jeong,
Stuart S. P. Parkin
Abstract:
Magnetic random access memory that uses magnetic tunnel junction memory cells is a high performance, non-volatile memory technology that goes beyond traditional charge-based memories. Today its speed is limited by the high magnetization of the memory storage layer. Here we show that fast and highly reliable switching is possible using a very low magnetization ferrimagnetic Heusler alloy, Mn3Ge. Mo…
▽ More
Magnetic random access memory that uses magnetic tunnel junction memory cells is a high performance, non-volatile memory technology that goes beyond traditional charge-based memories. Today its speed is limited by the high magnetization of the memory storage layer. Here we show that fast and highly reliable switching is possible using a very low magnetization ferrimagnetic Heusler alloy, Mn3Ge. Moreover, the tunneling magnetoresistance is the highest yet achieved for a ferrimagnetic material at ambient temperature. Furthermore, the devices were prepared on technologically relevant amorphous substrates using a novel combination of a nitride seed layer and a chemical templating layer. These results show a clear path to the lowering of switching currents using ferrimagnetic Heusler materials and, therefore, to the scaling of high performance magnetic random access memories beyond those nodes possible with ferromagnetic devices.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
Merged-Element Transmons: Design and Qubit Performance
Authors:
H. J. Mamin,
E. Huang,
S. Carnevale,
C. T. Rettner,
N. Arellano,
M. H. Sherwood,
C. Kurter,
B. Trimm,
M. Sandberg,
R. M. Shelby,
M. A. Mueed,
B. A. Madon,
A. Pushp,
M. Steffen,
D. Rugar
Abstract:
We have demonstrated a novel type of superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon (MET) potentially offers a smaller footprint and simpler fabrication than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces relative electric field part…
▽ More
We have demonstrated a novel type of superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon (MET) potentially offers a smaller footprint and simpler fabrication than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces relative electric field participation from other interfaces. By combining micrometer-scale Al/AlOx/Al junctions with long oxidations and novel processing, we have produced functional devices with $E_{J}$/$E_{C}$ in the low transmon regime ($E_{J}$/$E_{C}$ $\lesssim$30). Cryogenic I-V measurements show sharp dI/dV structure with low sub-gap conduction. Qubit spectroscopy of tunable versions show a small number of avoided level crossings, suggesting the presence of two-level systems (TLS). We have observed mean T1 times typically in the range of 10-90 microseconds, with some annealed devices exhibiting T1 > 100 microseconds over several hours. The results suggest that energy relaxation in conventional, small-junction transmons is not limited by junction loss.
△ Less
Submitted 13 August, 2021; v1 submitted 16 March, 2021;
originally announced March 2021.
-
Proton magnetic resonance imaging with a nitrogen-vacancy spin sensor
Authors:
D. Rugar,
H. J. Mamin,
M. H. Sherwood,
M. Kim,
C. T. Rettner,
K. Ohno,
D. D. Awschalom
Abstract:
Nuclear magnetic resonance (NMR) imaging with nanometer resolution requires new detection techniques with sensitivity well beyond the capability of conventional inductive detection. Here, we demonstrate two dimensional imaging of $^1$H NMR from an organic test sample using a single nitrogen-vacancy center in diamond as the sensor. The NV center detects the oscillating magnetic field from precessin…
▽ More
Nuclear magnetic resonance (NMR) imaging with nanometer resolution requires new detection techniques with sensitivity well beyond the capability of conventional inductive detection. Here, we demonstrate two dimensional imaging of $^1$H NMR from an organic test sample using a single nitrogen-vacancy center in diamond as the sensor. The NV center detects the oscillating magnetic field from precessing protons in the sample as the sample is scanned past the NV center. A spatial resolution of 12 nm is shown, limited primarily by the scan accuracy. With further development, NV-detected magnetic resonance imaging could lead to a new tool for three-dimensional imaging of complex nanostructures, including biomolecules.
△ Less
Submitted 11 June, 2014;
originally announced June 2014.
-
Multipulse Double-Quantum Magnetometry With Near-Surface Nitrogen Vacancy Centers
Authors:
H. J. Mamin,
M. H. Sherwood,
M. Kim,
C. T. Rettner,
K. Ohno,
D. D. Awschalom,
D. Rugar
Abstract:
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the S=1 nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme works in arbitrary magnetic bias fields and is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual…
▽ More
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the S=1 nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme works in arbitrary magnetic bias fields and is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual frequency microwave excitation and show its effectiveness for double-quantum state swaps. Using multipulse sequences of up to 128 pulses under optimized conditions, we show enhancement of the SNR by up to a factor of 2 in detecting NMR statistical signals, with a 4 times enhancement theoretically possible.
△ Less
Submitted 15 July, 2015; v1 submitted 29 April, 2014;
originally announced April 2014.
-
Nuclear magnetic resonance force microscopy with a microwire rf source
Authors:
M. Poggio,
C. L. Degen,
C. T. Rettner,
H. J. Mamin,
D. Rugar
Abstract:
We use a 1.0-um-wide patterned Cu wire with an integrated nanomagnetic tip to measure the statistical nuclear polarization of 19F in CaF2 by magnetic resonance force microscopy (MRFM). With less than 350 uW of dissipated power, we achieve rf magnetic fields over 4 mT at 115 MHz for a sample positioned within 100 nm of the "microwire" rf source. A 200-nm diameter FeCo tip integrated onto the wire…
▽ More
We use a 1.0-um-wide patterned Cu wire with an integrated nanomagnetic tip to measure the statistical nuclear polarization of 19F in CaF2 by magnetic resonance force microscopy (MRFM). With less than 350 uW of dissipated power, we achieve rf magnetic fields over 4 mT at 115 MHz for a sample positioned within 100 nm of the "microwire" rf source. A 200-nm diameter FeCo tip integrated onto the wire produces field gradients greater than 10^5 T/m at the same position. The large rf fields from the broadband microwire enable long rotating-frame spin lifetimes of up to 15 s at 4 K.
△ Less
Submitted 7 May, 2007; v1 submitted 3 May, 2007;
originally announced May 2007.