On the coupling of magnetic moments to superconducting quantum interference devices
Authors:
J. Linek,
M. Wyszynski,
B. Müller,
D. Korinski,
M. V. Milošević,
R. Kleiner,
D. Koelle
Abstract:
We investigate the coupling factor $φ_μ$ that quantifies the magnetic flux $Φ$ per magnetic moment $μ$ of a point-like magnetic dipole that couples to a superconducting quantum interference device (SQUID). Representing the dipole by a current-carrying loop, the reciprocity of mutual inductances of SQUID and loop provides a way of calculating $φ_μ(\vec{r}, \vec{e}_μ)$ vs.~position $\vec{r}$ and ori…
▽ More
We investigate the coupling factor $φ_μ$ that quantifies the magnetic flux $Φ$ per magnetic moment $μ$ of a point-like magnetic dipole that couples to a superconducting quantum interference device (SQUID). Representing the dipole by a current-carrying loop, the reciprocity of mutual inductances of SQUID and loop provides a way of calculating $φ_μ(\vec{r}, \vec{e}_μ)$ vs.~position $\vec{r}$ and orientation $\vec{e}_μ$ of the dipole anywhere in space from the magnetic field $B(\vec{r})$ produced by a supercurrent circulating in the SQUID loop. We use numerical simulations based on London and Ginzburg-Landau theory to calculate $φ_μ$ from the supercurrent density distributions in various SQUID geometries. We treat the far-field regime ($r\gtrsim a=$ inner size of the SQUID loop) with the dipole placed on the symmetry axis of circular or square shaped loops. We compare expressions for $φ_μ$ from filamentary loop models with simulation results for loops with finite width $w$ (outer size $A>a$), thickness $d$ and London penetration depth $λ_L$ and show that for thin ($d\ll a$) and narrow ($w < a$) loops the introduction of an effective loop size $a_{\rm eff}$ in the filamentary loop-model expressions results in agreement with simulations. For a dipole placed in the center of the loop, simulations provide an expression $φ_μ(a,A,d,λ_L)$ that covers a wide parameter range. In the near-field regime (dipole centered at small distance $z$ above one SQUID arm) only coupling to a single strip representing the SQUID arm has to be considered. Here, we compare simulations with an analytical expression derived for a homogeneous current density distribution, which yields excellent agreement for $λ_L>w,d$. Moreover, we analyze $φ_μ$ provided by the introduction of a constriction in the SQUID arm below the magnetic dipole.
△ Less
Submitted 11 July, 2023;
originally announced July 2023.
NanoSQUID magnetometry of individual cobalt nanoparticles grown by focused electron beam induced deposition
Authors:
M. J. Martínez-Pérez,
B. Müller,
D. Schwebius,
D. Korinski,
R. Kleiner,
J. Sesé,
D. Koelle
Abstract:
We demonstrate the operation of low-noise nano superconducting quantum interference devices (SQUIDs) based on the high critical field and high critical temperature superconductor YBa$_2$Cu$_3$O$_7$ (YBCO) as ultra-sensitive magnetometers for single magnetic nanoparticles (MNPs). The nanoSQUIDs exploit the Josephson behavior of YBCO grain boundaries and have been patterned by focused ion beam milli…
▽ More
We demonstrate the operation of low-noise nano superconducting quantum interference devices (SQUIDs) based on the high critical field and high critical temperature superconductor YBa$_2$Cu$_3$O$_7$ (YBCO) as ultra-sensitive magnetometers for single magnetic nanoparticles (MNPs). The nanoSQUIDs exploit the Josephson behavior of YBCO grain boundaries and have been patterned by focused ion beam milling. This allows to precisely define the lateral dimensions of the SQUIDs so as to achieve large magnetic coupling between the nanoloop and individual MNPs. By means of focused electron beam induced deposition, cobalt MNPs with typical size of several tens of nm have been grown directly on the surface of the sensors with nanometric spatial resolution. Remarkably, the nanoSQUIDs are operative over extremely broad ranges of applied magnetic field (-1 T $< μ_0 H <$ 1 T) and temperature (0.3 K $< T<$ 80 K). All these features together have allowed us to perform magnetization measurements under different ambient conditions and to detect the magnetization reversal of individual Co MNPs with magnetic moments (1 - 30) $\times 10^6\,μ_{\rm B}$. Depending on the dimensions and shape of the particles we have distinguished between two different magnetic states yielding different reversal mechanisms. The magnetization reversal is thermally activated over an energy barrier, which has been quantified for the (quasi) single-domain particles. Our measurements serve to show not only the high sensitivity achievable with YBCO nanoSQUIDs, but also demonstrate that these sensors are exceptional magnetometers for the investigation of the properties of individual nanomagnets.
△ Less
Submitted 28 October, 2016;
originally announced October 2016.