The Heisenberg-RIXS instrument at the European XFEL
Authors:
Justine Schlappa,
Giacomo Ghiringhelli,
Benjamin E. Van Kuiken,
Martin Teichmann,
Piter S. Miedema,
Jan Torben Delitz,
Natalia Gerasimova,
Serguei Molodtsov,
Luigi Adriano,
Bernard Baranasic,
Carsten Broers,
Robert Carley,
Patrick Gessler,
Nahid Ghodrati,
David Hickin,
Le Phuong Hoang,
Manuel Izquierdo,
Laurent Mercadier,
Giuseppe Mercurio,
Sergii Parchenko,
Marijan Stupar,
Zhong Yin,
Leonardo Martinelli,
Giacomo Merzoni,
Ying Ying Peng
, et al. (22 additional authors not shown)
Abstract:
Resonant Inelastic X-ray Scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. And in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advant…
▽ More
Resonant Inelastic X-ray Scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. And in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high repetition rate pulsed X-ray sources like the European XFEL. The hRIXS instrument is designed for RIXS experiments in the soft X-ray range with energy resolution approaching the Fourier and the Heisenberg limits. It is based on a spherical grating with variable line spacing (VLS) and a position-sensitive 2D detector. Initially, two gratings are installed to adequately cover the whole photon energy range. With optimized spot size on the sample and small pixel detector the energy resolution can be better than 40 meV at any photon energy below 1000 eV. At the SCS instrument of the European XFEL the spectrometer can be easily positioned thanks to air-pads on a high-quality floor, allowing the scattering angle to be continuously adjusted over the 65-145 deg range. It can be coupled to two different sample interaction chamber, one for liquid jets and one for solids, each equipped at the state-of-the-art and compatible for optical laser pum** in collinear geometry. The measured performances, in terms of energy resolution and count rate on the detector, closely match design expectations. hRIXS is open to public users since the summer of 2022.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.
Megahertz-rate Ultrafast X-ray Scattering and Holographic Imaging at the European XFEL
Authors:
Nanna Zhou Hagström,
Michael Schneider,
Nico Kerber,
Alexander Yaroslavtsev,
Erick Burgos Parra,
Marijan Beg,
Martin Lang,
Christian M. Günther,
Boris Seng,
Fabian Kammerbauer,
Horia Popescu,
Matteo Pancaldi,
Kumar Neeraj,
Debanjan Polley,
Rahul Jangid,
Stjepan B. Hrkac,
Sheena K. K. Patel,
Sergei Ovcharenko,
Diego Turenne,
Dmitriy Ksenzov,
Christine Boeglin,
Igor Pronin,
Marina Baidakova,
Clemens von Korff Schmising,
Martin Borchert
, et al. (75 additional authors not shown)
Abstract:
The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence, and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, we presen…
▽ More
The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence, and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, we present the results from the first megahertz repetition rate X-ray scattering experiments at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL. We illustrate the experimental capabilities that the SCS instrument offers, resulting from the operation at MHz repetition rates and the availability of the novel DSSC 2D imaging detector. Time-resolved magnetic X-ray scattering and holographic imaging experiments in solid state samples were chosen as representative, providing an ideal test-bed for operation at megahertz rates. Our results are relevant and applicable to any other non-destructive XFEL experiments in the soft X-ray range.
△ Less
Submitted 20 January, 2022; v1 submitted 17 January, 2022;
originally announced January 2022.